HYSPC Three phase unbalance automatic adjusting device

HYSPC Three phase unbalance automatic adjusting device

HYSPC Three phase unbalance automatic adjusting device

Product catalog summary
Introduction and Schematic Diagram: The document discusses the common issue of three-phase unbalance in low voltage distribution systems, particularly in urban and agricultural networks. This unbalance can lead to increased line and transformer consumption, reduced transformer function, and potential safety risks. To address these issues, a three-phase unbalance automatic adjusting device has been designed to optimize power quality, save energy, and reduce emissions. The device can filter over 90% of zero sequence in rated capacity and control unbalance within 10%.
Specifications: The device operates within a voltage range of 400VAC±20% and a frequency of 50Hz with a deviation of ±5%. It offers zero sequence current compensation capacity of ≥90% and manages three-phase unbalance to ≤10%. The full-response time for compensation is less than 10ms, and it connects in parallel with a power consumption of less than 2.5% of capacity.
Normal Working and Installation Conditions: The device operates in temperatures from -10℃ to +40℃, with relative humidity between 5% and 95% without condensation. It is suitable for altitudes up to 1500m, with power reduced by 1% for every additional 100m up to 4000m. The environment should be free of harmful gases, steam, conductive or explosive dust, and violent mechanical vibrations. For outdoor installation, specific spacing requirements are outlined for maintenance access.
Model and Capacity: The device is available in different capacities (35kvar, 50kvar, 75kvar, 100kvar) and is designed for three-phase four-wire or three-phase three-wire systems with a voltage grade of 400V.
Technical Index: The document provides detailed technical specifications, including working voltage range, frequency, zero sequence current compensation, management capacity, response time, connection mode, and power consumption.
Installation and Order Tips: Installation diagrams and dimensions are provided for different capacities. Users are advised to provide site-specific features for customization. Optional modules for remote control via Wifi or GPRS are available.
See more

Catalog excerpts

HYSPC Three phase unbalance automatic adjusting device-1

HYSPC Three phase unbalance automatic adjusting device 1 Brief introducton and schematc diagram of the automate adjustment effect It is very common for three phase unbalance in the low voltage distributor In the urban network and agricultural network,due to a large number of single-phase load, and it is extremely serious for three phase current unbalance phenomenon. The current unbalance in the power grid will increase the consumpton of lines and transformer, lowering the functon of transformer, affectng the safe operaton of transformer, as well as zero drift, which may lead to three phase voltage unbalance, thus to lower the power supply quality. For the above mentoned conditon, in order to optmize the power quality, saving energy and reducing emission, we has specially designed three phase unbalance automatc adjustng device. This device can filter more than 90% of the zero sequence in the rated capacity, and control the three phase unbalance degree within 10%. Schematc diagram of the automatc adjustment effect of HYSPC three phase unbalance -►Load Current Transformer — quick response and instant management Imported 100A from phase B, respectvely transferred 50A to phase A and phase C, making output balance for phase A, phase B and phase C of the transformer, thus to avoid the power quality problems. a. Effectvely avoid partly heatng and aging for the middle lines, even the risk of fire. b. Effectvely equipment error alarming caused by partly voltage unbalance c. Effectvely avoid the risk of systemic weak electric equipment burnt caused by high zero ground voltage. d. Will not increase the actve power consumpton Outdoors 4:Three phase four wire 3:Three phase three wire Voltage grade: 400V Capacity: 35kvar, 50kvar, 75kvar, 100kvar Three phase unbalance adjustment Corporate code 3.2 Relatve humidity: : 5%~ 95% without condensaton. 3.3 Alttude: <1500m, between 1500 ~ 4000m, according to GB/T3859.2, the power will be lowered by 1% when adding 100m. 3.4 Environmental conditons: no harmful gas and steam, no conductve or explosive dust, no violent mechanical vibraton 3.5 Outdoor installaton: space of at least 15cm should be retained in the upper and lower outlet of the module, and space of at least60cm shall be reserved in the front and backof the cabinet to facilitate maintenance.

 Open the catalog to page 1
HYSPC Three phase unbalance automatic adjusting device-2

4.1 Working voltage range: three phase 400VAC ±20% . 4.2 Working frequency: 50Hz, allowed deviation of ±5%. 4.3 Zero sequence current compensation capacity:>90% (rated capacity) 4.4 Management capacity of three phase unbalance: <10% (rated capacity) 4.5 Full-response time for compensation: <10ms 4.6 Connection mode: Parallel connection 4.7 Power consumption: <2.5% of the capacity Capacity Size Weight Installation size Installation hole size (kavr) (mm) (kg) (mm) (mm) F rod Installation H rod Installation 7 Wifi module (mobile APP remote control) or GPRS module...

 Open the catalog to page 2