General Overview
The RPCF series reactive power automatic compensation controllers are designed to automatically adjust low voltage distribution system capacitor compensating devices. This adjustment aims to achieve a predetermined power factor, enhance the efficiency of power transformers, reduce line losses, and improve power supply voltage. The controllers operate at a rated working voltage of AC 380V or AC 220V, with a current range of AC 0~5A and a frequency range of 45Hz~65Hz.
Ordering Notes
Users must specify the number of circuits, rated voltage, and type of switch (contactor or combination switch) when ordering. For mixed compensation installations, an RPCF3-16 type reactive power auto-compensation controller is recommended.
Types and Meanings
The controllers are categorized by output type (static or dynamic), total output steps (ranging from 4 to 16), and communication functionality. The RPC designation indicates a reactive power compensation controller.
Normal Working and Installation Conditions
The controllers are suitable for ambient temperatures between -25℃ and +55℃, relative humidity levels of 40% ≤20% and 20% ≤90%, and altitudes up to 2500m. They should be installed in environments free from noxious gases, vapors, conductive or explosive dust, and violent mechanical vibrations.
Main Parameters and Features
The controllers feature high measuring accuracy for power factor, real-time display of total and fundamental wave power factors, and voltage and current distortion rates. They offer 12 output codes for user selection, a maximum of 16 output steps, and a user-friendly interface. Additional features include auto and manual running modes, over-voltage and under-voltage protection, voltage harmonic wave protection, and data retention during power outages. The input impedance for lower current signals is ≤ 0.01Ω.
See more

Catalog excerpts

RPCF series reactive power automatic compensation controllers-1

RPCF series reac�ve power automa�c compensa�on controllers 1 General RPCF series is suitable for automa�cally adjus�ng of low voltage distribu�on sytem capacitor compensa�ng device to make power factor get user’s predetermined state, increase service efficiency of power transformer reduce line loss,and inprove the voltage of power supply. J:sta�c output D:dynamic output Total output steps,The op�onal steps include 4、6、8、10、12、16 steps C:communica�on func�on No mark:no communica�on func�on 3:3-phase mixed compensa�on No mark:three phase compensa�on control physical quan��es F=G+W G:power factor W:reac�ve power RPC indicates reac�ve power compensa�on controller 3 Normal working and installa�on condi�ons 3.1 Ambient temperature:-25℃ ~ +55℃ 3.2 Rela�ve humidity:40℃ ≤20%;20℃ ≤90% 3.3 Al�tude:≤2500m 3.4 Environmental condi�ons: no noxious gas and vapour; no conduc�vity or explosive dust; no violent mechnical vibra�on. 4 Main parameters and other condi�ons rated working voltage rated working current rated Frequency display power factor measuring power measuring active power output contact capacitance dynamic output capacity of every step overall dimension power consumption connection mode Socket connecting terminal screw fasten protection hole dimension Installation mode inserting type installation rear gear accessories fixed or guide rail installation 5 Main structural features 5.1 Accoun�ng switch on and switch off capacity by the fundamental wave reac�ve power may avoid any form and switch on and switch off vibra�on,and be able to demonstrate the eletrical network power factor correctly under the harmonic wave situa�on. 5.2 High,messuring accuracy of power factor,wide display scope. 5.3 Real �me display total power factor(pF)and fundanental wave power factor(DPF). 5.4 Real �me display voltage distor�on current distor�on rate. 5.5 There are 12 codes output types for user’s selec�on. 5.6 16 steps output max. 5.7 Friendly human-computer interface,easy to operate. 5.8 Digital parameter,easy to operate. 5.9 Auto running and manual running. 5.10 Over-voltage and under-voltage protec�ve fun�on. 5.11 Voltage harmonic wave over norm protec�ve func�on. 5.12 Memory data can not loss as it has breaking power supply protec�ve func�on. 5.13 Lower current signal input impedance ≤ 0.01Ω. 6 Ordering notes 6.1 Users should supply the number of circuits, rated voltage, and type of switch (contac

 Open the catalog to page 1

All Hengyi Electrical Co.,LTD catalogs and technical brochures

  1. HYSVG Sta

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.