labVF6-Iso II

labVF6-Iso II

labVF6-Iso II

Product catalog summary
Overview: The labVF6-Iso II is a 6-channel input module designed by HEAD acoustics GmbH for connecting voltage and IEPE/ICP sensors. It features electrical isolation of inputs, high input impedance, and compatibility with the HEADlink 2.0 transmission protocol, making it suitable for electromagnetically demanding environments.
Key Features:
  • 6-channel input with HEADlink 2.0 protocol.
  • Electrical isolation to prevent ground loops.
  • High input impedance: 10 MΩ DC and 1 MΩ AC.
  • Maximum sampling rate of 204.8 kHz.
  • Switchable coupling options: DC, AC, ICP, ICP-DC.
  • Measurement ranges: 30 mV to 30 V.
  • Analog lowpass and highpass filters available.
  • Overvoltage detection for channel protection.
  • Power supply via HEADlink, rugged and compact design.
Applications: Suitable for fast data acquisition in environments with electromagnetic interference, especially when using sensors without case isolation.
Technical Details:
  • Electrical isolation for each input and from the HEADlink interface.
  • Flexible system sampling rate up to 204.8 kHz.
  • Powered by connected controllers or systems, no dedicated power supply needed.
  • Operable via ArtemiS SUITE software or a browser-based interface.
Control and Power Supply: Compatible with various controllers and systems using HEADlink protocols. Power supplied via HEADlink, with optional supply modules for self-sufficient operation.
Data Acquisition: Connects sensors via BNC connectors, supporting voltage, IEPE/ICP sensors, and more. Offers a range of measurement and filtering options.
Scope of Delivery and Accessories: Includes the labVF6-Iso II module and requires compatible controllers and cables. Optional supply modules and power adapters are recommended.
Software Accessories: Requires ArtemiS SUITE for configuration and control, with various modules available for data preparation and analysis.
General Information: Provides detailed specifications on connectors, power consumption, sampling rates, and environmental conditions. Emphasizes the module's high dynamic range and noise performance.
See more

Catalog excerpts

labVF6-Iso II-1

DATA SHEET labVF6-Iso II labVF6-Iso II is a 6-channel HEADlab input module with HEADlink 2.0 transmission protocol for connecting voltage and IEPE/ICP sensors. The six high-impedance inputs are electrically isolated from each other and also from the digital HEADlink interface, enabling the module to be used even in electromagnetically demanding environments. HEAD acoustics GmbH Code 3757, Rev. 04, subject to change, last update: 01/26

 Open the catalog to page 1
labVF6-Iso II-2

6-channel HEADlab input module with HEADlink 2.0 labVF6-Iso II provides six high-impedance inputs that are electrically isolated from each other. Electrical isolation prevents ground loops and extends the range of application to electromagnetically demanding environments. In addition, the module is characterized by a high input impedance, switchable lowpass filters, and flexibly adjustable sampling rates of 2.048 kHz to 204.8 kHz. Electrical isolation of the inputs from each other and also from the digital HEADlink interface High input impedance › 10 MΩ DC, e.g., for resolvers › 1 MΩ AC, for...

 Open the catalog to page 2
labVF6-Iso II-3

DETAILS Electrical isolation Power supply labVF6-Iso II provides 6 BNC inputs for direct connection of voltage or IEPE/ICP sensors. To prevent ground loops, each input is electrically isolated from both the grounds of the other inputs and the HEADlink interface. This enables sensors without case isolation to be used in electromagnetically demanding environments. labVF6-Iso II does not require a dedicated power supply, as the input module and all connected modules (e.g., a labCTRL II.1 controller with up to ten modules) are powered by the controller, the compact system, or other connected devices....

 Open the catalog to page 3
labVF6-Iso II-4

CONNECTION OF SENSORSVia BNC > Voltage or IEPE/ICP sensors (TEDS) > BHM III.3 mobile headset microphone for binaural recordings > HSU III.2 artificial head microphone CONTROL / POWER SUPPLY CONNECTION TO CONTROLLER / FRONTEND / SYSTEMHEAD/znk Protocol 2.0 via HEAD/znk > /abCTRL II.1 controller > /abHSU high-end 2-channel frontend (from firmware version 2.1) > HMS V digital head measurement system (from firmware version 2.1) POWER SUPPLYVia HEAD/znk HEAD/znk Protocol 1.0 via HEAD/znk > /abCTRL I.2 and /abCTRL I.1 controllers > /abHSU 2-channel frontend (up to firmware version 2.1) > HMS V digital...

 Open the catalog to page 4
labVF6-Iso II-5

3757 /abVF6-Iso II 6-channel HEAD/ab input module with HEAD/ink 2.0 transmission protocol for connecting voltage and IEPE/ICP sensors Hardware AccessoriesRequired (One of the Controllers Listed Below, ...) 3704 HEAD acoustics GmbH 5 Code 3757, Rev. 04, subject to change, last update: 01/26

 Open the catalog to page 5
labVF6-Iso II-6

Further modules of ArtemiS SUITE (see ArtemiS SUITE Overview data sheet) HEAD acoustics GmbH 6 Code 3757, Rev. 04, subject to change, last update: 01/26

 Open the catalog to page 6
labVF6-Iso II-7

Plug connector 1 x LEMO 8-pin HEAD/ink version HEAD/ink 1.0, HEAD/ink 2.0 Maximum cable length 60 m HEAD acoustics GmbH 7 Code 3757, Rev. 04, subject to change, last update: 01/26

 Open the catalog to page 7
labVF6-Iso II-8

1 Valid for: ambient temperature 23 °C, 73.4 °F (±3 °C, ±5.4 °F ), operating duration >1 h. Vibration excitation of the device may cause deviations. All measurement ranges are calibrated at the factory. In addition, the measurement ranges 300 mVP to 30 Vp can be calibrated in the accredited calibration laboratory of HEAD acoustics GmbH in accordance with DIN EN ISO 17025. HEAD acoustics GmbH 8 Code 3757, Rev. 04, subject to change, last update: 01/26

 Open the catalog to page 8
labVF6-Iso II-9

1 Valid for: ambient temperature 23 °C, 73.4 °F (±3 °C, ±5.4 °F ), operating duration >1 h. Vibration excitation of the device may cause deviations. All measurement ranges are calibrated at the factory. In addition, the measurement ranges 300 mVP to 30 Vp can be calibrated in the accredited calibration laboratory of HEAD acoustics GmbH in accordance with DIN EN ISO 17025. There is no standardized calculation method for the term "dynamics". This is why the Signal-to-Noise Ratio value (SNR or S/N) is specified for ZabVF6-Iso II. This value is calculated based on the level of a sinusoidal tone with...

 Open the catalog to page 9

All HEAD acoustics GmbH catalogs and technical brochures

  1. HRT I

    8  Pages

  2. HRR I

    3  Pages

  3. labSAR I

    6  Pages

  4. labM6 II

    7  Pages

  5. labV8x3-Iso II

    11  Pages

  6. labV24 II

    7  Pages

  7. labV12 II

    7  Pages

  8. labVF6 II

    7  Pages

  9. labCOMPACT12 II

    10  Pages

  10. BHS II

    4  Pages

  11. RC X.1

    3  Pages

  12. SQuadriga III

    26  Pages

  13. MCP I.24

    1  Page

  14. DO-160

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.