CE Laboratory Fume Hoods Full duty fume hoods in space and energy saving sizes of 30”, 36”, 48”, & 72” widths. UniFlow CE models are low ow constant volume fume hoods that require no VAV controls, no motorized bafes, no costly auxiliary air system and no special integral supply fans. These units can save 50% or more in costly exhaust volume typically required to operate a conventional fume hood. Fume hood is U.L.1805 classied. Access Panel removable to access ducting connections, plumbing & electrical services from a single point electrical box,115V/60Hz AC operation. Energy efcient T-5 two-bulb vapor proof uorescent light xture with polished stainless steel reectors, and light switch on left column, all factory installed. Full 27” Viewing Height for ease of access and unobstructed view of fume chamber while working with tall apparatus and distillation grids. Air Flow Monitor continuously monitors face velocity airow, analog or digital available. Meets ANSI and OSHA requirements. See page 37. Vertical Sash to be counterbalanced connected with coated stainless steel cables, 3/16” tempered safety glass with chemical resistant non-metallic PVC framing track and aerodynamic sash lift. VaraFlow Bafe System maintains uniform airow thru the VaraFlow bafe system to bell shaped exhaust collar outlet. Ergonomic Sash Lift contoured for efcient airow and ease of movement. 22” Sash Height for viewing of fume chamber, loading and unloading equipment for set up. Angled Picture Frame Opening The aerodynamic face opening with air foil provides uniform air ow into the fume chamber and thru the VaraFlow bafe system to the bell shaped exhaust collar. Sash Stop located at 1/2 open to reduce airow 50%, standard equipment. Cat. No. 51651 UniFlow CE Hood Cat. No. 14891, shown with optional accessories. SASH MANAGEMENT 1-2-3 1. Cut energy costs up to 50%. For improved lab efciency air ow monitors check the fume hood face velocity & help to insure that the proper amount of room air changes per hour are maintained. The sash stop is designed for user protection and cfm reduction, allowing the sash to open to a maximum position of half open. With an average utility rate of $7.00 per cfm a typical annual savings on a 4’ fume hood would be $2705.00 on a 6’ fume hood $4067.00. 2. Sash should only set to full open position for the set up of tall apparatus. Personal safety protection should be worn as recommended by the Lab Safety Ofcer. 3. When the fume hood is not in use return the sash to the closed position. HEMCO Corporation 711 S. Powell Road Independence, MO 64056 Fume Hood Face Velocity cfm The recommended face velocity for efciency & safety should be 80-100 fpm. Lower face velocity may compromise user safety. Sash in full open position should be for setup of apparatus & maintenance service only. If opening is at 1/2 open at 100 fpm (feet per minute), face velocity at full open would be approximately 50 fpm. UniFlow CE Fume Hood Sash Management & Design Size hood

Open the catalog to page 1
UniFlow CE Fume Hood - 2

CE Laboratory Fume Hoods UNIFLOW CE FUME HOOD DESCRIPTIONS Fume Hood Width A 36” Cat. No. 1. UniFlow CE Compact CAV Hood with Vapor Proof Light: The unitized superstructure Cat.No. features a molded seamless fume chamber with all corners coved. Manufactured of ame retardant chemical resistant composite resin using a minimum of metallic parts. Viewing sash is constructed of 3/16” clear tempered safety glass with frame and track fabricated of chemical resistant PVC. Equipped with varaow bafe system to efciently direct air through the fume chamber. Bafe is easily removed for cleaning. Vapor...

Open the catalog to page 2

All HEMCO Corporation catalogs and technical brochures

  1. Casework

    4 Pages

  2. Canopy Hoods

    2 Pages

  3. CMM Rooms

    1 Pages

  4. Modular Labs

    2 Pages

  5. Clean Rooms

    7 Pages