Product catalog summary
Introduction
Hellma Analytics is a prominent provider of high-precision optical solutions, specializing in certified reference materials for UV/Vis spectroscopy. Accredited to DIN EN ISO 17025, the company ensures high-quality measurements and international comparability, with products used globally to meet regulatory standards and ensure product safety.
Certified Test Equipment
Hellma Analytics offers certified reference materials for spectrophotometers, essential for ensuring photometric and wavelength accuracy. These materials are traceable to NIST and PTB standards, complying with ISO 9001, GLP, GMP, and Pharmacopeias.
Glass and Liquid Filters
Glass filters, robust certified reference materials, are used for checking wavelength and photometric accuracy, traceable to NIST standards. Liquid filters, filled into quartz glass cuvettes, check wavelength accuracy, photometric accuracy, stray light levels, and spectral resolution, simulating real measuring conditions.
DAkkS Calibration Certificate
Reference materials are certified in Hellma's calibration laboratory, accredited to DIN EN ISO 17025, with a DAkkS calibration certificate ensuring reliable measurement values for spectrophotometer calibration.
Warranty and Recertification
Hellma Analytics provides a 30-year warranty on reference materials, contingent on regular recertification every two years, involving cleaning and re-certifying to ensure continued accuracy and reliability.
Usage Guidelines
Detailed procedures for using glass and liquid filters to check spectrophotometer accuracy are provided, including steps for checking wavelength and photometric accuracy, stray light levels, and spectral resolution.
Glass Filters Overview
Glass filters, made from glass doped with metal ions or rare earth metals, are used for testing wavelength and photometric accuracy. Types include Holmium, Didymium, and Neutral Density Glass Filters, each with specific applications and certifications.
Calibration and Measurement Procedures
Calibration involves warming up the spectrophotometer, ensuring stable cuvette holders, and performing baseline corrections. Specific filters are used for wavelength and photometric accuracy, with measurement parameters aligning with the calibration certificate.
Measurement Uncertainty
Measurement uncertainties are specific to conditions, including the spectrophotometer used and environmental factors. Users should combine these uncertainties with their own for precise results.
Liquid Filters
Liquid filters like Holmium, Didymium, and Rare Earth are used for checking wavelength accuracy, while Potassium Dichromate and Niacin filters check photometric accuracy. Stray light is checked using cut-off filters.
Conclusion
The document provides comprehensive procedures for calibrating spectrophotometers using various filters, emphasizing the importance of understanding measurement uncertainties and specific conditions.
Recertification
Recertification is crucial for maintaining accuracy, with recommended intervals of 12 months for liquid filters and 24 months for glass filters after the first two years.
FAQs
Includes information on recertification processes, filter maintenance, calibration standard lifespan, and measurement uncertainty calculations.
Glossary
Defines key terms such as absorbance, transmittance, and spectral resolution, essential for understanding absorption spectrometry principles.
See more

Catalog excerpts

Reference Materials (Brochure)-1

Certified Reference Materials for UV/ Vis Spectroscopy PRODUCT CATALOG WITH USAGE GUIDELINES GLASS FILTERS LIQUID FILTERS REFERENCE PLATES TRACEABLE

 Open the catalog to page 1
Reference Materials (Brochure)-2

YOUR PROCESS. OUR SOLUTIONS. As a leading supplier of high-precision, optical solutions that are 'Made in Germany' from glass, quartz glass and synthetic crystals, Hellma has been a by-word for outstanding quality for over 95 years. A key supplier, the company is an integral part of its clients’ value chains. Reliability, trust and continuity are inherent in Hellma’s work, and the company believes it has both a duty and responsibility to ensure these principles are upheld. Clients from more than 40 countries worldwide put their confidence in Hellma’s exceptional level of performance and problem-solving...

 Open the catalog to page 2
Reference Materials (Brochure)-3

1.1 Hellma Analytics calibration laboratory Page 7 2.1 Checking wavelength accuracy 2.1.1 Holmium glass filter 2.1.2 Didymium glass filter 2.2 Checking the photometric accuracy 2.2.1 Didymium glass filter F7A 2.2.2 Neutral density glass filter 2.3 Glass filter sets 2.4 General usage guidelines for glass filters 2.5 Calibration with glass filters 2.5.2 Steps for checking wavelength accuracy with holmium glass or didymium glass filter 2.5.3 Steps for checking photometric accuracy with a Neutral density glass filter or a didymium glass filter (F7A) 2.5.4 Calibration...

 Open the catalog to page 3
Reference Materials (Brochure)-4

1.1  Hellma Analytics calibration laboratory: accredited to DIN EN ISO 17025 Our lab is a DAkkS calibration laboratory and is accredited to DIN EN ISO 17025, a comprehensive quality management system that acts as a seamless continuation of other systems such as ISO 9001. By achieving this accreditation, we have demonstrated proof of expertise in the calibration activities that we perform and are authorized to issue internationally recognized DAkkS calibration certificates. The accreditation is the key to high quality measurements, international comparability, and trust in both the work of the...

