Catalog excerpts
DK-Cable junction boxes tested for functional integrity in the event of fire Functional integrity in accordance with DIN 4102 part 12 (german standard) ated connecting capacity 0.5-16 mm² R Boxes made from duroplastic or sheet steel with powder coating Gustav Hensel GmbH & Co. KG Industrial Electrical Power Distribution Systems Altenhundem Gustav-Hensel-Straße 6 D-57368 Lennestadt Germany Phone: +49 2723/609-0 Fax: +49 2723/60052 E-mail: info@hensel-electric.de www.hensel-electric.de Industrial Electrical Power Distribution Systems
Open the catalog to page 1DK Cable junction boxes tested for functional integrity in the event of fire cable entry via included grommets degree of protection IP 65 rated insulation voltage AC/DC400 V connecting terminal made from ceramic with resistance to high temperatures 2 attached universal anchors, fire protection tested material: Duroplastic colour orange RAL 2003 Connection box for 2 cables Ø 0,8 mm / 0,5-4 mm², Cu Junction box Ø 0,8 mm / 0,5-1,5 mm², Cu 5-pole, per pole 4 x Ø 0,8 mm / 0,5 mm² sol, 4 x 1,5 mm² sol, 2 x 2,5 mm² sol, 2 x 4 mm² sol, included cable entry 4 EDKF 32 (sealing range: Ø 8-23 mm)...
Open the catalog to page 2DK Cable junction boxes tested for functional integrity in the event of fire cable entry via mounted grommets degree of protection IP 65 rated insulation voltage AC/DC400 V connecting terminal made from ceramic with resistance to high temperatures 4 mounted grommets IP 65, closed material: sheet steel, powder-coated colour orange, RAL 2003 mounted using exterior wall fixings (for dowels refer to technical data) Connection box for 2 cables Ø 0,8 mm / 0,5-4 mm², Cu Junction box Ø 0,8 mm / 0,5-1,5 mm², Cu 5-pole, per pole 4 x Ø 0,8 mm / 0,5 mm² sol, 4 x 1,5 mm² sol, 2 x 2,5 mm² sol, 2 x 4 mm²...
Open the catalog to page 3DK Cable junction boxes tested for functional integrity in the event of fire cable entry via mounted grommets cable junction box with fused outgoing unit functional integrity E 30 following DIN 4102 part 12 degree of protection IP 65 rated insulation voltage AC400 V terminal block made from ceramic with resistance to high temperatures D 01 neozed fuse base material: sheet steel, powder-coated colour orange, RAL 2003 4 mounted grommets IP 65, closed mounted using exterior wall fixings (for dowels refer to technical data) 5-pole, 2 connecting terminals 2 junction terminals 2 PE terminals each...
Open the catalog to page 4DK Cable junction boxes with functional integrity in the event of fire Connection of cables and wires for operation and functional integrity in the event of fire: Functional integrity for installation systems Functional integrity in accordance with DIN 4102 part 12 is required for safety-related circuits, such as the power supply for safety lighting, firemen‘s lifts, fire alarm systems, ventilation and smoke exhaust systems and pumps in sprinkler systems. Therefore the circuits that are affected are those which are important in the event of fire for rescuing people or for fire fighting....
Open the catalog to page 5DK Cable junction boxes tested for functional integrity in the event of fire Application areas Hensel FK Boxes are suitable for the use in applications like for instance: Power plants Metro Railways Car tunnels Hotels Hospitals Airports Banks Petrol stations Industry Public buildings
Open the catalog to page 6All Hensel catalogs and technical brochures
-
D 9025
3 Pages
-
Load Centers up to 250 A
17 Pages
-
A company and its products
24 Pages
-
ENYLOGIC - Energy Management
1 Pages
-
International catalog
400 Pages
-
Product Innovations 2014
11 Pages
-
Tunnel Box
4 Pages
-
ENYFIT - Cable entry systems
28 Pages
-
ENYCASE - DK Cable junction boxes
120 Pages