Heinrichs Messtechnik GmbH • Flow measurement and monitoring of turbid, hazardous or flammable liquids • Horizontal and vertical installation possible • Extremely robust design • Outstanding clear reading due to 90° arranged scale • Transmitter with 4...20mA, HART® • Suitability for installation in safety-related measuring circuits according to SIL Technical Information TSK Subject to change without prior notice
Open the catalog to page 1Heinrichs Messtechnik GmbH If a medium flows with sufficient velocity through the vertically or horizontally arranged TSK armature (1), the paddle (2) is pivoted about its pivot point until a state of equilibrium is reached between the force of the medium flowing through and the opposing paddle surface plus the spring force. The angular or equilibrium position of the paddle serves as the measure of the flow rate. It is transmitted by the encapsulated permanent ring magnet (3), which is located at the end of the paddle axis, to the flow rate scale (5) and to the optional electrical transducers,...
Open the catalog to page 2Heinrichs Messtechnik GmbH Design / Variations Aluminum indicator Optimized aluminum indicator Large and well-arranged scale with a 90° angle for optimal reading. Rounded edges and rims ensure a smooth draining of liquids after wet contact. A special anodization and paint finish make the indicator housing suitable for outdoor use. Process connection: wafer style Stainless steel indicator Stainless steel indicator IP65, IP66, IP67 protection for extreme applications Large and well-arranged scale with 90° angle for optimal reading. The round design ensures a smooth draining of liquids after wet...
Open the catalog to page 3Heinrichs Messtechnik GmbH • From DN150 Steel / Stainless steel Special material on request. Special fittings according to customer requirements. Nominal pressure: Higher pressures on request. Process temperature: max. 300°C with forward advanced indication part (TSK-S/H) Environmental temperature: • -40°C ... + 80°C without electrical accessories • -25°C ... +70°C / +80°C with limit switches Measurement deviation: • ±2,5% of the full scale (Liquid/Gas) • ±0,2% additional error with a converter (ES) Display Part Protection class: Electrical Outputs Switch outputs: • max. 2 inductive switch contacts...
Open the catalog to page 4Heinrichs Messtechnik GmbH Technical Information TSK Subject to change without prior notice
Open the catalog to page 5Nominal size Subject to change without prior notice.
Open the catalog to page 6Heinrichs Messtechnik GmbH Certificate and approvals Explosion protection: ATEX (IECEx) Directive BGN (Mechanical Device): Ex-marking: HMT21-4151X (Conformity Statement) II 2G Ex h IIC T2…T6 Gb II 2D Ex h IIIC T85°C/T300°C Db PTB 99 ATEX 2219X PTB 00 ATEX 2049X II 2G Ex ia IIC T6…T1 Gb II 1D Ex ia IIIC T200 135°C Da NEPSI (China): ES: Ex-marking: PESO (India): ES: Ex-marking: Non-electrical devices: for use in potentially explosive atmospheres. Non-electrical equipment: protection by Design safety. General regulations. Intrinsic safety "i". Electromagnetic compatibility: EMV Directive EMC requirements....
Open the catalog to page 7Heinrichs Messtechnik GmbH Dimensions Aluminum display part and horizontal flow direction Stainless Steel display part and horizontal flow direction Version for vertical flow directions Technical Information TSK Subject to change without prior notice.
Open the catalog to page 8Nominal size DN/ASME Technical Information TSK Subject to change without prior notice
Open the catalog to page 9Heinrichs Messtechnik GmbH Technical Information TSKSubject to change without prior notice.
Open the catalog to page 10Heinrichs Messtechnik GmbH Flow direction 1) Recommended for solids content in the medium 2) Screw-in thread in base plate M20x1,5, other threads on request 3) SIL 1 - IEC 61508-2:2010 conformity confirmed by EXIDA 4) SIL 1 - IEC 61508-2:2000 conformity confirmed by EXIDA 5) SIL 2 - IEC 61508-2:2000 conformity confirmed by EXIDA 6) SIL conformity only with "Accessories" option "S" 7) Only in combination with "electrical output" for options "3", "4", "6", "7", "8" 8) Combination of stainless-steel indicator part with ES and counter module not possible. Only for flow direction bottom to top. 9)...