DK Cable Junction Boxes eOVCflSE' DK Cable Junction Boxes DK Cable junction boxes are VDE tested in accordance with the international standard IEC 60670-22

Open the catalog to page 1
ENYCASE - DK Cable junction boxes - 2

DK Cable Junction Boxes Content Criteria for selecting Box walls With FIXCONNECT® plug-in technology for copper conductors from 1.5 up to 16 mm2 IP 65/IP 55 cable entry via metric knockouts With or without terminals from 1.5 up to 240 mm2 IP 65/IP 55 cable entry via metric knockouts - with terminals for copper conductors - without terminals Box walls without knockouts from 1.5 up to 50 mm2 IP 65 box walls without knockouts, can be drilled individually for customized requirements - without terminals - without terminals, for electrical equipment up to 63 A - Accessories Cable entry via metric...

Open the catalog to page 2
ENYCASE - DK Cable junction boxes - 3

DK Cable Junction Boxes Content "Weatherproof" - for outdoor installation - harsh environment and/or outdoor from 1.5 up to 50 mm2 IP 66 cable/conduit entry via metric knockouts - with / without terminals, colours grey RAL 7032, black RAL 9011 box walls without knockouts - without terminals, colours grey RAL 7032, black RAL 901 "Waterproff" - for outdoor installation - harsh environment and/or outdoor from 1,5 up to 10 mm2 cable entry via metric knockouts - for encapsulating, colours grey RAL 7032, black RAL 9011 NEW "Weatherproof" - for outdoor installation - harsh environment and/or...

Open the catalog to page 3
ENYCASE - DK Cable junction boxes - 4

DK Cable Junction Boxes Criteria for Selecting Functions Branching and connecting of copper conductors Branching and connecting of aluminium and copper conductors In rooms with dry climate In damp and wet environments Protected outdoors (refer to technical details) On ameable parts of buildings In buildings with mainly inammable materials In areas with a high risk of re Cable trunking installation "Weatherproof", for outdoor installation (harsh environment and/or outdoor) Improved behaviour in cases of re ”ame-resistant“ and ”halogen-free“ Offshore applications Security lighting circuits...

Open the catalog to page 4
ENYCASE - DK Cable junction boxes - 5

DK Cable Junction Boxes Criteria for Selecting Connecting solid conductors and stranded conductors Combining multiple control wires to one control cable Main line branch terminals Without terminals Box walls without knockouts Page 56-62 Page 58 K 9501 Pages 107-109 Pages 31-34 all Boxes Pages 73-74, 83-84 Page 91-92 Pages 66-67 Pages 70-71 Pages 73-76

Open the catalog to page 5
ENYCASE - DK Cable junction boxes - 6

DK Cable junction boxes Box Walls Assignment of box walls: The assignment of box walls is effected via wall symbols that are assigned to each product. The individual figures All box walls are listed in the fold-out of the coverpages. which wall is concerned. Wall 23 2 x Elastic membranes Wall 6 2 x M 25/32 Wall 7 2 x M 32 Wall 8 Wall 11 2 x M 20/25 1 x M 32/40 Wall 12 1 x M 20/25 1 x M 25/32 1 x M 40/50 Wall 13 1 x M 20/25 2 x M 40/50

Open the catalog to page 6
ENYCASE - DK Cable junction boxes - 7

DK Cable Junction Boxes with Terminals in Plug-in Technology Cable Entry via Metric Knockouts of space for the wiring: Wiring facilities both below the DIN rails and between the terminals. steel cover screws with quick fastening metric thread. Reducing cover xing time. conductor types - rigid (r) and flexible (f) without treatment of conductors - can be connected in one terminal. system for circuit description template on the Internet at www.hensel-electric.de - in the ’Downloads’ area. can be directly connected and disconnected with installed terminal. behaviour: Glow wire test according...

Open the catalog to page 7
ENYCASE - DK Cable junction boxes - 8

DK Cable Junction Boxes with Terminals in Plug-in Technology Cable Entry via Metric Knockouts plug-in terminal technology per pole 4 x 1 x 1,5-4 mm² sol/f, terminal technology, see annex DK Cable junction boxes included cable entry: 4 ESM 25, sealing range Ø 9-17 mm for normal environment and protected outdoor rated insulation voltage current carrying capacity plug-in terminal technology per pole 4 x 1 x 2.5-10 mm² r/f included cable entry: 3 ESM 32, sealing range Ø 9-23 mm for normal environment and protected outdoor rated insulation voltage current carrying capacity plug-in terminal...

Open the catalog to page 8
ENYCASE - DK Cable junction boxes - 9

DK Cable Junction Boxes Cable Entry via Metric Knockouts terminal mounting positions (5 positions) and new terminal technology accessories as listed: grommets ESM = IP 55 steel cover screws with quick fastening metric thread. Reducing cover xing time. system for circuit description template on the Internet at www.hensel-electric.de - in the ’Downloads’ area. cable junction boxes can in general also be used in poor environmental conditions by using IP 65 cable glands AKM/ASM. behaviour: Glow wire test according to IEC 60 695-2-11: 750 °C / 960 °C, flame-retardant, self-extinguishing

Open the catalog to page 9
ENYCASE - DK Cable junction boxes - 10

DK Cable Junction Boxes Cable Entry via Metric Knockouts terminals per pole 6 x 1.5 mm² sol, 4 x 2.5 mm² sol, 3 x 4 mm² sol included cable entry: 4 ESM 20, sealing range Ø 6-13 mm for normal environment and protected outdoor rated insulation voltage tightening torque for terminal terminals per pole 6 x 1.5 mm² sol, 4 x 2.5 mm² sol, 3 x 4 mm² sol included cable entry: 4 ESM 20, sealing range Ø 6-13 mm with external fixing for normal environment and protected outdoor terminals per pole 6 x 1.5 mm² sol, 4 x 2.5 mm² sol, 3 x 4 mm² sol, 2 x 6 mm² sol included cable entry: 4 ESM 25, sealing range...

Open the catalog to page 10
ENYCASE - DK Cable junction boxes - 11

DK Cable Junction Boxes Cable Entry via Metric Knockouts terminals per pole 6 x 2.5 mm² sol, 4 x 4 mm² sol, 4 x 6 mm² sol, 4 x 10 mm² sol, 2 x 16 mm² s included cable entry: 3 ESM 32, sealing range Ø 9-23 mm for normal environment and protected outdoor rated insulation voltage current carrying capacity tightening torque for terminal terminals per pole 6 x 10 mm² sol, 4 x 16 mm² s, 4 x 25 mm² s, 2 x 35 mm² s included cable entry: 3 ESM 40, sealing range Ø 17-30 mm for normal environment and protected outdoor rated insulation voltage current carrying capacity tightening torque for terminal...

Open the catalog to page 11
ENYCASE - DK Cable junction boxes - 12

DK Cable Junction Boxes Cable Entry via Metric Knockouts terminals per polel 6 x 16 mm² s, 4 x 25 mm² s, 4 x 35 mm² s, 4 x 50 mm² s cable entry via knockouts, order AKM/ASM separately (refer to index cable entry systems) for normal environment and protected outdoor rated insulation voltage current carrying capacity tightening torque for terminal terminals per pole 6 x 16 mm² s, 4 x 25 mm² s, 4 x 35 mm² s, 4 x 50 mm² s cable entries via knockouts order AKM/AKS separately (refer to index LES) for normal environment and protected outdoor rated insulation voltage current carrying capacity...

Open the catalog to page 12