video corpo

1809 MARKIII

1809 MARKIII

1809 MARKIII

Product catalog summary
Heller Reflow Oven Specifications Overview
Model Variants: 1809 MARKIII (Air) and 1809 MARKIII (Nitrogen)
Electric Supply: Both models require a standard power input of 480 volts, with a breaker size of 100 amps. They operate at 8.5 - 10.5 kW continuously and have a typical run current of 20 - 25 amps. Optional power inputs range from 208 to 440 VAC, with a frequency of 50/60 Hz.
Dimensions and Weight: The ovens measure 183" in length, 54" in width, and 63" in height. The net weight is approximately 3500 lbs, with shipping weights varying between 4000 lbs (domestic) and 4500 lbs (export).
Computer Control: Equipped with AMD or Intel-based computers, these ovens support recipe storage of over 500 entries, feature a flat screen monitor, and run on Windows XP®. Additional features include auto start software, data logging, password protection, and optional LAN networking.
Inert Atmosphere (Nitrogen Model): Features include a minimum oxygen level of 10-25 PPM, nitrogen cooling, and optional systems for waterless cooling, nitrogen on/off valve, oxygen monitoring, and standby systems.
Additional Features: Both models come with KIC/ECD profiling software, signal light tower, powered hood lift, and five thermocouple profiling. Optional features include redundant alarm sensors, independent alarm scanner, board support systems, and custom engineering.
Mesh Belt Conveyor: The conveyor height is adjustable, with a maximum PCB width of 24" for the nitrogen model. The heated tunnel length is 105", and the maximum conveyor speed is 74"/min.
Temperature Control: The ovens offer a temperature range of 25-350°C, with optional high temperatures up to 450°C. The accuracy of the temperature controller is +0.1°C, with a cross-belt temperature tolerance of +3.0°C.
Cooling Systems: Standard models have two cooling zones, with an option for a third. Water and waterless cooling options are available for the nitrogen model.
Notes: Specifications are subject to change as part of continuous product improvement. Contact information for various global offices is provided for further inquiries.
See more

Catalog excerpts

1809 MARKIII-1

HELLER INDUSTRIES, INC. Model Electric Supply Power Input (3 Phase) Standard Breaker Size kW Typical Run Current Optional Power Inputs Available Frequency Sequential Zone Turn On Single Phase Operation Dimensions Overall Length Overall Width Overall Height Typical Net Weight Typical Shipping Weight (Domestic) Typical Shipping Weight (Export) Computer Control AMD or Intel Based Computer Recipe Storage Flat Screen Monitor Windows Operating System Monitor mount Auto Start Software Data Logging Password Protection LAN Networking Inert Atmosphere Minimum PPM Oxygen Nitrogen Cooling Waterless Cooling w/ Flux Separation System Nitrogen On/Off Valve Oxygen Monitoring System Nitrogen Standby System Sample Port in Reflow Typical Nitrogen Consumption Additional Features KIC / ECD Profiling Software Signal Light Tower Powered Hood Lift Five (5)Thermocouple Profiling 30” Heater Modules Redundant Alarm Sensors Independent Alarm Scanner KIC Profiler / ECD Profiler Center Board Support Board Drop Sensor Board Counter Bar Code Reader Custom Paint & Decal Battery Backup for Conveyor and PC GEM/SECS Interfacing Custom Engineering and Software Heller Reflow Oven Specifications 1809 MARKIII (Air) * Varies depending on Options included with the oven ** Tested at 500 PPM. Varies with PCB size and oven configuration Specifications Continue on Reverse

 Open the catalog to page 1
1809 MARKIII-2

HELLER INDUSTRIES, INC. Model Mesh Belt Conveyor Height From Floor Maximum PCB Width *** Requires 30” Heater Modules Space Required Between PCB's Conveyor Length On-Load Conveyor Length Off-Load Heated Tunnel Length Process Clearance Above Mesh Belt Mesh Belt Pitch Maximum Conveyor Speed Conveyor Direction Left to Right Conveyor Direction Right to Left Conveyor Speed Control Type Edge Hold Conveyor System Option Height from Floor – Standard Height from Floor – Optional Clearance Above Conveyor Pins Clearance Below Conveyor Pins Length of PCB Support Pins 3 mm long support pins Minimum/Maximum...