1. Catalogs
  2. Hensel
  3. ENYFIT - Cable entry systems
video corpo
cad

ENYFIT - Cable entry systems

ENYFIT - Cable entry systems
1 / 28 PagesView full catalog

ENYFIT - Cable entry systems

Product catalog summary
Overview: The document provides comprehensive technical specifications and guidelines for various cable entry systems, including grommets and cable glands, designed for both indoor and outdoor installations, particularly in harsh environments. It outlines the dimensions, sealing ranges, and suitable environmental conditions for each product type.
Grommets:
  • ESM Series (IP 55): Suitable for indoor and protected outdoor installations, made from TPE, available in sizes for knockouts M16 to M40, with a sealing range from Ø 4.8 mm to Ø 30 mm, and temperature resistance from -25°C to +35°C.
  • STM Series (IP 55): Stepped grommets with sealing ranges from Ø 3.5 mm to Ø 34 mm, suitable for similar environments as the ESM series.
  • EDK Series (IP 65): Offers higher protection for demanding environments, with sealing ranges from Ø 5 mm to Ø 30 mm.
  • EDR Series (IP 65): Designed for conduit connections, available for knockouts M16 to M40.
Cable Glands:
  • AKM Series (IP 65): Made from PA, suitable for both indoor and outdoor installations, with sealing ranges from Ø 4 mm to Ø 48 mm, including strain relief and locknut.
  • ASM Series (IP 66): Provides enhanced protection with a glow wire test rating of 960°C, suitable for harsh environments.
  • AFM Series (IP 65): Can be mounted without a locknut, useful for installations where space is limited.
  • ASS Series (IP 66/67): Offers the highest level of protection, suitable for both indoor and outdoor use.
Key Specifications:
  • All products are tested according to IEC 60 695-2-11 standards.
  • Ambient temperature ranges from -25°C to +55°C depending on the product.
  • Materials used include TPE and PA, with color codes RAL 7035 and RAL 9005.
Applications: These systems are designed for use in various environments, from normal indoor settings to harsh outdoor conditions, providing flexibility and reliability in cable management solutions.
Additional Components:
  • Combi Climate Glands: Integrate cable entry and ventilation to prevent humidity ingress and condensation, maintaining enclosure protection up to IP67.
  • Pressure Compensation Elements: Designed for M32 knockouts, reduce condensation through pressure compensation, suitable for enclosure volumes up to 42 litres per element.
  • Sealing Plugs: Used to seal unused combi climate glands, available in diameters 13 mm and 21 mm.
Technical Details:
  • Includes tables assigning cable outside diameters to cable entries, with specific dimensions for each type of grommet and gland.
  • Operating conditions specify ambient temperatures and fire protection standards, including glow wire tests and flame-retardant properties.
  • Materials are halogen-free and silicone-free, adhering to IEC standards for safety and environmental compliance.
Dimensions and Installation:
  • Detailed dimensions for grommets and glands are provided, including specific measurements for insertion into knockouts without the need for a counternut.
  • Products are suitable for retrofitting onto boxes made of sheet steel with specified material thickness.
Conclusion: The document provides comprehensive specifications for selecting and installing cable entry systems, ensuring protection against environmental factors while maintaining functionality and safety standards.
See more

Catalog excerpts

ENYFIT - Cable entry systems-1

LES Cable Entry Systems LES Cable Entry Systems Grommets ESM, IP 54 Cable glands AFM without locknut, IP 65 Combi climate glands, IP 66/67 Pressure compensation element Stepped grommets, ange, cable retention

 Open the catalog to page 1
ENYFIT - Cable entry systems-2

LES Cable Entry Systems ■ for indoor - normal environment and (or) protected outdoor installation ■ glow wire test IEC 60 695-2-11: 750° C ■ for indoor - normal environment and (or) protected outdoor installation ■ glow wire test IEC 60 695-2-11: 750° C ■ for indoor - normal environment and (or) protected outdoor installation ■ glow wire test IEC 60 695-2-11: 750° C ■ for indoor - normal environment and (or) protected outdoor installation ■ glow wire test IEC 60 695-2-11: 750° C ■ for indoor - normal environment and (or) protected outdoor installation ■ glow wire test IEC 60 695-2-11: 750° C

 Open the catalog to page 2
ENYFIT - Cable entry systems-3

LES Cable Entry Systems Stepped Grommets STM 16 Stepped grommet for knockouts M 16 range: Ø 3,5-12 mm Ø 16.5 mm wall thickness 1.5-4 mm for indoor - normal environment and (or) protected outdoor installation ambient temperature - 25° to + 35° C glow wire test IEC 60 695-2-11: 750° C bore-hole: STM 20 Stepped grommet for knockouts M 20 range: Ø 5-16 mm Ø 20.5 mm wall thickness 1.5-4 mm for indoor - normal environment and (or) protected outdoor installation ambient temperature - 25° to + 35° C glow wire test IEC 60 695-2-11: 750° C bore-hole: STM 25 Stepped grommet for knockouts M 25 range: Ø 5-21...

