264 Preventive fire protection in multi storey buildings The aim of fire protection in ducting is to prevent the spread of fire from room to room and floor to floor in a building. Building design specifies compartments in the building protected by fire rated walls, floors and ceilings. However, it is necessary to make openings in these walls, ceilings and floors for services. Helios offer a range of options with certified fire ratings to maintain the integrity of the fire wall etc. Fire damper ELS-D Fire protection element for ventilation ductings according to DIN 18017. For vertical installation in ducting directly below the ceiling. With installation of the ELS-D, the use of further classified fire protection elements on air intakes or extracts is unnecessary. Ideal for use in installation shafts with mixed mains (also with combustible mains). Approved for single and central ventilation systems as well as for intake and extract systems. Maintenance free. Details see page 270 New fire protection system BSH for ventilation systems K 90-DIN 18017. Cost effective and maintenance free. Prevents the transmission of fire and smoke. Installation in ceiling sector through insertion in the vertical main ducting (spiral ducting). T-pieces are unnecessary because of model range (with 0, 1 or 2 side spigots). Ideal for use in installation shafts with mixed mains (also with combustible mains) in combination with single ventilation units (ELS). Details see page 58 Fire protection systems and shutter elements from Helios
Open the catalog to page 1265 Fire rated protection shutter BA.. K 90-DIN 18017 and K 30 DIN 4102 Prevents the transmission of fire and smoke through ventilation ducting or ventilation openings in other fire sectors. For insertion in spiral ducting and with mounting sleeve for installation in fire resistant walls. Pages 266-267 Fire protection valve BTV K 90-DIN 18017 and valve with fire release cone BTK K 90-DIN 4102 Shutter element with air flow throttle to prevent fire and smoke transmission through ventilation ductings or ventilation openings. Suitable for insertion in spiral ducting and with mounting sleeve for installation...
Open the catalog to page 2266 Fire protection shutter K 90-DIN 18017 BAE Installation examples In-line installation The element is to be installed through simple insertion (e.g. in spiral ducting) and to be fixed together with the duct in the wall. Suitable for installation in both directions, independent from air flow direction. Wall installation With mounting sleeve (accessory) in walls of brick, thermolite block or plaster panel, shaft partition walls in F 90, F 60 and F 30... or system proofed walls with more than 40 mm thickness. Suitable for installation in both directions, independent from air flow direction. Fire...
Open the catalog to page 3267 Fire protection shutter K 30-DIN 4102 BAK Installation examples In-line installation The element is to be fixed through insertion in mounting sleeve (accessory) and to be mounted together in the shaft wall. Installation is independent from air flow direction. Following connection to ducting on both ends of the mounting sleeve. Wall installation With mounting sleeve (accessory) in walls of brick, thermolite block or plaster panel, shaft partition walls or system proofed walls with more than 40 mm thickness. Suitable for installation in both directions, independent from air flow direction....
Open the catalog to page 4268 Fire protection valve K 90-DIN 18017 BTV Fire rating 90 minutes K 90-DIN 18017 Fire protection valve with fusible link release Operation Quick release value care to prevent fire and smoke transmission. Suitable for installation in ventilation shafts and ducting with required fire resistance class K 90-DIN 18017. Suitable for insertion in spiral ducting or for wall installation with mounting ring (included as standard). Function When the surrounding temperature of +72 °C is exeeded, the integrated fusible link releases. The built-in pressure spring closes the valve core automatically. Certified...
Open the catalog to page 5269 Fire protection valve K 90-DIN 4102 BTK Fire rating 90 minutes K 90-DIN 4102 Fire protection valve with fusible link release Operation Shutter to prevent fire and smoke transmission. Suitable for installation in ventilation shafts or walls that act as fire sector with required fire resistance class K 90-DIN 4102. Suitable for insertion in spiral ducting or for wall installation with mounting sleeve EH (included as standard). Function When the surrounding temperature of +72 °C is exeeded, the integrated fusible link releases. The built-in pressure spring closes the valve core automatically....
Open the catalog to page 6270 Fire damper ELS-D For single and central ventilation systems K 90-DIN 18017 F mm 250 250 250 250 250 250 H mm 85 94 103 113 124 134 ELS-D 100 125 140 160 180 200 A mm 183 208 233 258 283 308 Ref. No. 0270 0185 0186 0187 0188 0271 C mm 385 394 403 413 424 434 ø d mm external 99 124 139 159 179 199 B mm 123 148 163 183 203 223 E mm 50 50 50 50 50 50 Weight in kg 2.5 3.4 4.0 5.0 6.0 7.2 ø D mm internal 102 127 142 162 182 202 Dimesions and model range Fire rating 90 minutes K 90-DIN 18017 According to building regulations ventilation ducts that cross more than two storeys vertically must be...