Introduction
HEOL DESIGN has developed a series of GPS receiver clone boards based on the Copernicus II high-performance GPS chipset. These boards are designed for embedded and industrial applications requiring precise positioning and timing, serving as replacements for the now obsolete Trimble Lassen iQ, SQ, LP, SK2, and ACE (ACEII, ACEIII) receiver boards.
Key Features
  • Ultra-high sensitivity of -160dBm for effective performance in challenging environments.
  • Support for SBAS (WAAS, EGNOS) to enhance horizontal and altitude accuracy.
  • Quick Cold Start Time to First Fix (TTFF) of less than 38 seconds.
  • Low power consumption of approximately 100mW.
  • Configurable serial ports for various protocols and transmission speeds.
  • EEPROM-backed configuration parameters.
  • Pin-to-pin compatibility with Trimble GPS receivers for easy integration.
  • Protection against antenna open/short circuits and overvoltage.
  • Accurate pulse per second (pps) signal with precision better than ±60 ns.
  • Optional onboard backup capacitor for 30-hour hot start-up autonomy.
Performance Specifications
  • 12-channel receiver with update speed of 1Hz for TSIP and NMEA.
  • Horizontal accuracy with SBAS: <2 meters (50%), <4 meters (90%).
  • Altitude accuracy with SBAS: <3 meters (50%), <5 meters (90%).
  • Speed accuracy: 0.06 m/sec (nominal).
  • Initial acquisition times: Cold < 39s, Warm < 35s, Hot < 3s.
  • Reacquisition time after signal loss: < 2 seconds.
  • Operational altitude up to 18,000 meters and speed up to 515 m/sec.
  • Operating temperature range: -40/+85 °C; Storage: -55/+105°C.
Electrical Characteristics
  • Prime power voltage: 3.2 to 5.5 VDC; Power consumption: 100mW.
  • Backup power voltage: 3.2 to 3.6 VDC; Power consumption: 10µA.
  • Antenna voltage: 3 to 5 VDC, switch selectable.
EMC Compatibility
  • Compliance with EN55022 class B, EN61000-4-3, EN61000-4-6, EN61000-4-4, and EN61000-4-2 standards.
Ordering Information
  • Lassen SK2 replacement: N011-V1-B (parity 'none'), N021-V1-B (parity 'odd').
  • Lassen LP replacement: N013-V1-X C.
  • ACEII/ACEIII replacement: N014-V1-B (parity 'none'), N024-V1-B (parity 'odd').
  • Lassen iQ/SQ replacement: N016-V1-H C R.
  • Antenna connectors: SMB, SMA, MCX, Fakra SMB, Hirose HFL.
  • Optional backup battery capacitor available.
See more

Catalog excerpts

N0xx, TRIMBLE Lassen SK2 / iQ / sQ / LP replacements clone boards-1

HEOL DESIGNN0xx, improved replacement GPS receivers : clones for Trimble iQ, SQ, SK2, LP, ACE II/IIIN016HEOL DESIGN P/N : N016-V1 -HS HEOL DESIGN

 Open the catalog to page 1
N0xx, TRIMBLE Lassen SK2 / iQ / sQ / LP replacements clone boards-2

BEST PERFORMANCE HEOL DESIGN is the first company to produce Trimble GPS receiver clone boards, which are based on the Copernicus II high performance GPS chip set. These OEM board are designed for use in embedded and industrial applications requiring high accuracy positioning and timing information. They can also be used as a replacement and upgrade for users of the Trimble Lassen iQ, SQ, LP, SK2 and ACE (ACEII, ACEIII) receiver boards, which are now EOL (end of life). The N0xx (except N016 - iQ and SQ replacement boards), have an additional feature: thanks to a switch, you can select the active...

 Open the catalog to page 2
N0xx, TRIMBLE Lassen SK2 / iQ / sQ / LP replacements clone boards-3

EMC compatibility The HEOL-NOxx boards have successfully completed compliance testing against the following standards listed below: (In accordance with the C€ directive). > EN55022 class B (conducted and radiated emissions) dated January 1999, with 10dB margin. > EN61000-4-3 published in 2002: "Immunity tests on electromagnetic fields radiated at radio-electrical frequencies", with 10V/m electromagnetic field. > EN61000-4-6 published in February 1997: "Immunity tests on conducted interference, induced by radio-electrical fields". > EN61000-4-4 (Immunity to rapid transients) dated June 1995, with...

 Open the catalog to page 3
N0xx, TRIMBLE Lassen SK2 / iQ / sQ / LP replacements clone boards-4

Ordering part numbers Lassen SK2 replacement board: N011-V1-B with parity 'none' N021-V1-B with parity 'odd' Lassen LP replacement board: N013-V1-X C ACEII / ACEIII replacement board: N014-V1-B with parity 'none' N024-V1-B with parity 'odd' For these 3 part numbers : Antenna connector: • B : SMB (default) • A : SMA • X : MCX • F : Fakra SMB C : Optional BackUp Battery Capacitor (leave blank if not required) Lassen iQ / SQ replacement board: N016-V1-H C R Antenna connector: • H : Hirose HFL (default) • A : SMA on cable Fixing pins: • R : Right angle (default) • S : Straight C : Optional on board...