Group: DANAHER
Catalog excerpts
TECHNICAL DATA GENERAL Multifunctional counter tico 772/773/774 ■ Universally applicable as a tachometer, timer, shift counter, batch counter ... ■ Easy to operate ■ Four different backlight colours ■ Intensity of backlighting can now be adjusted ■ Large, clearly readable 48 x 48 mm display ■ Input frequency up to 60 kHz ■ Easy installation via plug-in terminals ■ Three presets Display LCD reflective, Transflective positive: black figures on backlit background Transmissive negative: white, red or green figures on backlit ground, 2 lines, 6-digit counter readings & presets; leading zero suppression, decimal point (up to 4 decimal places) Digit height 1st line 9.3 mm; 2nd line 7.2 mm Supply voltage SELV: 12-30 VDC; reverse polarity protected SELV: 24 VAC, 50/60 Hz ± 10% 115 VAC; 230 VAC, 50/60 Hz ± 10% 100-240 VAC 50/60 Hz ± 10% with switch-mode power supply Current consumption 12-30 VDC <200 mA, 12-30 VDC <250 mA with backlight 24 VAC <250 mA; including sensor supply 115/230 VAC <50 mA; including sensor supply 90 VAC max. 80 mA; including sensor supply with switch-mode power supply Power consumption <5 W <8 W with switch-mode power supply Duty cycle100% Overload protection External fuse DC: 0.16 AT (IEC 127); DC: 0.2 AT (UL 198) 24 VAC: 315 mAT; 230 VAC: 32 mAT; 115 VAC: 63 mAT Overload protection External fuse 230 V, 2.5 mAT Relay outputs DC: 0.16 AT (IEC 127); AC operation: 12-24 VDC (load dependent), max. 50 mA Switch-mode power supply: AC operation: 24 VDC/-5%, max. 115 mA max. capacitive load = 470 pF Data storage Non-volatile memory >10 years Electrical connection Plug-in screw-type connections/terminals Wire cross-section 1-1.5 mm2 with wire-end sleeves
Open the catalog to page 1Multifunctional counter tico 772/773/774 Amplitude threshold <2 V and >8 V or <1 V and >4 V at TTL level, Amplitude max. 40 VDC Active edge Programmable positive for PNP input, negative for NPN input Input resistance Approx. 10 kOhm Count frequency Max. 60 kHz; 30 Hz attenuated max. 20 kHz; 30 Hz attenuated in TTL operation Application input max. 6 kHz/30Hz attenuated To prevent the maximum input frequency of 60 kHz being exceeded, the following maximum input frequencies apply: Phase discriminator, single evaluation: A and B, each 30 kHz (20 kHz) TTL Phase discriminator, double...
Open the catalog to page 2COUNTER BATCH COUNTER SHIFT COUNTER TACHOMETER HENGSTLER Multifunctional counter tico 772/773/774 Counter mode Unidirectional; adding or subtracting; directional input; Input A,B Differential operation, add/sub; totalizing add/add; phase discriminator single, double or quadruple evaluation Control input Reset, gate Preselect modes Absolute or trailing, range signal/ limit values (signal 1 <P1, signal 2 >P 2) Application Output: prescaler out, preset 0 out, direction out input/output Input: additional counter input add/sub, reset, set, gate, keylock, Mode Batch counter...
Open the catalog to page 3ENVIRONMENTAL REGULATIONS, SAFETY PROVISIONS PHYSICAL DATA Data sheet tico 772/773/774 HENGSTLER Multifunctional counter tico 772/773/774 Accuracy Time base: ± 30 ppm of the timer Start/Stop-point in time: 16 ps/16 ms (not damped/damped) Overall tolerance = Displayed resolution + tolerance of timebase = 130 ppm Safety provisions EN 61 010-1/IEC 61010-1 Protection class II; EN 61010-1/IEC 61010-1 Pollution degree V 2, EN 50178 EMC interference EN 61326-1 industrial environment** compatibility EMC emissions EN 61326-1 Class B** Ambient temperature 0°-50°C EN 60 068-2-1/2 Storage...
Open the catalog to page 4COUNTING FREQUENCY AS A FUNCTION OF SIGNAL VOLTAGE The counting frequencies were determined using a signal generator with an output resistance of 50 ohms. DIMENSIONED DRAWINGS Data sheet tico 772/773/774
Open the catalog to page 5CONNECTION OPTIONS Input A Input B Input C Application input/outp. 7 OUT1_Tr, 12-24VDC/30mA AC.Supp|y 1 0“^ 8 OUT2_Tr, 12-24VDC/30mA extern- Fuse 9“‘ ‘ s A VAC Switch-mode power supply 2 relays/2 transistors_ USB - Ports Sicht auf die Geratebuchse View of the Plug 123x4 L [□□□□□! J Input A Input B Input C Application input/outp. OUTITr, 12-24VDC/30mA AC-Supply 8 OUT2_Tr, 12-24VDC/30mA extern. Fuse g s A max115mA 0V Input A Input B Input C Application input/outp. OUT1 Tr, 24VDC/50mA VAC Switch-mode power supply 1 relay/2 transistors_ Serial RS232 Port Sicht auf die Geratebuchse View of the...
Open the catalog to page 6Multifunctional counter tico 772/773/774 tico 772/773/774 ORDER INFORMATION Transflective positive: black figures on a white background Transmissive negative: white figures on a dark background Transmissive red: red figures on a dark background Transmissive green: green figures on a dark background Data sheet tico 772/773/774
Open the catalog to page 7All HENGSTLER catalogs and technical brochures
-
TYPE 636-DC
2 Pages
-
Types 864-868
2 Pages
-
X-56™ Thermal Printer
2 Pages
-
ACURO AD36
5 Pages
-
ACURO AR63
8 Pages
-
ACURO AR62
8 Pages
-
ACURO AC36
6 Pages
-
ACURO AC58
9 Pages
-
Colibri 490
2 Pages
-
Datasheet_AC58-CANopen_en
14 Pages
-
Datasheet_AC58-Interbus_en
14 Pages
-
Datasheet_AC58-Parallel_en
11 Pages
-
Datasheet_AC58-SSI-_en
11 Pages
-
Datasheet_AC58-EtherCAT_en
8 Pages
-
Light Duty types RI 32-O
3 Pages
-
Absolute Encoder AD 58
4 Pages
-
Counter complete catalog
304 Pages
Archived catalogs
-
relay RY en
5 Pages
-
relay product range safety
6 Pages
-
cutters catalog en
3 Pages
-
relay product range
6 Pages
-
printer catalog 2006
20 Pages
-
Complete thermoprinter catalog
20 Pages
-
Encoder Main Catalog
296 Pages