Oscillation Flow Meter Connection: flange DN 25 ... DN 200, ANSI 1"... 8" Material: stainless steel Long-term stability Options: flow computer, analogue and pulse outputs KOBOLD companies worldwide: AUSTRALIA, AUSTRIA, BELGIUM, BULGARIA, CANADA, CHINA, CZECHIA, FRANCE, GERMANY, GREAT BRITAIN, HUNGARY, INDIA, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHERLANDS, PERU, POLAND, Republic of Korea, SPAIN, SWITZERLAND, THAILAND, TUNISIA, turkey, USA, VIETNAM KOBOLD Messring GmbH Nordring 22-24 D-65719 Hofheim/Ts. Head Office: +49(0)6192 299-0 +49(0)6192 23398 [email protected] www.kobold.co
Open the catalog to page 1The KOBOLD flow meters DOG-4/-6 are used for flow measurement of gases. The DOG-6 comes with a special sensor construction and an inclined measuring head. This inclination optimises the condensate drain specifically for applications involving wet gases, e.g. biogas. The medium flows through an orifice in a tube. Bypass bores are located at the sides. The dynamic pressure at the orifice causes part of the gas volumetric flow to flow into the bypass. The division ratio remains constant over the whole measuring range. Technical Details Measuring accuracy: Media temperature: Ambient temperature Operating...
Open the catalog to page 2Oscillation Flow Meter Model DOG-4 / -6 Electronics DOG-...A / B / C / D / E / F / R (Sensor with / without ATEX / IECEx certification) Power supply: A: 230 VAC ±10 %, 50 … 60 Hz (with ATEX / IECEx) B: 230 VAC ±10 %, 50 … 60 Hz (without ATEX / IECEx) C: 110 VAC ±10 %, 50 … 60 Hz (without ATEX / IECEx) D: 110 VAC ±10 %, 50 … 60 Hz (with ATEX / IECEx) E: 24 VAC ±10 %, 50 … 60 Hz (without ATEX / IECEx) F: 24 VAC ±10 %, 50 … 60 Hz (with ATEX / IECEx) R: 24 VDC ±20 %, (without ATEX / IECEx) Input: platinum sensor (Allowed distance: max. 50 m to sensor) Output: opto coupler, frequency linear to flow...
Open the catalog to page 3Oscillation Flow Meter Model DOG-4 / -6 Elektronic Options (continuation) (optional, other Modbus versions on request) Analogue output: Pulse output: 10-Bit resolution, 3-wire PNP, 24 VDC active max. 50 mA, scaled according to linearised accumulated total (e. g. pulse every 12 litres) pulse duration: user defined 0.001 s . 10 s max. frequency 500 Hz IP 65 Electronics DOG-...M / N / O / P (Sensor without / with ATEX/ IECEx certification and Flow computer) Display: alphanumeric LCD, UV-resistant with displayed functions: Compensated flow rate Compensated total resettable Accumulated total Actual...
Open the catalog to page 4Order Details for DOG-4 for dry gases (Example: DOG-42S0S50 0 A0 0) Measuring range 0 = without ball valve 1 = with ball valve Ball valve = frequency output, 230 Vac = as 'B0', with ATEX/IECEx = frequency output, 110 Vac = as 'C0', with ATEX/IECEx = frequency output, 24 Vac = as 'E0', with ATEX/IECEx = frequency output, 24 Vdc = unit counter, pulse output, analogue output, 230 Vac = as 'G0', with ATEX/IECEx = unit counter, pulse output, analogue output, 110 Vac = as 'I0', with ATEX/IECEx = unit counter, pulse output, analogue output, 24 VDC = flow computer, pulse output, analogue output, 230...
