video corpo

TWL-Exd

TWL-Exd
1 / 14 PagesView full catalog

TWL-Exd

Product catalog summary
Overview: The document outlines the specifications and applications of KOBOLD's Resistance Thermometers Model TWL Exd, which are designed for temperature measurement in various media such as liquids, solids, and gases. These thermometers are suitable for hazardous areas with ignition protection Exd.
Specifications:
  • Measuring Range: -198 to +600 °C.
  • Sensors: Pt100 sensors available in classes F0.3, F0.15, F0.1, F0.03, and cryogenic.
  • Output: Resistance or analogue 4-20 mA.
  • Thermowells: Available in lengths up to 5000 mm.
  • Options: Head transmitter with HART® protocol or PROFIBUS®/Fieldbus, display options.
  • Materials: Stainless steel for sensor, thermowell, and neckpipe; aluminum for connection head.
Applications: Suitable for use in air-conditioning, cooling, heating, furnace, mechanical, and apparatus construction industries, and can operate under gauge pressure and vacuum conditions.
Technical Details:
  • Measurement Principle: Temperature-dependent resistor.
  • Accuracy: Various classes available, including cryogenic.
  • Ambient Temperature: Ranges from -40 to +150 °C depending on configuration.
  • Operating Pressure: Up to 250 bar, depending on thermowell.
  • Connection Head: Form XD with chain, IP protection varies.
Head Transmitter: Provides a temperature-linear output signal of 4-20 mA, available with HART® or PROFIBUS®/Fieldbus® communication systems.
ATEX Approval: Certified for use in hazardous areas with II 2 GD Ex d IIC T6 rating.
Ordering Details: Includes model, sensor specification, wiring, connection head, process connection, and thermowell specifications. Custom options are available upon request.
Diagrams and Dimensions: Detailed illustrations and dimensions for various models and configurations, including thermowell types and connection options.
Thermowell Specifications:
  • Models: Includes tapered shank and cylindrical types with process connections such as G-thread, NPT-thread, flange, and weld-on. Maximum pressure rating is PN 250 at 20°C for most models.
  • Process Connections: Specified connection types include G-thread, NPT-thread, and flange connections according to standards like EN-1092, ASME, and ANSI B16.5.
  • Dimensions: Provided for each thermowell model, including maximum total length, diameter, and other critical measurements.
Procedures and Recommendations:
  • Ensure compatibility of thermowell dimensions with process requirements.
  • Verify pressure ratings and connection types before installation.
Norms and Standards:
  • Flange connections adhere to EN-1092 and ASME standards.
  • ANSI B16.5 standards are referenced for certain flange connections.
Important Notes:
  • No responsibility is taken for errors; specifications are subject to change without prior notice.
See more

Catalog excerpts

TWL-Exd-1

ResistanceThermometers Ignition Protection Exd TWL-Exd T2 Measuring range: -198 ... +600 °C Pt100 sensor:class F0.3 (B), class F0.15 (A), F0.1 (V3 DIN), F0.03 (V10 DIN) or cryogenic • Output: Resistance or analogue 4-20 mA • Thermowells up to 1000, 3000 respectively 5000 mm (depending on model) • Option: Headtransmitter with HART®-protocol or PROFIBUS®/Fieldbus, display • For ATEX applications, ignition protection Exd KOBOLD companies worldwide: KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. V» Head Office: +49(0)6192 299-0 +49(0)6192 23398 [email protected] www.kobold.com ARGENTINA, AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHILE, CHINA, COLOMBIA, CZECHIA, EGYPT, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, REPUBLIC OF KOREA, ROMANIA, SINGAPORE, SPAIN, SWITZERLAND, TAIWAN, THAILAND, TUNISIA, TURKEY, USA, VIETNAM

 Open the catalog to page 1
TWL-Exd-2

Resistance Thermometers Model TWL Exd Applications The resistance thermometers with thread-, flange- or weldon connection are favourably used for the temperature measurement in liquids, solids and gaseous media. The reliable watertightness of these installation methods for gauge pressure and vacuum is an important criteria for selection. Application areas are located in the air-conditioning and cooling industry, the heating-, furnace-, mechanical- and apparatusconstruction as well as in the complete industry. For all applications in hazardous areas, the instruments are supplied with the ignition...

 Open the catalog to page 2
TWL-Exd-3

4 digit LCD or LED loop powered LCD max. 2.5 V LED 3.3 V at 4 mA 3.7 V at 20 mA Resistance Thermometers Model TWL ExdTechnical Details (continued) Display: Head transmitter: - Output: Analogue output 4-20 mA - Communication: HART®-protocol, PROFIBUS®/ Fieldbus - Minimum meas. span: Standard transmitter 25 °K transmitter with HART® 10 °K transmitter with PROFIBUS®/ Fieldbus 5 °K - Supply voltage: 8 - 35 VDC for standard transmitter and transmitter with HART® 9 - 32 VDC for transmitter with PROFIBUS®/ Fieldbus Order Details (example: TWL-1 1 2 L N D N 5 C A 1) 1 4-wire only for 1 sensor 2) Choose...