 Open the catalog to page 4
Reference Materials (Brochure)-5

1. INTRODUCTION 1.2 Certified test equipment Quality assurance and quality control regulations, such as ISO 9001, GLP, GMP, and Pharmacopeias, require companies to verify the consistently excellent performance of any spectrophotometer in use. The two most important factors for obtaining precise spectrophotometer data are the photometric accuracy (absorbance accuracy) and wavelength accuracy of the spectrophotometer, which should be tested on a regular basis. In the Hellma Analytics calibration laboratory, which is accredited to DIN EN ISO 17025, we manufacture certified reference materials based...

 Open the catalog to page 5
Reference Materials (Brochure)-6

1.5 DAkkS calibration certificate After careful production, reference materials are certified in the Hellma Analytics calibration laboratory (accredited to DIN EN ISO 17025) using a high-performance UV-Vis/NIR spectrophotometer. Reference materials are only consid ered to be certified if they have been issued with a DAkkS calibration certificate and bear a calibration mark. Using the measurement values documented and certified in the calibration certificate, users can check and calibrate their spectrophotometers accordingly. IMPORTANT INFORMATION Only if the DAkkS calibration certificate has...

 Open the catalog to page 6
Reference Materials (Brochure)-7

1. INTRODUCTION 1.5 DAkkS calibration certificate lD 1.6 Warranty 30-year manufacturer's warranty on all Hellma Analytics reference materials Measurement value and smallest attributed measurement uncertainty that can be specified. This value only refers to Hellma Analytics measurements and applies solely to the company's specific measurement conditions. In justified cases, calibration certificates may also show measurement results that do not fall within the calibration laboratory's scope of accreditation. These must be clearly labeled as such on the calibration certificate. Notes on initial...

 Open the catalog to page 7
Reference Materials (Brochure)-8

GLASS FILTERS 2. GLASS FILTERSWAVELENGTH ACCURACY 2.1 Checking wavelength accuracy APPLICATION To measure wavelength accuracy, the filter absorbs the light beam of the spectrophotometer to a greater extent at certain wavelengths creating absorbance peaks. Ideally, any reference materials used to determine wavelength accuracy should have narrow, well-defined peaks at a variety of wavelengths in the UV and visible range. 2.1.1 Holmium glass filter PRODUCT DESCRIPTION The holmium glass filter 666-F1 has a range of narrow, well-defined peaks in the UV and visible range, making holmium an excellent...

 Open the catalog to page 8
Reference Materials (Brochure)-9

GLASS FILTERS 2. LASS FILTERS G PHOTOMETRIC ACCURACY 2.2  Checking the photometric accuracy APPLICATION To measure photometric accuracy (absorbance), the filter reduces the light beam from the spectrophotometer. An absorbance value (Abs) can be deduced from the light extinction caused by the filter. Absorbance behavior in the UV range can be checked at 270 nm, 280 nm, 297 nm, 321 nm, and 342 nm. Filters are routinely set at a thickness that produces a nominal optical density of 0.5 Abs at 342 nm. This results in increasingly larger absorbances the shorter the wavelengths become. 2.2.1  Didymium...

 Open the catalog to page 9
Reference Materials (Brochure)-10

2. LASS FILTERS G SETS 2.3  Glass filter sets 2.4  General usage guidelines for glass filters Specifically created to meet customer requirements, Hellma Analytics glass filter sets consist of existing individual filters suitable for standard or custom validation procedures. Glass filters are made of glass doped with metal ions/rare earth metals, which are assembled stress-free in black anodized precision frames made of aluminum. They are designed to fit into all spectrophotometers equipped with a holder for standard cuvettes with a 10-mm optical path length. To ensure that filters can be easily...

 Open the catalog to page 10
Reference Materials (Brochure)-11

2.5  Calibration with glass filters 2.5.1  Preparations 2.5.2  Steps for checking wavelength accuracy with holmium glass or didymium glass filter 1 First, carry out the "Preparations" according to chap. 2.5.1 Warm up the spectrophotometer until the correct operating temperature has been reached and remains constant (e.g. for one hour), taking care to observe the device manufacturer’s guidelines. Run the scan program on your spectrophotometer, observing the guidelines in the user manual. Select a scanning range that covers all of the peaks listed on the filter’s calibration certificate. Make sure...

 Open the catalog to page 11

All Hellma GmbH & Co. KG catalogs and technical brochures

  1. TrayCell 2.0

    4  Pages

  2. Raman probes

    2  Pages

  3. Competence

    21  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.