Overview: The document provides detailed technical specifications and operational guidelines for the eco-friendly safety valve SV422, designed for hot water systems. It is primarily used as a pressure safeguard in gas heat exchangers.
Specifications: The SV422 is installed at the inlet and outlet of gas pressure-resistant heat exchangers. It operates with a diameter up to DN200, pressure levels up to class 1500, and an operating temperature up to 120°C. The design complies with PED2014/68/EU and AD2000 standards, with CE marking and DVGW approval.
Functional Description: The valve blocks the flow to and from the heat generator if pressure increases, preventing system damage. It remains closed under high pressure and reopens once pressure normalizes. The valve structure ensures reliable operation and easy functional testing.
Design and Calculation: The valve is designed with continuous ISO9001 quality assurance. It includes preliminary examinations and material testing. Optional accessories include remote sensors and test devices.
Technical Data: The valve is made from C-steel and stainless steel, with EPDM seals. It is explosion-proof under normal conditions and does not fall under the ATEX Directive unless modified.
Installation and Maintenance: Proper installation requires adherence to HEATenergy’s instructions and national regulations. The valve can be insulated, but position sensors should not be.
Contact Information: The document lists contact details for various HEAT Holding International GmbH offices across Europe.
See more

Catalog excerpts

hot water safety shut off valve SV422-1

SAFETY VALVE SV 422 for hot water HEAT Holding International GmbH

 Open the catalog to page 1
hot water safety shut off valve SV422-2

Hot water safety shut-off valve SV422    For installation upstream of gas heat exchangers as pressure safeguard for the entire heat circuit Situated at the inlet and outlet nozzles of the heating medium at the gas pressure-resistant heat exchanger Internal medium actuated with reliable triggering in case of pressure increase in the water system The SV422 reliably blocks only the damaged heat exchanger from the system in the event of leakage If there is only a minimal loss of water, the one reserve heat exchanger continues to function reliably There is no freezing of the reserve controlled...

 Open the catalog to page 2
hot water safety shut off valve SV422-3

Design in accordance with PED2014/68/EU, AD2000; with CE marking, DVGW approval Continuous application of ISO9001 with regularly audited quality system Preliminary examination/construction testing, material testing, non-destructive material testing in accordance with design standard Acceptance by experts such as TÜV, DVGW, etc. Control device with water stop Screen seal to repel water contamination Threaded bolts with certificate suitable for the pressure level ordered Remote transmission sensor in EEx(i) design Test and control device with connection ball valves, pressure gauges, etc. Flanges...

 Open the catalog to page 3
hot water safety shut off valve SV422-4

Triggering behaviour SV422 Heating circuit system pressure Pressure curve in the heat exchanger p3 Switching pressure Operating pressure Time Leakage Closing pressure of the control device Gas entry into the heating system Closing process of the actuator Opening pressure of the control device Pressure loss depending on the flow rate of the SV422 HEAT Holding International GmbH

 Open the catalog to page 4
hot water safety shut off valve SV422-5

Technical data Design pressure Ps Intermediate flange connection EN1092-1 DN25, DN50, DN80 > PN16, PN25, PN40, ANSI B16.5 Standard version RF, optional RTJ for class 600/900/1500 1”, 2”, 3” 4”, 6”, 8” > class 600RF, class 900RF, class 1500RF Housing: C-steel tenifer treated Interior parts: Stainless steel Seals: EPDM Control unit: stainless steel PED2014/68/EU, AD2000, DVGW/CE marking, EN10204 3.1, DVGW Design only similar to EN 14382 The SV422 device has no potential sources of ignition of its own when used as intended. Consequently, the WW-SSV does not fall within the scope of the ATEX Directive...

 Open the catalog to page 5
hot water safety shut off valve SV422-6

Dimensions in accordance with DN and PN – accessories such as sensors and test equipment are not included HEAT Holding International GmbH

 Open the catalog to page 6
hot water safety shut off valve SV422-7

Arrangement of the WW-SSV SV422 in the overall system Familiarisation with and consideration of HEATenergy’s SV422 operating and maintenance instructions are required for precise installation instructions. In addition, all appropriate national/customer regulations, as well as DVGW regulations G495 and G499, must be observed. The valves can usually be insulated, the position sensors must not be insulated. Heizraum Heating room Gas pressure control room Gas-Druckregelraum k Supply Vorlauf Return Rücklauf Hot water safety shut-off valve SV422 with control device Mating flanges according to ordered...

 Open the catalog to page 7
hot water safety shut off valve SV422-8

HEAT energy GmbH A-2362 Biedermannsdorf, Rheinboldtstraße 16 Tel.: +43 664 824 1616 [email protected] www.heatgroup.at HEAT energy Kft. H-8800 Nagykanizsa, Erdész u. 28. Tel.: +36 93 537 140 Fax: +36 93 537 142 [email protected] www.heatgroup.hu HEAT gaswärmetechnische Anlagen GmbH D-34119 Kassel, Querallee 41 Tel.: +49 561 288 56-0 Fax: +49 561 288 56-20 [email protected] www.heatgroup.de LOG Oiltools Kft. H-8800 Nagykanizsa, Erdész u. 28. Tel.: +36 93 537 140 Fax: +36 93 537 142 [email protected] www.logoiltools.hu HEAT Romania S.R.L. RO-547 185 Cristesti (Targu Mures) Strada...

 Open the catalog to page 8
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.