TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P ■ Compact design: 59 mm mounting depth for single or multiturn ■ Aids for start up and operation: diagnostic LED, preset key with optical response ■ Parameterization: Resolution, code type, direction, output format, warning, alarm ■ Parameters can be stored in a non-volatile memory ■ Integrated RS232 interface TECHNICAL DATA electrical Supply voltage Data sheet created © Hengstler GmbH, Uhlandstr. 49, D-78554 Aldingen/ Germany E-mail: info@hengstler.com Internet: www.hengstler.com

Open the catalog to page 1
Datasheet_AC58-SSI-_en - 2

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P RECOMMENDED DATA TRANSFER RATE bei SSI A clock brush is applied at the SSI interface, causing the encoder data to be serially clocked out. With each new clock brush (min. interval 30 ms) new data is readout. The following main parameters are programmable: • Preset: Software-Preset and via input/ pushbutton settable presets (can be inactivated) • Offset: Relative shifting of actual encoder value. • Scaling: The actual value of the encoder is multiplied with the factor < 1(direct entry, increments per measuring distance or per revolution). •...

Open the catalog to page 2
Datasheet_AC58-SSI-_en - 3

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P OUTPUT FORMAT SSI, MSB oriented, Multiturn OUTPUT FORMATS SSI, MSB oriented, Multiturn (not scaleable) Data sheet created 2009-12-15 12:07:08

Open the catalog to page 3
Datasheet_AC58-SSI-_en - 4

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P Data multiturn (number of revolutions) Data singleturn (Resolution per revolution)ELECTRICAL CONNECTIONS M23 connector (Conin), 12 pole / cable Cable Colour Data sheet created © Hengstler GmbH, Uhlandstr. 49, D-78554 Aldingen/ Germany E-mail: info@hengstler.com Internet: www.hengstler.com

Open the catalog to page 4
Datasheet_AC58-SSI-_en - 5

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P DIMENSIONED DRAWINGS Synchro flange "S" Connection M23 (Conin) Connection cable Interface: BiSS, SSI, ST-Parallel Interface: MT-Parallel (only with cable), Fieldbus, SSI-P axial radial Value in brackets alternative at SSI Data sheet created 2009-12-15 12:07:08 Cable bending radius R for flexible installation ≥ 15 x cable diameter Cable bending radius R for fixed installation ≥ 7.5 x cable diameter Cable Ø d BiSS/SSI/SSI-P: 7,1 +1,2 Cable Ø d ST-P: 7,8 +0,9 Cable Ø d MT-P: 9,3 +1,3 Cable Ø d Fieldbus: 7,1 +1,2 Dimensions in mm

Open the catalog to page 5
Datasheet_AC58-SSI-_en - 6

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P DIMENSIONED DRAWINGS (continued) Clamping flange "K" Connection M23 (Conin) Connection cable Interface: BiSS, SSI, ST-Parallel Interface: MT-Parallel (only with cable), Fieldbus, SSI-P axial radial alternative Data sheet created 2009-12-15 12:07:08 <8> Value in brackets alternative at SSI Cable bending radius R for flexible installation ≥ 15 x cable diameter Cable bending radius R for fixed installation ≥ 7.5 x cable diameter Cable Ø d BiSS/SSI/SSI-P: 7,1 +1,2 Cable Ø d ST-P: 7,8 +0,9 Cable Ø d MT-P: 9,3 +1,3 Cable Ø d Fieldbus: 7,1 +1,2...

Open the catalog to page 6
Datasheet_AC58-SSI-_en - 7

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P <1> Connection M23 (Conin) <2> Connection cable <3> Interface: BiSS, SSI, ST-Parallel <4> Interface: MT-Parallel (only with cable), Fieldbus, SSI-P <5> axial <6> radial <7> Value in brackets alternative at SSI <8> Customer side Cable bending radius R for flexible installation > 15 x cable diameter Cable bending radius R for fixed installation > 7.5 x cable diameter Cable 0 d BiSS/SSI/SSI-P: 7,1 +u Cable 0 d ST-P: 7,8 +0,9 Cable 0 d MT-P: 9,3 +1,3 Data sheet created © Hengstler GmbH, Uhlandstr. 49, D-78554 Aldingen/ Germany E-mail:...

Open the catalog to page 7
Datasheet_AC58-SSI-_en - 8

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P DIMENSIONED DRAWINGS (continued) Square flange "Q" Connection M23 (Conin) Connection cable Interface: BiSS, SSI, ST-Parallel Interface: MT-Parallel (only with cable), Fieldbus, SSI-P axial radial alternative Data sheet created 2009-12-15 12:07:08 <8> Value in brackets alternative at SSI Cable bending radius R for flexible installation ≥ 15 x cable diameter Cable bending radius R for fixed installation ≥ 7.5 x cable diameter Cable Ø d BiSS/SSI/SSI-P: 7,1 +1,2 Cable Ø d ST-P: 7,8 +0,9 Cable Ø d MT-P: 9,3 +1,3 Cable Ø d Fieldbus: 7,1 +1,2...

Open the catalog to page 8
Datasheet_AC58-SSI-_en - 9

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P ORDERING INFORMATION 1 Protection class IP67 not available in combination with preset key and LED display 2 IP67 on cover with connector only if IP67 mating connector mounted properly. Preferably available versions are printed in bold type. Data sheet created © Hengstler GmbH, Uhlandstr. 49, D-78554 Aldingen/ Germany E-mail: info@hengstler.com Internet: www.hengstler.com

Open the catalog to page 9
Datasheet_AC58-SSI-_en - 10

flexible COUPLINGS TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P Accessories Data sheet created © Hengstler GmbH, Uhlandstr. 49, D-78554 Aldingen/ Germany E-mail: info@hengstler.com Internet: www.hengstler.com

Open the catalog to page 10
Datasheet_AC58-SSI-_en - 11

TECHNICAL DATASHEET Absolute Encoder AC 58 - SSI-P Accessories CONNECTING CABLES (continued) CONNECTING CABLES Connecting cables with plug (socket) on one end Cable not made up with connectors TECHNICAL MANUALS Data sheet created 2009-12-15 12:07:08

Open the catalog to page 11

All HENGSTLER catalogs and technical brochures

  1. TYPE 636-DC

    2 Pages

  2. ACURO AD36

    5 Pages

  3. ACURO AR63

    8 Pages

  4. ACURO AR62

    8 Pages

  5. ACURO AC36

    6 Pages

  6. ACURO AC58

    9 Pages

  7. Colibri 490

    2 Pages

Archived catalogs

  1. relay RY en

    5 Pages