Heinrichs Heinrichs Messtechnik GmbH Mass-Flow Meter for standard applications • Extreme compact lightweight design. • Measuring ranges from 60 kg/h to 80 000 kg/h. • Immune to external vibrations. • Immune to pipeline induced stresses. • Variety of tube material available. • Extensive selection of process connections. • Optional sensor heating. Technical Information TMU Subject to change without prior notice.
Open the catalog to page 1Heinrichs Heinrichs Messtechnik GmbH The TMU Coriolis flow Sensors utilize the Coriolis principle for the direct measurement of mass flow. The sensor possesses two parallel-arranged tubes, which are continuously force-vibrated at their resonance frequency. When a fluid or gas passes through the tubes, the mass flow momentum in conjunction with the Coriolis effect invokes a change in the tubes deflection, causing the inlet and outlet legs of the tubes to twist out of phase. Coupled with a UMC transmitter, the phase shift is captured and evaluated. The derived linear output is proportional to the...
Open the catalog to page 2Heinrichs Heinrichs Messtechnik GmbH Field housing: Rack mount design: ATEX / lECEx: II (1)2G Ex d [ia Ga] IIC T4-T3 Gb (to be mounted in min. IP54 ATEX certified protective cabinet) Type of protection signal output: • Non-intrinsically safe Type of protection signal output: • Non-intrinsically safe All device sizes are available with standard flanges according to pressure ratings class 150 / 300 and PN40. Depending on the sensor size, other nominal sizes with higher pressure ratings are possible on request. For further information, please contact our sales department. kg/h [lbs/min]_kg/h [lbs/min]_kg/h...
Open the catalog to page 3Heinrichs Heinrichs Messtechnik GmbH Dimensions Local mounted transmitter_Remote mounted transmitter_ Type_mm / inch_mm / inch_mm / inch_mm / inch_mm / inch_mm / inch_mm / inch Installation length dimension "A” see "Order details” on page 5. Heated sensors Sensors equipped with heating plates can have different dimensions depending on the mounted heating plate and the associated connection. Necessary data for the sizing of the meter Nominal Minimum MaXimum Unit Flow rate: _ _ _ _ Process pressure: □abs. / dgauge. _ _ _ _ Process temperature: _ _ _ _ Requirements for the ship approval For the...
Open the catalog to page 4Heinrichs KOBOLD Group Heinrichs Messtechnik GmbH Page 5 Technical Information TMU Subject to change without prior notice. TMU 2G DB 25.01 EN
Open the catalog to page 5Heinrichs KOBOLD Group Heinrichs Messtechnik GmbH 040 6000...60000 kg/h Stainless steel Special, customer specified Technical Information TMU Page 6Subject to change without prior notice.
Open the catalog to page 6Heinrichs KOBOLD Group Heinrichs Messtechnik GmbH Calibration density 1) Must be used with approved transmitter for system approval. Order cable glands separately. 2) Includes ATEX and IECEx approvals. See Requirements for the ship approval on page 4 3) Temperature specification is applicable for whole device only. 4) Applicable only with approval "U". 5) Applicable only with sensor configuration “N" 6) Only in combination with 3.1 certificate. 7) Only in combination with a remote mounted transmitter. Only for approved process conditions. See documentation. 9) Not for device line size 008 10)...