Open the catalog to page 5Oscillation Flow Meter Model DOG-4 / -6 Order Details for DOG-4 for dry gases (Example: DOG-42S0S50 0 A0 0) (continued) Measuring range Model Material stainless steel Pressure rating flanges * [PN] Connection flange [size/type] Ball valve 0 = wihout ball valve 1 = with ball valve E0 = frequency output, 24 VAC F0 = as 'E0', with ATEX/IECEx R0 = frequency output, 24 VDC G0 = unit counter, pulse output, analogue output, 230 VAC K0 = as 'I0', with ATEX/IECEx L0 = unit counter, pulse output, analogue output, 24 VDC I0 = unit counter, pulse output, analogue output, 110 VAC 0 = without Y = special option...
Open the catalog to page 6Order Details for DOG-4 for dry gases (Example: DOG-42F0F80 0 A0 0) (continued) Measuring range 1 = with ball valve Ball valve Electronics Options B0 = frequency output, 230 Vac A0 = as 'B0', with ATEX/IECEx C0 = frequency output, 110 Vac D0 = as 'C0', with ATEX/IECEx E0 = frequency output, 24 Vac F0 = as 'E0', with ATEX/IECEx R0 = frequency output, 24 VDc G0 = unit counter, pulse output, analogue output, 230 Vac H0 = as 'G0', with ATEX/IECEx I0 = unit counter, pulse output, analogue output, 110 Vac K0 = as 'I0', with ATEX/IECEx L0 = unit counter, pulse output, analogue output, 24 Vdc M0 = flow...
Open the catalog to page 7Oscillation Flow Meter Model DOG-4 / -6 Order Details for DOG-6 for wet gases (Example: DOG-62S0S50 0 B0 0) Measuring range 0 = without ball valve 1 = with ball valve Ball valve B0 = frequency output, 230 Vac A0 = as 'B0', with ATEX/IECEx C0 = frequency output, 110 Vac D0 = as 'C0', with ATEX/IECEx E0 = frequency output, 24 VAC F0 = as 'E0', with ATEX/IECEx R0 = frequency output, 24 VDC G0 = unit counter, pulse output, analogue output, 230 Vac H0 = as 'G0', with ATEX/IECEx I0 = unit counter, pulse output, analogue output, 110 Vac K0 = as 'I0', with ATEX/IECEx L0 = unit counter, pulse output,...
Open the catalog to page 8Order Details for DOG-6 for wet gases (Example: DOG-62S0S50 0 B0 0) (continued) Measuring range 0 = without ball valve 1 = with ball valve 1 = with ball valve Ball valve Electronics Options B0 = frequency output, 230 Vac A0 = as 'B0', with ATEX/IECEx C0 = frequency output, 110 Vac D0 = as 'C0', with ATEX/IECEx E0 = frequency output, 24 VAC F0 = as 'E0', with ATEX/IECEx R0 = frequency output, 24 VDC G0 = unit counter, pulse output, analogue output, 230 Vac H0 = as 'G0', with ATEX/IECEx I0 = unit counter, pulse output, analogue output, 110 Vac K0 = as 'I0', with ATEX/IECEx L0 = unit counter, pulse...
Open the catalog to page 9Oscillation Flow Meter Model DOG-4 / -6 Order Details Accessories/Spare parts for DOG-4/-6 Order Code DOG-4 spare sensor with transport sleeve, 10 mm plate DOG-4 spare sensor with transport sleeve, 15 mm plate DOG-6 spare sensor with transport sleeve DOG-4/ -6 calibration software with PC interface with USB connection No responsibility taken for errors; subject to change without prior notice.
Open the catalog to page 10Oscillation Flow Meter Model DOG-4 / -6 Pressure Loss/Flow The diagram applies for gases with a density of air at NPT (0°C and 1013.25 mbar). The pressure loss is always proportional to the density of the gas. For example, the pressure loss doubles at 100% higher operating pressure. Pressure drop [mbar] Calculating the Actual Density The actual density can be calculated with the following formula: density at 1 bar abs. and 0 °C (= 273 K) temperature in K (= °C + 273 for example 20 °C = 273 + 20 = 293 K) 273 K operating pressure in bar (absolute pressure) Calculating the Norm Flow QN = Q ∙ No...