Heinrichs Messtechnik GmbH Coriolis Mass Flow Meter For high flow rates up to 2200 t/h Technical information High flow rates up to 2200 t/h Process connections up to DN400 / 16“ Pressure resistant up to 40 Bar Heating system (optional) Technical Information TMU- High flow Subject to change without prior
Open the catalog to page 1Heinrichs Heinrichs Messtechnik GmbH The TMU Coriolis flow Sensors utilize the Coriolis principle for the direct measurement of mass flow. The sensor possesses two parallel-arranged tubes, which are continuously force-vibrated at their resonance frequency. When a fluid or gas passes through the tubes, the mass flow momentum in conjunction with the Coriolis effect invokes a change in the tubes deflection, causing the inlet and outlet legs of the tubes to twist out of phase. Coupled with a UMC transmitter, the phase shift is captured and evaluated. The derived linear output is proportional to the...
Open the catalog to page 2Heinrichs Heinrichs Messtechnik GmbH Field housing: ATEX / lECEx: II (1)2G Ex d [ia Ga] IIC T4-T3 Gb Type of protection signal output: • Non-intrinsically safe (to be mounted in min. IP54 ATEX certified protective cabinet) Type of protection signal output: • Non-intrinsically safe All device sizes are available with standard flanges according to pressure ratings class 150 / 300 and PN40. Depending on the sensor size, other nominal sizes with higher pressure ratings are possible on request. For further information, please contact our sales department. Type Measuring range max. Nominal (Ap=1bar)...
Open the catalog to page 3Heinrichs Messtechnik GmbH Dimensions local mounted transmitter Dimensions remote mounted transmitter B Remote mounted transmitter Installation length dimension “A” see Order details sensor on page 5. Heated sensors Sensors equipped with heating plates can have different dimensions depending on the mounted heating plate and the associated connection. Necessary data for the sizing of the meter. Medium: Nominal Flow rate: Process pressure: ☐abs. / ☐gauge Process temperature: Density: (at process condition) Viscosity: (at process condition) Requirements for the ship approval For the use of the sensor...
Open the catalog to page 4Heinrichs KOBOLD Group Heinrichs Messtechnik GmbH Model code_Description Page 5 Technical Information TMU- High flow Subject to change without prior notice.
Open the catalog to page 5Heinrichs KOBOLD Group Heinrichs Messtechnik GmbH 200 | 150.000...700.000 kg/h Heater / cooler Special, customer specified Connection for heating / cooling DN25 PN40 Form B1 DIN EN 1092-1 1" Class 150 RF ASME B16.5-2003 1" NPT (f) Special, customer specified Process temperature Sensor cable connection Integral mounted transmittei Integral mounted transmitte! Remote mounted transmitter Remote mounted transmitter Remote mounted transmitter Remote mounted transmitter Remote mounted transmitter Remote mounted transmitter Remote mounted transmitter Remote mounted transmitter -50...100°C (-58...212°F)...
Open the catalog to page 6Heinrichs KOBOLD Group Heinrichs Messtechnik GmbH Approvals 2) Must be used with approved transmitter for system approval. 3) Includes ATEX and IECEx approvals. See Requirements for the ship approval on page 4. 4) Only in combination with 3.1 certificate. 5) Only in combination with a remote mounted transmitter. Page 7 Technical Information TMU- High flowSubject to change without prior notice.