1. Catalogs
  2. Headline Filters
  3. Drain Vessels & Float Drains

Drain Vessels & Float Drains

Drain Vessels & Float Drains

Product catalog summary
Specifications:
  • Housing Models: DV127G, DV137G, DV147G, FD130
  • Port Size: NPT 1/8” for DV127G, NPT 1/4” for others
  • Maximum Pressure: 7 Bar for DV models, 15 Bar for FD130
  • Maximum Temperature: 100ºC for all models
  • Materials of Construction: 316L Stainless Steel for head, base, and internals; Pyrex for bowl in DV models, 316L for FD130; Viton for gaskets
Principal Dimensions:
  • Dimensions (mm): A: 10 (FD130 only), B: 40-56, C: 90-232, D: 50-204
  • Volume: 30-255 cc
  • Weight: 0.2-0.8 kg
Accessories:
  • Gasket Set: GV127 for DV127G, GV137 for DV137G and DV147G, GVFD130 for FD130
Procedures:
  • The FD130 automatic float drain is used in positive pressure systems to remove large quantities of liquid. It operates by allowing liquid to collect and rise, which opens a valve to drain the liquid.
  • For negative pressure applications, drain vessels are used to manually collect and isolate liquid from the system.
Recommendations:
  • FD130 is suitable for systems with positive pressure between 1 bar and 15 bar.
Notes:
  • Material abbreviations: 316L = 316L Stainless Steel, Pyrex = Borosilicate Glass
See more

Catalog excerpts

Drain Vessels & Float Drains-1

Drain Vessels & Float Drains FD130 Float Drain automatically removes liquids from the filter Drain Vessels are used to manually drain liquids from filters under negative pressure The FD130 automatic float drain is used in positive pressure systems to remove large quantities of liquid. The drain is added to the drain port of a filter housing fitted with a coalescing filter element. The liquid drains from the housing into the automatic float drain and collects in the bottom. As the level of the liquid rises, the float will open a valve, and the liquid drains out. The FD130 automatic float drain is suitable for use in systems with a positive pressure between 1 bar and 15 bar. For applications under a negative pressure, drain vessels can be used to collect large quantities of liquid. Valves installed at each end of the drain vessel will allow liquid to be isolated from the system and drained. Principal Specifications Housing Model Head, Base & Internals Maximum Pressure - Bar Maximum Temperature - ºC Materials of Construction (1) Principal Dimensions (1) Material abbreviations, 316L = 316L Stainless steel, Pyrex = Borosilicate glass

 Open the catalog to page 1
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.