SURFACE WATER WASTEWATER L800 WATER ANALYZER THE MOST RELIABLE METHOD FOR / Advanced analytical method , High reliability & robustness / Low maintenance and long life-time / No interferences (Turbidity, Color, Salinity, Suspended solids,...) , Highly selective / Fast response time / Low detection limit / Low reagent consumption • CONFIGURABLE SETTINGS Adjusting various settings according to the user's requirements (measurement cycles, units, and views) • VARIOUS DISPLAY Graph mode, Overview, and Measurement cycle • EXPORTING DATA Save data or make screenshots on USB or SD card • REMOTE COMMUNICATION RS485 / Modbus RTU/TCP slave or master (Show value, calibration status, fault status...) *The parameter ranges are examples. Customized ranges on request. www.hemera.fr 25 avenue du Granier - 38240 Meylan - FRANCE
Open the catalog to page 1Controlling ammonium (NH4+) levels in water is crucial to protect the environment, human health, and wastewater treatment efficiency. High NH4+ can lead to eutrophication, toxic ammonia formation, and harm aquatic life. In drinking water, it contributes to nitrate contamination and chloramine formation, posing health risks. Wastewater plants must regulate NH4+ to optimize nitrification, prevent sludge issues, and comply with environmental regulations. Industries and agriculture also monitor ammonium to prevent corrosion, biofouling, and soil degradation. Effective control ensures clean water,...
Open the catalog to page 2Measurement principle UV FTLS SPECTROSCOPY IN GAS PHASE The gas phase measurement for NH4+ allows to avoid interferents such as turbidity, color, suspended solids or salinity, and to have a good accuracy of its concentration. BLANK TRANSMISSION SPECTRUM SAMPLE TRANSMISSION SPECTRUM MATHEMATICAL TREATMENT SAMPLE COLLECTION The sample is collected thanks to a tubing directly immersed in water or via a sampling system (not provided) if the analyzer cannot be positioned nearby. CONVERSION OF AMMONIUM (NH4+) INTO AMMONIA (NH3) The sample is injected into the sparger, and the addition of a reagent...
Open the catalog to page 3Touch screen Data transfer Operating temperature Operating humidity 8.5'' TFT colour screen 16/9 (LED backlight) COMMUNICATION OUTPUT 4-20 mA isolated (Active or Passive) / 500 Q max Programmable limit or fault alarms / 5A (NO) 3A (NC) @ 277 VAC RS485 / Modbus (Slave or Master) - Show value, calibration status, fault status... POWER SUPPLY Hemera Analyzers www.hemera.fr
Open the catalog to page 4z Online liquid & gas analyzers DO NOT HESITATE TO CONTACT US THROUGH OUR SALES REPRESENTATIVE Hemera Analyzers www.hemera.fr M