 Open the catalog to page 3
ENYFIT - Cable entry systems-4

LES Cable Entry Systems ■ for indoor - normal environment and (or) protected outdoor installation ■ glow wire test IEC 60 695-2-11: 750°C ■ for indoor - normal environment and (or) protected outdoor installation ■ glow wire test IEC 60 695-2-11: 750° C ■ for indoor - normal environment and (or) protected outdoor installation ■ glow wire test IEC 60 695-2-11: 750° C ■ for indoor - normal environment and (or) protected outdoor installation ■ glow wire test IEC 60 695-2-11: 750° C ■ for indoor - normal environment and (or) protected outdoor installation ■ glow wire test IEC 60 695-2-11: 750° C

 Open the catalog to page 4
ENYFIT - Cable entry systems-5

LES Cable Entry Systems ■ for indoor - normal environment and (or) protected outdoor installation ■ glow wire test I EC 60 695-2-11: 750°C ■ for indoor - normal environment and (or) protected outdoor installation ■ glow wire test IEC 60 695-2-11: 750°C ■ for indoor - normal environment and (or) protected outdoor installation ■ glow wire test IEC 60 695-2-11: 750°C ■ for indoor - normal environment and (or) protected outdoor installation ■ glow wire test IEC 60 695-2-11: 750°C ■ for indoor - normal environment and (or) protected outdoor installation ■ glow wire test IEC 60 695-2-11: 750°C

 Open the catalog to page 5
ENYFIT - Cable entry systems-6

LES Cable Entry Systems Cable Glands ■ with strain relief and locknut ■ for indoor (normal environment and/or protected outdoor) and outdoor installation (harsh environment and/or outdoor) ■ glow wire test IEC 60 695-2-11: 750°C ■ with strain relief and locknut ■ for indoor (normal environment and/or protected outdoor) and outdoor installation (harsh environment and/or outdoor) ■ glow wire test IEC 60 695-2-11: 750°C ■ with strain relief and locknut ■ for indoor (normal environment and/or protected outdoor) and outdoor installation (harsh environment and/or outdoor) ■ glow wire test IEC 60 695-2-11:...

 Open the catalog to page 6
ENYFIT - Cable entry systems-7

LES Cable Entry Systems Cable Glands ■ with strain relief and locknut ■ for indoor (normal environment and/or protected outdoor) and outdoor installation (harsh environment and/or outdoor) ■ glow wire test IEC 60 695-2-11: 750°C ■ with strain relief and locknut ■ for indoor (normal environment and/or protected outdoor) and outdoor installation (harsh environment and/or outdoor) ■ glow wire test IEC 60 695-2-11: 750°C ■ with strain relief and locknut ■ for indoor (normal environment and/or protected outdoor) and outdoor installation (harsh environment and/or outdoor) ■ glow wire test IEC 60 695-2-11:...

 Open the catalog to page 7
ENYFIT - Cable entry systems-8

LES Cable Entry Systems Cable Glands ■ with strain relief and locknut ■ for indoor (normal environment and/or protected outdoor) and outdoor installation (harsh environment and/or outdoor) ■ glow wire test IEC 60 695-2-11: 960°C ■ with strain relief and locknut ■ for indoor (normal environment and/or protected outdoor) and outdoor installation (harsh environment and/or outdoor) ■ glow wire test IEC 60 695-2-11: 960°C ■ with strain relief and locknut ■ for indoor (normal environment and/or protected outdoor) and outdoor installation (harsh environment and/or outdoor) ■ glow wire test IEC 60 695-2-11:...

 Open the catalog to page 8
ENYFIT - Cable entry systems-9

LES Cable Entry Systems Cable Glands ■ with strain relief and locknut ■ for indoor (normal environment and/or protected outdoor) and outdoor installation (harsh environment and/or outdoor) ■ glow wire test IEC 60 695-2-11: 960°C ■ with strain relief and locknut ■ for indoor (normal environment and/or protected outdoor) and outdoor installation (harsh environment and/or outdoor) ■ glow wire test IEC 60 695-2-11: 960°C ■ with strain relief and locknut ■ for indoor (normal environment and/or protected outdoor) and outdoor installation (harsh environment and/or outdoor) ■ glow wire test IEC 60 695-2-11:...

 Open the catalog to page 9
ENYFIT - Cable entry systems-10

LES Cable Entry Systems Cable Glands ■ the cable gland can be mounted without locknut ■ Especially useful when it is difficult to mount a lock nut in boxes. ■ with strain relief ■ for indoor (normal environment and/or protected outdoor) and outdoor installation (harsh environment and/or outdoor) ■ glow wire test IEC 60 695-2-11: 750° C ■ the cable gland can be mounted without locknut ■ Especially useful when it is difficult to mount a lock nut in boxes. ■ with strain relief ■ for indoor (normal environment and/or protected outdoor) and outdoor installation (harsh environment and/or outdoor) ■...

 Open the catalog to page 10
ENYFIT - Cable entry systems-11

LES Cable Entry Systems Cable Glands ■ with strain relief and locknut ■ for indoor (normal environment and/or protected outdoor) and outdoor installation (harsh environment and/or outdoor) ■ glow wire test IEC 60 695-2-11: 960° C ■ with strain relief and locknut ■ for indoor (normal environment and/or protected outdoor) and outdoor installation (harsh environment and/or outdoor) ■ glow wire test IEC 60 695-2-11: 960° C ■ with strain relief and locknut ■ for indoor (normal environment and/or protected outdoor) and outdoor installation (harsh environment and/or outdoor) ■ glow wire test IEC 60...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.