The labM6 II is a second-generation input module from HEAD acoustics, designed for high-dynamic range data acquisition using up to six condenser microphones. It features the HEADlink 2.0 transmission protocol, allowing for a maximum sampling rate of 204.8 kHz. The module supports both HD wide-range inputs and conventional fixed measurement ranges from 30 mV to 30 V. It includes overload detection, switchable coupling options (DC, AC, ICP, ICP-DC), and analog highpass filters.

Key Features
  • Connection for up to six condenser microphones.
  • Overload detection with automatic channel switch-off.
  • Switchable coupling: DC, AC, ICP, ICP-DC.
  • Maximum sampling rate of 204.8 kHz.
  • Analog highpass filters: 1.58 Hz (1st order), 22 Hz (2nd order).
  • Electrical isolation from other modules and PC interface.
  • Noiseless, rugged design with integrated locking mechanism.

Applications
The module is suitable for data acquisition with low-noise microphones and supports a wide range of dynamic signals without requiring setting changes due to overload or low volume recordings.

Scope of Delivery
The package includes the labM6 II module and requires compatible controllers or frontends, such as the labCTRL II.1 or labCOMPACT systems, and HEADlink cables.

Technical Data
  • Connections: 6 x voltage/Mic In, 1 x HEADlink.
  • Supply voltage: 10 VDC to 28 VDC.
  • Max power consumption: 12 W.
  • Operating temperature: -10 °C to +60 °C.
  • Dimensions: 148 mm x 48 mm x 173 mm.
  • Weight: 758 g.
  • Protection class: III according to EN61140.
  • Shock and vibration resistance according to EN 60068 standards.

Analog Input Specifications
  • Plug connector: 6 x LEMO 7-pin.
  • Measurement ranges: 0.03 VP to 30 VP, HD mode 10 VP.
  • Input impedance: 100 kΩ.
  • Resolution: 32 bits.
  • Electrical isolation: Yes.

Contact Information
HEAD acoustics GmbH, Ebertstrasse 30a, 52134 Herzogenrath, Germany. Phone: +49 2407 577-0, Email: [email protected], Website: www.head-acoustics.com
See more

Catalog excerpts

labM6 II-1

6-channel voltage/microphone input module of the second HEADlab generation with HD wide range input (high dynamics) HEAD acoustics GmbH 1 Code 3754, Rev. 2, subject to change, last update: 05/25

 Open the catalog to page 1
labM6 II-2

Code 3754 Second-generation HEADlab input module › HEADlink 2.0 transmission protocol labM6 II is a second-generation HEADlab input module that, thanks to the HEADlink 2.0 transmission protocol, provides twice the sampling rate with the same number of channels compared to HEADlink 1.0. In conjunction with labCTRL II.1, the secondgeneration HEADlab controller, labM6 II delivers a maximum sampling rate of 204.8 kHz. Connection of up to six condenser microphones to use all channels either as HD wide-range inputs or conventionally with fixed measurement ranges from 30 mV to 30 V. Overload detection...

 Open the catalog to page 2
labM6 II-3

6-channel voltage/microphone input module of the second HEADlab generation with HD wide-range input (high dynamics) Hardware AccessoriesRequired (one of the controllers/frontends listed below) 3701 HEAD acoustics GmbH 3 Code 3754, Rev. 2, subject to change, last update: 05/25

 Open the catalog to page 3
labM6 II-4

> High-end 2-channel frontend /abHSU > Mobile 8-channel recording and playback system SQuadriga III > HEAD VISOR microphone array VMA V Power supply Data Acquisition Connecting Sensors Condenser microphones Head-shoulder units HSU III.2, HSU III.3 Binaural headset BHS II Voltage/ICP sensors HEAD acoustics GmbH 4 Code 3754, Rev. 2, subject to change, last update: 05/25

 Open the catalog to page 4
labM6 II-5

HEAD acoustics GmbH 5 Code 3754, Rev. 2, subject to change, last update: 05/25

 Open the catalog to page 5
labM6 II-6

HEAD acoustics GmbH 6 Code 3754, Rev. 2, subject to change, last update: 05/25

 Open the catalog to page 6
labM6 II-7

Valid for: Ambient temperature 23 °C, 73.4 °F (±3 °C, ±5.4 °F), operating time >1 h. Vibration excitation may cause deviations. There is no standardized calculation method for the term "dynamics". This is why the signal-to-noise ratio value (SNR or S/N) is stated for labM6 II. It is calculated based on the level of a sinusoidal tone with maximum modulation in relation to the full bandwidth noise floor level of the labM6 II module, measured over the entire relevant frequency range. In some literature, the term "dynamics" is used by analogy with the S/N value, however, this is often based on a...

 Open the catalog to page 7

All HEAD acoustics GmbH catalogs and technical brochures

  1. HRT I

    8  Pages

  2. HRR I

    3  Pages

  3. labSAR I

    6  Pages

  4. labV8x3-Iso II

    11  Pages

  5. labV24 II

    7  Pages

  6. labV12 II

    7  Pages

  7. labVF6-Iso II

    9  Pages

  8. labVF6 II

    7  Pages

  9. labCOMPACT12 II

    10  Pages

  10. BHS II

    4  Pages

  11. RC X.1

    3  Pages

  12. SQuadriga III

    26  Pages

  13. MCP I.24

    1  Page

  14. DO-160

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.