Product catalog summary
System Description and Specifications
The ENYSTAR distribution boards are designed for use up to 250 A, compliant with IEC 61 439-3 standards, and suitable for operation by ordinary persons. The enclosures are made from polycarbonate, offering protection class II and IP 65 rating, making them dust-proof and water-resistant. They are suitable for indoor and protected outdoor installations, withstanding temperatures from -5°C to 40°C for distribution boards and -25°C to 70°C for empty enclosures.
Design and Assembly
The system features a modular enclosure system that allows for easy assembly and expansion. Enclosures come in four sizes and can be combined vertically or horizontally. The design includes transparent or opaque doors with changeable hinges and lockable features for safety and ease of operation.
Product Benefits
ENYSTAR offers empty enclosures and circuit breaker boxes with doors, available in transparent or opaque options. They are designed for easy operation by both skilled and unskilled persons, with tool-operated doors for restricted access areas.
Technical Details
The distribution boards are made from high-quality thermoplastic material, providing high mechanical strength (IK 08) and resistance to corrosion, UV, and chemicals. They are flame-retardant and self-extinguishing, meeting the glow wire test at 960°C.
Applications and Recommendations
These distribution boards are ideal for commercial and industrial applications, offering robust protection and flexibility in harsh environments. They ensure clear separation between operation and distribution areas, with specific access requirements for electrical skilled persons.
Accessories and Additional Information
A range of accessories is available to complement the ENYSTAR enclosures, including DIN rails, mounting plates, and closing plate sets. Further details and additional electrical functions can be found on the manufacturer's website.
Specifications
  • Protection Rating: IP 44 for ventilation inserts and IP 65 for cable inserts with additional strain relief.
  • Material Properties: Halogen-free and silicone-free, flame-retardant, and self-extinguishing as per IEC 60 695-2-11 and UL Subject 94.
  • Mechanical Load Protection: IK 08 (5 Joule).
Accessories
  • Closing Plates: Available for various box sizes with specific dimensions and fixing elements.
  • Metal Inserts: For earthing metal armoured cables, available for specific box sizes.
  • Flanges: Various types with different sealing ranges and knockouts for cable entry.
  • Canopies and Connectors: For connecting enclosures and sealing doors.
Technical Details
  • Operating Conditions: Suitable for indoor and protected outdoor installations with specific ambient temperature ranges.
  • Fire Protection: Glow wire test requirements for boxes and conducting components.
  • Standards Compliance: ENYSTAR distribution boards comply with IEC 61 439-3, IEC 60 999, DIN EN 50 262, and other relevant standards.
Assembly Instructions
  • Enclosure Assembly: Fast assembly with connectors and wall separators, ensuring IP 65 protection.
  • Wall Mounting: Use of stainless steel external brackets and mounting profiles for secure installation.
  • Cable Entry: Flanges and closing plates are used for sealing and cable management.
Power Dissipation
Guidelines for calculating maximum permissible power dissipation and operating temperature inside enclosures based on ambient conditions and equipment specifications.
Device Installation into Covers
Pre-drill and saw out cut-outs using a piercing saw with coarse-toothed blades suitable for plastics. Install devices into the prepared covers.
Device Mounting
Devices can be mounted on plates using self-threading screws or on DIN rails, which can be directly mounted or elevated using spacers. The cover is attached to the door-frame from the rear, and the assembly is secured to the enclosure base.
Sealing
Sealing devices are installed in all enclosures except those for DIN rail-mounted devices. The sealing device is screwed onto the enclosure bottom, and the cover is secured with the door-frame. PE and N terminals are installed using FIXCONNECT® plug-in technology, with arrow marks indicating the fixing position.
Sealing of Unused Openings
Unused DIN rail openings should be covered with blanking strips to prevent accidental contact. Circuit breaker boxes can accommodate any DIN rail equipment, provided the back-up fuse does not exceed 80 A per row of 12 modules.
See more

Catalog excerpts

ENYSTAR Distribution board up to 250 A with door-1

Distribution Boards up to 250 A with Door According to IEC 61 439-3 „Distribution Boards Intended to be Operated by Ordinary Persons (DBO)“ - combinable enclosure system - degree of protection IP 65 - made from polycarbonate - protection class II, Ɓ - in accordance with IEC 61 439 Part 3 Assembly video Design fast, simply, more clever www. .eu

 Open the catalog to page 1
ENYSTAR Distribution board up to 250 A with door-2

ENYSTAR Contents System description / Enclosure system System design / Assembly examples Distribution boards up to 250 A according to IEC 61 439-3, ”intended to be operated by ordinary persons“ Product benefits: Empty enclosures and circuit breaker boxes with doors Empty enclosures with transparent doors Empty enclosures with opaque doors Circuit breaker boxes for installation of DIN rail equipment up to 63 A with PE and N terminals, 9 up to 54 modules without PE and N terminals, 12 up to 51 modules Circuit breaker boxes for installation of DIN rail equipment up to 63 A with removable DIN rail...

