T105 - High accuracy GPS time server
8Pages

{{requestButtons}}

Catalog excerpts

T105 - High accuracy GPS time server - 1

DATA SHEET T105, very high precision Time Server NTP/SNTP Time server / GPS Primary Clock, with PoE and advanced I/O synchronization features. - Static applications - 1 Bd d’Armor – 22300 LANNION - FRANCE contact@heoldesign.com © 2015 All Rights Reserved. All specifications subject to change without Notic

Open the catalog to page 1
T105 - High accuracy GPS time server - 2

DATA SHEET HEOL-T105: HIGH ACCURACY SYNCHRONIZATION UNIT The T105 Time server / GPS Clock has been designed to provide very accurate timing information trough an Ethernet link (using NTP/SNTP protocol), for Network synchronization and measurement applications, without the need to be connected to external Network, hence preserving your Network insulation. It is dedicated only to static applications. Based on a high performance 14 channels GPS timing chipset (with -160dBm sensitivity), it delivers extremely accurate timing information, even in poor signal level conditions (indoor, urban...

Open the catalog to page 2
T105 - High accuracy GPS time server - 3

DATA SHEET A web server with secure access allows you to configure the HEOL-T105, and monitor its status at a glance (GPS satellites strength signals, Ethernet connections, alarms, input/outputs…). Automatic E-mails can be sent by the HEOL-T105, periodically or when alarms appear. This function is fully configurable via the http server. A 2500V isolated event input allows you to time-stamp events from external systems, with very high accuracy (±100 nanoseconds, refer to UTC atomic clock). The TimeStamp information is reported through RS232, SNMP trap, E-mail or Broadcast frame. A second...

Open the catalog to page 3
T105 - High accuracy GPS time server - 4

DATA SHEET GPS antenna Remote interface +NMEA Clock generator OCXO/TCXO Event inputs External Events Sync outputs User systems NTP/SNTP (synchro and events) http (config) SNMP (alarms and events) SMTP (E-mail) Automated systems T105 synoptic and external links 1 Bd d’Armor – 22300 LANNION - FRANCE contact@heoldesign.com © 2015 All Rights Reserved. All specifications subject to change without Notic

Open the catalog to page 4
T105 - High accuracy GPS time server - 5

HEOL DESIGN 1 Bd d'Armor - 22300 LANNION - FRANCE contact@heoldesign.com © 2015 All Rights Reserved. All specifications subject to change without Notice.

Open the catalog to page 5
T105 - High accuracy GPS time server - 6

Note : Heol Design is not responsible for the operation or failure of operation of GPS satellites or the availability of GPS satellite signals. ■ According to v ^ directive, the T105 module has passed the following tests : > EN55022/55011 class B : conducted and radiated emissions. > EN61000-4-2: Immunity to electrostatic discharges. > EN61000-4-3: Immunity tests on electromagnetic fields radiated at radio-electrical frequencies, with 10V/m electromagnetic field. > EN61000-4-4: Immunity to rapid transients. > EN61000-4-5: Immunity to surge. > EN61000-4-6: Immunity tests on conducted...

Open the catalog to page 6
T105 - High accuracy GPS time server - 7

DATA SHEET T105 19’’ 1U Rack rear view (with ‘N’ antenna connector) 3&4 pins : Alarm relay or PPS/TOP output on Static relay (option PPSREL) 1&2 pins : Event input #1 5&6 pins : PPS/TOP RS422 output or IRIG B003 output (option IRIG) or Event input #2 (option EVENT2) 1 Bd d’Armor – 22300 LANNION - FRANCE contact@heoldesign.com © 2015 All Rights Reserved. All specifications subject to change witho

Open the catalog to page 7
T105 - High accuracy GPS time server - 8

ORDERING PART NUMBER accuracy 10js 100js 1ms • Power DC : 14 to 60V DC/POE: DC+Power Ethernet AC : 110 to 250V (Rack only) • I/O option I/O connector mounted (blank : not mounted) • OCXO option — OCXOSR : standard (0 / +50°C) OCXOMR : medium (-20 / +65°C) OCXOHR : high (-40 / +70°C) • RTC option : for fast start without GPS satellites If other options are needed, just add the part number of these options at the end of the T105 part number : -422 for RS422 serial port instead of RS232 -EVENT2 for secondary Event input -IRIG for IRIG-B003 output -PPSREL for PPS/TOP output on fast static...

Open the catalog to page 8

All Heol design catalogs and technical brochures

  1. N016-v2

    6 Pages

  2. wck004

    10 Pages

  3. HD wck002

    2 Pages

  4. N105-US-6000

    12 Pages

  5. TS2100

    4 Pages

  6. N101

    6 Pages

  7. T116

    9 Pages

  8. N105

    3 Pages

  9. T102

    7 Pages

  10. T101

    8 Pages

  11. T108

    8 Pages

  12. N016

    8 Pages