PAAR-TRONIC-CY - 1

Temperature range Peak operating voltage Test voltage core/core Test voltage core/screen Breakdown voltage Mutual capacitance core/core Capacitive coupling k1 Characteristic impedance Inductance Coupling resistance Minimum bending radius Mutual capacitance core/screen 07.07.2023 / We reserve the right to make technical changes; the imprint in the image is purely exemplary TECHNICAL DATA PVC data cable in alignment with DIN VDE 0812 flexible -5°C to +80°C fixed -30°C to +80°C 350 V (not for high power current installation purposes) 1200 V 800 V 2400 V at 800 Hz 0.14 - 0.25 mm2: approx. 100 pF/m 0.34 - 1.5 mm2: approx. 150 pF/m at 800 Hz 0.14 mm2: approx. 240 pF/m 0.25 mm2: approx. 270 pF/m at 800 Hz, max. 300 pF/100m 78 Ohm, (approx. value) approx. 0.65 mH/km at 30 MHz, approx. 250 Ohm/ km flexible 10x Outer-0 fixed 5x Outer-0 ■ CABLE STRUCTURE • Copper wire bare, 0.5 - 1.5 mm2: finely stranded acc. to DIN VDE 0295 Class 5 / IEC 60228 Class 5 • Wire structure: 0.14 mm2: approx. 18 x 0.1 mm 0.25 mm2: approx. 14 x 0.15 mm 0.34 mm2: 7 x 0.25 mm • Core insulation: PVC acc. to DIN VDE 0207-363-3 / DIN EN 50363-3 (compound type TI2) • Core identification acc. to DIN 47100 (paired stranding), colour coded Part no. No. cores x AWG, Outer Cu-weight Weight cross-sec. approx. 0 mm, kg/km kg/km, Continued on next page • x = without protective conductor • Cores stranded in pairs with optimal lay lengths, Pairs stranded in layers with optimal lay lengths • Foil wrapping • Drain wire, tinned copper • Screen: braided screen of tinned copper wires, approx. coverage 85% • Outer sheath: PVC acc. to DIN VDE 0207-363-4-1 / DIN EN 50363-4-1 (compound type TM2) • Sheath colour: grey (RAL 7032) • Length marking: in metres ■ PROPERTIES • largely resistant to: oil, for details, see "Technical Information" • the materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers ■ TESTS • flame-retardant acc. to DIN VDE 0482-332-1-2 / DIN EN 603321-2 / IEC 60332-1-2 • certifications and approvals: EAC ■ APPLICATION Suitable for flexible applications with free movement, without tensile stress and without forced motion control in dry, damp and wet rooms, however, not suitable for outdoor use. Used as control and signal cables for systems at risk of interference radiation. Due to the dense braided screening, interference through parallel running cables is suppressed and as a result of the pair stranding, favourable crosstalk attenuation values are achieved. EMC= Electromagnetic Compatibility; in order to optimise EMC properties, we recommend a double-sided and all-round large contact area of the copper braiding. ■ NOTES • the conductor is metrically (mm2) constructed, AWG numbers are approximated, and are for reference only Part no. No. cores x AWG, Outer Cu-weight Weight cross-sec. approx. 0 mm, kg/km kg/km,

Open the catalog to page 1
PAAR-TRONIC-CY - 2

07.07.2023 / We reserve the right to make technical changes; the imprint in the image is purely exemplary Part no. No. cores x AWG, Outer Cu-weight Weight cross-sec. approx. 0 mm, kg/km kg/km, Part no. No. cores x AWG, Outer Cu-weight cross-sec. approx. 0 mm, kg/km

Open the catalog to page 2

All HELUKABEL catalogs and technical brochures

  1. KMK-PA-MB

    2 Pages

  2. SiHF

    2 Pages

  3. H07RN8-F

    1 Pages

  4. IB

    1 Pages

  5. HTP

    1 Pages

  6. Cables & Wires

    1156 Pages

  7. Traycontrol

    4 Pages