 Open the catalog to page 2
ENYSTAR Distribution board up to 250 A with door-3

ENYSTAR System Description Enclosure System Ambient temperature Environmental conditions The ambient temperature for distribution boards is reduced by the installed equipment technology! Application area The enclosures are suitable for the protected outdoor installation harsh environment and / or protected outdoor. However the climatic inuences and effects on the equipment are to be considered. Insulated enclosures (Protection class II) Ɓ Impact strength degree of protection against mechanical load IK 08 (5 Joule) in accordance with IEC 62 262 Protection against foreign solid objects and direct...

 Open the catalog to page 3
ENYSTAR Distribution board up to 250 A with door-4

System Description Combinable enclosure system with doors Easy operation of the devices behind a door with protection against accidentia! contact. Distribution Boards up to 250 A with Door combinable enclosure system degree of protection IP 65, made from polycarbonate Distribution Boards up to 250 A with Door ■ for indoor and protected outdoor installation ■ dust-proof and protected against water (IP 65) ■ all enclosure sizes with door ■ door hinge changeable ■ locking facilities: lockable, door fasteners for tool and hand operation ■ operation of the devices behind the door protected with covers,...

 Open the catalog to page 4
ENYSTAR Distribution board up to 250 A with door-5

g^j-^j ENYSTAR enVSTQP* System Design Combinable distribution boards with door ■ modular structure of enclo- ■ to assemble fast and simply ■ Order closing plate sets, single closing plates Standard enclosure Extension frame for extending Combinable enclosures with door circuit breaker boxes additionally with closing plate sets for closing enclosure walls Enclosure walls closed via closing plates effected via wall symbols that are assigned to each product. The individual figures [J] give an indication, which wall is Distribution boards Wall opening: Wall opening: Wall opening: Wall opening:

 Open the catalog to page 5
ENYSTAR Distribution board up to 250 A with door-6

ENYSTAR System Design Assembly Examples Can be combined and extended in all directions Because of the increasing requirements, exibility is essential in the electrial installation. ENYSTAR enclosures can be combined and arranged freely in Combination of enclosures in vertical direction. Distribution boards intended to be operated by ordinary persons order to adapt the system exibly to the individual requirements in site: Combination next to each other or one above the other. Combination of enclosures in horizontal direction. Example 1: Distribution board with 72 modules (6 x 12 x 18 mm) built-up...

 Open the catalog to page 6
ENYSTAR Distribution board up to 250 A with door-7

ENYSTAR Assembly Examples

 Open the catalog to page 7
ENYSTAR Distribution board up to 250 A with door-8

ENYSTAR Distribution Boards up to 250 A According to IEC 61 439-3 „Distribution Boards Indended to Be Operated by Ordinary Persons“ Distribution boards are usually used in working place proximity. Their application is various. Here the demands and requirements that result from the installation site must be adhered to. General requirements concerning distribution boards 1. Clear separation between operation area and distribution area For areas in distribution boards to which unskilled persons have access, standards require special protective measures: - Life parts are to be protected against accidental...

 Open the catalog to page 8
ENYSTAR Distribution board up to 250 A with door-9

ENYSTAR Empty Enclosures Circuit Breaker Boxes Zuordnung der Gehäusewände Die Zuordnung der Gehäusewände erfolgt über die Wandsymbole, die jedem Produkt zugewiesen sind. Die einzelnen Zahlen 1 geben den Hinweis, um welche Wand es sich handelt. doors in areas to which unskilled persons have access for operating devices mounting via mounting plates doors in areas to which only an electrical skilled person may have access device installation into covers for earth connection according to British Standard

 Open the catalog to page 9
ENYSTAR Distribution board up to 250 A with door-10

Empty Boxes with Transparent Door Access and Operation Only by Skilled Persons Built-in dimensions ■ max. installation depth with built-in mounting plate 136 mm, with built-in DIN rail 125 mm ■ with transparent door ■ door fastener with tool operation ■ door locking sealable ■ please order DIN rails, mounting plates or covers additionally ■ order closing plate sets, single closing plates and flanges separately Built-in dimensions with closing plates for box walls ■ max. installation depth with built-in mounting plate 136 mm, with built-in DIN rail 125 mm ■ with transparent door ■ door fastener...

 Open the catalog to page 10
ENYSTAR Distribution board up to 250 A with door-11

Empty Boxes with Transparent Door Access and Operation Only by Skilled Persons Built-in dimensions ■ max. installation depth with built-in mounting plate 136 mm, with built-in DIN rail 125 mm ■ with transparent door ■ door fastener with tool operation ■ door locking sealable ■ please order DIN rails, mounting plates or covers additionally ■ order closing plate sets, single closing plates and flanges separately Built-in dimensions with closing plates for box walls ■ max. installation depth with built-in mounting plate 136 mm, with built-in DIN rail 125 mm ■ with transparent door ■ door fastener...

 Open the catalog to page 11
ENYSTAR Distribution board up to 250 A with door-12

Empty Boxes with Transparent Door Access and Operation Only by Skilled Persons Built-in dimensions with closing plates for box walls ■ max. installation depth with built-in mounting plate 136 mm, with built-in DIN rail 125 mm ■ with transparent door ■ door fastener with tool operation ■ door locking sealable ■ please order DIN rails, mounting plates or covers additionally ■ order flanges separately

 Open the catalog to page 12
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.