Certified FISCHER X-RAY Calibration Standards and Accessories DIN ISO/IEC 17025 accredited March 2018/2 Q Coating Thickness [jjj] Material Analysis [5l Microhardness [§] Material Testing
Open the catalog to page 1Quality Assurance with Energy-dispersive X-Ray Fluorescence Analysis (EDXRF Analysis) Quality assurance and optimum processing procedures play an ever greater role in production. From this stems the necessity to perform reliable measurements, which also comply with the demanding requirements of an ISO certified quality management system. Energy-dispersive X-ray fluorescence analysis (EDXRF analysis) is a particularly universal, fast and nondestructive measuring method. By using suitable reference materials, it enables coating thicknesses and material composition for a large number of...
Open the catalog to page 2Traceability of Calibration Standards The traceability of FISCHER calibration standards is effected on the basis of the following procedures: The DAkkS Calibration Certificate . . . . . . . . . . . . . 4 In accordance with a procedure that is accredited by the German Accreditation Service, Deutscher Akkreditierungsservice (DKD/DAkkS), see the accreditation certificate. This procedure can be applied for many pure-element coatings. The FISCHER Calibration Laboratory ensures traceability to internationally recognized material measures. You will find the accreditation document on the FISCHER...
Open the catalog to page 3The DAkkS Calibration Certificate The Front Page of the DAkkS Calibration Certificate The insignia designates the DAkkS calibration certificate as an official document. Strict requirements apply to calibration laboratories, and these requirements are regularly checked by the accreditation body of the German Calibration Service, Deutscher Kalibrierdienst (DKD). akkreditiert durch die / accredited by the Deutsche Akkreditierungsstelle GmbH als Kalibrierlaboratorium im / as calibration laboratory in the Calibration certificate Calibration mark Gegenstand Object Hersteller Manufacturer...
Open the catalog to page 4The Back Page of the DAkkS Calibration Certificate Description of the calibration object The traceability of the calibration standards is effected via a comparison measurement by means of Xray fluorescence analysis against gravimetrically measured reference standards. Identification of the calibration standard (as it is also printed on the standard), material and the mass per unit area that is determined. The mass per unit area is the size, which an X-ray fluorescence instrument determines. The coating thickness is derived from the mass per unit area via the material density. In the case of...
Open the catalog to page 5Customer-specific Calibration Standards FISCHER offers you the unique service of being able to certify your own product as a calibration standard. In many cases it is even possible to issue an internationally recognized DAkkS calibration certificate. You can show this to your customers and populate it to an existing quality management system in accordance with ISO 9000/1. You also gain security with this in your production process, if a calibration standard corresponds to your products. The production of traceable calibration standards is very time-consuming and also dependent on the...
Open the catalog to page 6DAkkS Column All calibration standards will be delivered with a manufacturer‘s certificate. If the table starting on Page 8 displays a green check mark , then you do have the option to order a DAkkS calibration certificate for this standard. If the table row doesn‘t show , then the standard is available with manufacturer‘s certificate only. Differences between Standards with a Manufacturer‘s Certificate and DAkkS Certified Standards Produced by a DAkkS certified calibration laboratory Standard with manufacturer‘s certificate DAkkS certified standard Produced in accordance with DAkkS...
Open the catalog to page 7X-RAY Calibration Standards Catalog Solid Standards Coatings KAL-N 1: Solid Standards Single Coatings Coating structure Base material
Open the catalog to page 8Solid Standards
Open the catalog to page 9Part No. Designation DAkkS 604-635 KAL-N dd Ag/Ni/Alloy42 1.0/1.0 |jm 604-636 KAL-N dd Ag/Ni/Alloy42 1.0/3.0 jm 604-637 KAL-N dd Ag/Ni/Alloy42 5.0/1.0 jm 604-638 KAL-N dd Ag/Ni/Alloy42 5.0/3.0 jm 604-619 KAL-N dd Ag/Ni/Cu 1.0/1.0 jm 604-620 KAL-N dd Ag/Ni/Cu 1.0/3.0 jm 604-116 KAL-N dd Ag/Ni/Cu 1.0/15 jm 604-621 KAL-N dd Ag/Ni/Cu 5.0/1.0 jm 604-622 KAL-N dd Ag/Ni/Cu 5.0/3.0 jm 604-651 KAL-N dd Ag/Ni/CuZn30 1.0/1.0 jm 604-652 KAL-N dd Ag/Ni/CuZn30 1.0/3.0 jm 604-653 KAL-N dd Ag/Ni/CuZn30 5.0/1.0 jm 604-654 KAL-N dd Ag/Ni/CuZn30 5.0/3.0 jm 604-629 KAL-N dd Au/Ni/Alloy42 0.25/1.0 jm Part...