 Open the catalog to page 3
TWL-Exd-4

Resistance Thermometers Model TWL Exd Order Details (continued) B = cylindrical, multipart, welded G = cylindrical, bar stock/drilled with stepped shank D = tapered shank, bar stock/drilled Thermowell specification (sensor, thermowell, measuring insert) 4) only for TWL-0 (only thermowell) 0 = without lagging extension "T" 1 = with lagging extension "T" sensor with thermowells A = with standard neckpipe "HL"/ without lagging extension "T" B = with standard neckpipe "HL" and with lagging ext. "T" C 5) = without neckpipe "HL"/ with lagging extension "T" without lagging extension "T" E = with special...

 Open the catalog to page 4
TWL-Exd-5

Resistance Thermometers Model TWL Exd Order Details for Ordering only the Thermowell (example: TWL-0 0 0 0 N B G 4 0 0 0) 1 Immersion length "U", hole diameter "i" and lagging extension "T" must be specified in writing. Please check lengths very precise in order to ensure a perfect match of sensor and thermowell. HL = neckpipe length U = i immersion length thermowell standard 130 mm for TWL-1 (see drawing thermowell) standard 150 mm for TWL-2 H = length see thermowell EL = immersion length LN = screw-in-length by hand EL = U+H -7 mm for thermowell type B (approx. 8.1 mm at NPT) * For Ex-applications...

 Open the catalog to page 5
TWL-Exd-6

Resistance Thermometers Model TWL Exd Dimensions Measuring Insert TWL-3 Dimensions Connection Head with Display HL = neckpipe length EL = immersion length ML = measuring insert length No responsibility taken for errors; subject to change without prior notice.

 Open the catalog to page 6
TWL-Exd-7

Resistance Thermometers Model TWL ExdDimensions Thermowell Model TWL- ... B ... Lagging Extension "T" Cylindrical thermowell, welded, with process connection G-thread (max. PN 25 at 20 °C) No responsibility taken for errors; subject to change without prior notice.

 Open the catalog to page 7
TWL-Exd-8

No responsibility taken for errors; subject to change without prior notice.

 Open the catalog to page 8
TWL-Exd-9

Resistance Thermometers Model TWL ExdDimensions Thermowell Model TWL-...G... Cylindrical thermowell, bar stock/drilled with stepped shank and process connection G-thread (max. PN 100 at 20 °C) Dimensions Thermowell Model TWL-...G... Cylindrical thermowell, bar stock/drilled with stepped shank and process connection NPT-thread (max. PN 100 at 20 °C)

 Open the catalog to page 9
TWL-Exd-10

Process connection Dimensions Thermowell Model TWL-...G...Cylindrical thermowell, bar stock/drilled with stepped shank and process connection for weld-on (max. PN 100 at 20 °C) 10 No responsibility taken for errors; subject to change without prior notice.

 Open the catalog to page 10
TWL-Exd-11

Resistance Thermometers Model TWL ExdDimensions Thermowell Model TWL-...D...Tapered shank, bar stock/drilled thermowell with process connection G-thread (max. PN 250 at 20 °C) Process Dimensions Thermowell Model TWL-...D...Tapered shank, bar stock/drilled thermowell with process connection NPT-thread (max. PN 250 at 20 °C) 1/11-2025

 Open the catalog to page 11
TWL-Exd-12

Dimensions Thermowell Model TWL-...D...Tapered shank, bar stock/drilled thermowell with process connection for weld-on (max. PN 250 at 20 °C) Process No responsibility taken for errors; subject to change without prior notice.

 Open the catalog to page 12
TWL-Exd-13

Resistance Thermometers Model TWL ExdDimensions Thermowell Model TWL-...F...Cylindrical thermowell, bar stock/drilled and process connection G-thread (max. PN 250 at 20 °C) Process Dimensions Thermowell Model TWL-...F...Cylindrical thermowell, bar stock/drilled and process connection NPT-thread (max. PN 250 at 20 °C) 1/11-2025

 Open the catalog to page 13
TWL-Exd-14

Dimensions Thermowell Model TWL-...F...Cylindrical thermowell, bar stock/drilled and process connection for weld-on (max. PN 250 at 20 °C) 14 No responsibility taken for errors; subject to change without prior notice.

 Open the catalog to page 14

All Heinrichs Messtechnik GmbH catalogs and technical brochures

  1. UMC4

    6  Pages

  2. DWF

    4  Pages

  3. NSC

    4  Pages

  4. NGM

    10  Pages

  5. MM

    13  Pages

  6. BA

    7  Pages

  7. PAD

    24  Pages

  8. DOG-4 / -6

    14  Pages

  9. DVE

    8  Pages

  10. PIT UMF2

    5  Pages

  11. MIM

    11  Pages

  12. TSK

    2  Pages

  13. BGN

    12  Pages

  14. TMU-T

    6  Pages

  15. TMU High flow

    7  Pages

  16. TMU

    7  Pages

  17. TMu - W

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.