video corpo

Transit Time Ultrasonic Flow Meters TFX-500w Clamp-On Meter
8Pages

{{requestButtons}}

Catalog excerpts

Transit Time Ultrasonic Flow Meters TFX-500w Clamp-On Meter - 1

Transit Time Ultrasonic Flow Meters TFX-500w Clamp-On Meter DESCRIPTION The TFX-500w transit time ultrasonic flow meter measures volumetric flow of clean water in pipes 10 in. or smaller. By clamping on the outside of the pipe, the ultrasonic meter installs without cutting or tapping the pipe. Clamp-on, non-invasive flow meter Bidirectional flow measurement system Measures flow rate, total and velocity of water flow Set up the meter through keypad interface or with SoloCUE® Flow Device Manager software Compact enclosure uses large, easy-to-read graphical display Modbus RTU or BACnet MS/TP over RS485 and BEACON®/AquaCUE® connectivity Reduces installation costs, especially retrofits ◊ Installs without cutting into the pipe Eliminates flanges and pipe fittings Eliminates draining and air purging Eliminates ingress or leak points in pipes No moving parts to maintain No pressure head loss APPLICATION The TFX-500w meter is well suited for building automation, water distribution and wastewater collection in new and retrofit applications. In addition to having lower installation costs than an inline flow meter, the TFX-500w meter can be installed while the system continues to operate without interruption. By connecting the TFX-500w meter to Badger Meter® AquaCUE or BEACON analytics cloud service, the meter becomes part of a system that tracks and monitors water use for commercial buildings, campuses and other large facilities. OPERATION Transit time flow meters use two transducers that function as both ultrasonic transmitters and receivers. The flow meters operate by alternately transmitting and receiving a frequency-modulated burst of sound energy between the two transducers. The burst is first transmitted in the direction of fluid flow and then against fluid flow. Since sound energy in a moving liquid is carried faster when it travels in the direction of fluid flow (downstream) than it does when it travels against fluid flow (upstream), a differential in the times of flight will occur. The sound’s time-of-flight is accurately measured in both directions and the difference in time-of-flight calculated. Potable water Reclaimed water Chiller water Boiler feed water Make-up water Condenser water

Open the catalog to page 1
Transit Time Ultrasonic Flow Meters TFX-500w Clamp-On Meter - 2

SPECIFICATIONS System Liquid Types Water containing small amounts of suspended solids or gas bubbles Velocity Range Flow Accuracy > 2 in. (50 mm) ±1% of reading or ±0.01 ft/s (0.003 m/s), whichever is greater 1…2 in. (25…50 mm) ±1% of reading ±0.03 ft/s (0.01 m/s) 3/4 in. (20 mm) and smaller are accurate to ±1% full scale Transducer Type Clamp-on ultrasonics Certifications Remote mount transmitter and integral mount transmitter with transducers General Safety (option): FM Class 3810:2018, ANSI/ISA 61010-1:2012, ANSI/IEC 60529:2004, CAN/CSA-C22.2 No. 61010-1:2012, CSA C22.2 No. 60529:2005...

Open the catalog to page 2
Transit Time Ultrasonic Flow Meters TFX-500w Clamp-On Meter - 3

Specifications Transducers Model CA…CT, Fixed small pipe RZ (IP54), Standard pipe NZ (IP67), Standard pipe WZ (IP68), Standard pipe, Submersible JZ, KZ (IP54), Standard pipe, Integrated rail Construction CPVC, Ultem, Nylon cord grip Polyethylene cable jacket; –40…194° F (–40…90° C) 1 PBT glass filled, Ultem®, Nylon cord grip PVC cable jacket; –40…250° F (–40…121° C) CPVC, Ultem, Nylon cord grip Polyethylene cable jacket; –40…194° F (–40…90° C) CPVC, Ultem, Nylon cord grip Polyethylene cable jacket; –40…194° F (–40…90° C) PBT glass filled, Ultem®, Nylon cord grip PVC cable jacket; –40…250° F...

Open the catalog to page 3
Transit Time Ultrasonic Flow Meters TFX-500w Clamp-On Meter - 4

DIMENSIONS TFX-500w Meter Enclosure, Integral and Remote, Front View Integral Enclosure Side View Remote Enclosure Side View 2.68 in. (68.07) Transducers Remote System with Standard Pipes NZ/RZ/WZ (W, V or Z mount) RZ (optional alignment rail) Model RZ NZ, WZ Easy Rail JZ/KZ (W or V mount)

Open the catalog to page 4
Transit Time Ultrasonic Flow Meters TFX-500w Clamp-On Meter - 5

Dimensions Remote System with Small Pipes CA…CT CA…CT (except CF and CL) Pipes and Tubing 1/2…2 in. CF and CL U-Bolt Connections ANSI Pipe and Copper Tubing 2 in. Models Integral System CA…CT CA…CT (except CF and CL) Pipe Size Pipe Material * Varies due to U-bolt configuration

Open the catalog to page 5
Transit Time Ultrasonic Flow Meters TFX-500w Clamp-On Meter - 6

Part Number Construction PART NUMBER CONSTRUCTION DW Transit Time: Pipes ≤ 2 in. CERTIFICATION General Area, CE TRANSDUCER TYPE 1/2 in. ANSI pipe 1/2 in. Stainless Steel Tube 3/4 in. Stainless Steel Tube 1 in. Stainless Steel Tube 1-1/4 in. Stainless Steel Tube 1-1/2 in. Stainless Steel Tube 2 in. Stainless Steel Tube TRANSMITTER TYPE 24V DC | Meter Mounted DISPLAY Standard No display with keypad REMOTE CABLE LENGTH None (Meter Mounted) CONDUIT TYPE AND LENGTH UNITS OF MEASURE: TOTALIZER / FLOW RATE Gallons/gallons per minute Gallons/cubic feet per minute Cubic Meters/cubic meters per...

Open the catalog to page 6
Transit Time Ultrasonic Flow Meters TFX-500w Clamp-On Meter - 7

Part Number Construction Transit Time: Pipes > 2 in. CERTIFICATIONS General Area, CE TRANSDUCER TYPE Easy Rail | 2.5…6 in. (65…150 mm) Pipes Easy Rail | 2.5…10 in. (65…250 mm) Pipes DTTN (Submersible) | 2.5…10 in. (65…250 mm) Pipes TRANSMITTER TYPE 24V DC Remote Mounted DISPLAY Standard No display with keypad REMOTE CABLE LENGTH 15 ft (4.57 m) CONDUIT AND CABLE LENGTH UNITS OF MEASURE: TOTALIZER / FLOW RATE Gallons/gallons per minute Gallons/cubic feet per minute Cubic Meters/cubic meters per minute Cubic Meters/cubic meters per hour Cubic Feet/gallons per minute Cubic Feet/cubic feet per...

Open the catalog to page 7
Transit Time Ultrasonic Flow Meters TFX-500w Clamp-On Meter - 8

Transit Time Ultrasonic Flow Meters, TFX-500w Clamp-On Meter PARTS AND ACCESSORIES Couplant Part Number D002-2011-001 D002-2011-002 Description Dow Corning® Molykote® 111 Grease; 5.3 oz Tube; 150° F (65° C) Dow Corning 732; Permanent Mount; 356° F (180° C) Dow 111 grease is included with transducers. Power Supplies Part Number 68334-001 68334-002 Description Wall Plug; 100…264V AC In; 24V DC Out; -20…50° C Module; 85…264V AC In; 24V DC Out; -30…70° C For ordering transducers and transmitter separately, please contact factory. Control. Manage. Optimize. Dynasonics is a registered trademark...