Open the catalog to page 10Part No. Designation DAkkS 601-895 KAL-N dd Au/Ni/Cu 0.8/2.5 jm 604-615 KAL-N dd Au/Ni/Cu 1.0/1.0 jm 604-616 KAL-N dd Au/Ni/Cu 1.0/3.0 jm 602-087 KAL-N dd Au/Ni/Cu 1.5/10 jm 604-617 KAL-N dd Au/Ni/Cu 2.5/1.0 jm 604-618 KAL-N dd Au/Ni/Cu 2.5/3.0 jm 602-086 KAL-N dd Au/Ni/Cu 2.5/5.0 jm 604-645 KAL-N dd Au/Ni/CuZn30 0.25/1.0 jm 604-646 KAL-N dd Au/Ni/CuZn30 0.25/3.0 jm 604-647 KAL-N dd Au/Ni/CuZn30 1.0/1.0 jm 604-648 KAL-N dd Au/Ni/CuZn30 1.0/3.0 jm 604-649 KAL-N dd Au/Ni/CuZn30 2.5/1.0 jm 604-650 KAL-N dd Au/Ni/CuZn30 2.5/3.0 jm 602-996 KAL-N dd Au/Pd/Ni 0.5/0.8 jm Part No. Designation...
Open the catalog to page 112.5 pm 602-070 KAL-N dc Sn60Pb40/Ni 11 pm 602-071 KAL-N dc Sn60Pb40/Ni 40 pm 602-072 KAL-N dc Sn90Pb10/Ni 2.0 pm 602-073 KAL-N dc Sn90Pb10/Ni 10.5 pm 12 X-RAY Calibration Standards
Open the catalog to page 12KAL-N: Solid Standards Pure Elements Part No. Designation DAkkS Bulk KAL-N: Solid Standards Ultra-High Purity Elements1 Delivery with certificate of analysis
Open the catalog to page 13Solid Standards Bulk Part No. Designation DAkkS Part No. Designation DAkkS Continued on the next page The standard measurement uncertainty is determined for each calibration standard individually. For gold and silver standards the standard measurement uncertainty of the calibration standards is always below 0.25 %. 14 X-RAY Calibration Standards
Open the catalog to page 14KAL-N: Solid Standards Alloys (Bulk) - Continuation Part No. Designation DAkkS 601-849 KAL-N c Kovar2 604-036 KAL-N c Pt950Cu50 604-037 KAL-N c Pt960Ru40 603-896 KAL-N c RoHS PE Low: Br 500 ppm, Hg 200 ppm, Cr 398 ppm, Pb 400 ppm, Cd 100 ppm 603-895 KAL-N c RoHS PE High: Br 1099 ppm, Hg 1100 ppm, Cr 1000 ppm, Pb 1201 ppm, Cd 300 ppm 603-988 KAL-N c RoHS PVC Blank 603-987 KAL-N c RoHS PVC-Low: Br 499 ppm, Hg 200 ppm, Cr 400 ppm, Pb 399 ppm, Cd 100 ppm 603-989 KAL-N c RoHS PVC High: Br 1099 ppm, Hg 1100 ppm, Cr 1000 ppm, Pb 1199 ppm, Cd 301 ppm 604-268 KAL-N c Sn62Pb36Ag2 The standard...
Open the catalog to page 15All HELMUT FISCHER GMBH - INSTITUT FÜR ELEKTRONIK UND catalogs and technical brochures
-
MMS® Inspection
8 Pages
-
MMS® Inspection DFT
6 Pages
-
FISCHERSCOPE ® X-RAY SERIES
48 Pages
-
PRECIOUS METALS AND JEWELERY
4 Pages
-
Automated Measurement Solutions
28 Pages
-
FISCHERSCOPE® X-RAY XAN® 500
4 Pages
-
FISCHERSCOPE® ST200
4 Pages
-
MMS-PC2
16 Pages
-
SIGMASCOPE GOLD
4 Pages
-
XAN250-252
4 Pages
-
XAN220-222
4 Pages
-
Inline Measuring Systems
8 Pages
-
XAN Series
36 Pages
-
GOLDSCOPE Series
8 Pages
-
PMP10 Duplex
4 Pages
-
FMP100/150
8 Pages
-
MP0/MP0R Series
8 Pages
-
Brochure DUALSCOPE® FMP100
8 Pages
-
FISCHERSCOPE X-RAY XDV-SDD
2 Pages
-
FISCHERSCOPE X-RAY XDAL
2 Pages
-
PHASCOPE PMP10 DUPLEX
4 Pages
-
Probe catalogue
12 Pages
-
FISCHERSCOPE MMS PC2
16 Pages
-
FISCHERSCOPE X-RAY
36 Pages
-
FISCHER Product Overview
24 Pages