Catalog excerpts
FERITSCOPE® FMP30 Measurement of the Ferrite Content in Austenitic and Duplex Steel Coating Thickness Material Analysis Microhardness Material Testing
Open the catalog to page 12 FERITSCOPE® FMP30 Measurement of the Ferrite Content Chemical, energy and processing plants are often subject to heat, aggressive media and high pressure. These circumstances demand steel with high corrosion and acid resistance that are resilient even at high temperatures. If the ferrite content is too low, then the welded material is susceptible to hot-cracking, if the ferrite content is too high, the toughness, ductility as well as the corrosion resistance of the steel are reduced. For duplex steel, a ferrite deficit in the area of the weld seam results in stress corrosion cracking and...
Open the catalog to page 23 Measurement influencing factors do not significantly affect the FERITSCOPE FMP30. Ferrite content measurements can be carried out regardless of the substrate material properties starting at a plating thickness of 3 mm. Corrective calibrations with customer-specific calibration standards or correction factors (included) can be used to take influences of the specimen shape (strong curvature), plating and substrate thicknesses into account. The calibration is always stored measurement-application specific in the respective application memory. Determination of the ferrite content in the weld...
Open the catalog to page 34 FERITSCOPE® FMP30 FERITSCOPE® FMP30 Measurement capture • Fast measurement and data storage • Automatic measurement acquisition upon probe placement or through “external trigger” • Enabled or disabled acoustic signal • Overwriting of erroneous measurements or previously stored readings • Selectable tolerance limits • Measurement data presentation as an analog bar with display of specification limits • Continuous display: Continuous display of the reading when probe is placed on the specimen; storing with externally triggered measurement acquisition • Outlier rejection function for the...
Open the catalog to page 45 Data memory • Up to 20,000 readings and 100 applications for measurement data and application-specific calibrations • Separation of the measurement data in up to 4,000 blocks • Date and time stamp for the blocks Evaluation • Statistical evaluation of measurement series with mean value, standard deviation, max and min value, range • Computation of the process capability indices cp and cpk • Output of characteristic variance-analytical values • Graphical measurement presentation as a histogram with a Gaussian bell curve Interfaces • USB port for data transfer to a PC or printer • Optional...
Open the catalog to page 56 FERITSCOPE® FMP30 Calibration and measurement method Magnetic induction method The FERITSCOPE FMP30 measures according to the magnetic induction method. A magnetic field generated by a coil begins to interact with the magnetic portions of the specimen. The changes in the magnetic field induce a voltage proportional to the ferrite content in a second coil. This voltage is then evaluated. All magnetic portions in the otherwise non-magnetic structure are measured, i. e., in addition to delta ferrite and other ferritic portions also strain-induced martensite, for example. A specific advantage...
Open the catalog to page 67 Probes with a measurement range 0.1 – 80 % Fe or 0.1 – 110 WRC-FN FGAB1.3-Fe For measurements on flat and curved areas 604-264 FGA06H-Fe For measurements on flat and curved surfaces. Very robust through a particularly wear-resistant probe tip 604-303 FGABI1.3-150-Fe FGABI1.3-260-Fe Ideal for measurements in pipes, bore holes or grooves Insertion diameter > 9 mm Shank length = 150 mm or 260 mm 604-254 604-341 FGABW1.3-Fe Angle probe for measurements on flat specimens or in pipes, bore holes and gaps 604-337 Calibration standard sets Corrective calibration standard set CAL-SS % Fe-WRC...
Open the catalog to page 7Fischer Instrumentation Electronique 78180 Montigny le Bretonneux, France Tel. +33 1 30 58 00 58 france@helmutfischer.com Helmut Fischer S.R.L. Tecnica di Misura, 20128 Milano, Italy Tel. +39 0 22 55 26 26 italy@helmutfischer.com Fischer Instruments, S.A. 08018 Barcelona, Spain Tel. +34 9 33 09 79 16 spain@helmutfischer.com Helmut Fischer Meettechniek B.V. 5627 GB Eindhoven, The Netherlands Tel. +31 40 248 22 55 netherlands@helmutfischer.com Fischer Instruments K.K. Saitama-ken 340-0012, Japan Tel. +81 4 89 29 34 55 japan@helmutfischer.com Fischer Instrumentation (Far East) Ltd Kwai Chung,...
Open the catalog to page 8All HELMUT FISCHER GMBH - INSTITUT FÜR ELEKTRONIK UND catalogs and technical brochures
-
MMS® Inspection
8 Pages
-
MMS® Inspection DFT
6 Pages
-
FISCHERSCOPE ® X-RAY SERIES
48 Pages
-
PRECIOUS METALS AND JEWELERY
4 Pages
-
Automated Measurement Solutions
28 Pages
-
FISCHERSCOPE® X-RAY XAN® 500
4 Pages
-
FISCHERSCOPE® ST200
4 Pages
-
MMS-PC2
16 Pages
-
SIGMASCOPE GOLD
4 Pages
-
XAN250-252
4 Pages
-
XAN220-222
4 Pages
-
Inline Measuring Systems
8 Pages
-
XAN Series
36 Pages
-
GOLDSCOPE Series
8 Pages
-
PMP10 Duplex
4 Pages
-
FMP100/150
8 Pages
-
MP0/MP0R Series
8 Pages
-
Brochure DUALSCOPE® FMP100
8 Pages
-
FISCHERSCOPE X-RAY XDV-SDD
2 Pages
-
FISCHERSCOPE X-RAY XDAL
2 Pages
-
PHASCOPE PMP10 DUPLEX
4 Pages
-
Probe catalogue
12 Pages
-
FISCHERSCOPE MMS PC2
16 Pages
-
FISCHERSCOPE X-RAY
36 Pages
-
FISCHER Product Overview