labCOMPACT12 II

labCOMPACT12 II
1 / 10 PagesView full catalog

labCOMPACT12 II

Product catalog summary
Overview
The labCOMPACT12 II and labCOMPACT24 II are compact multi-channel data acquisition systems by HEAD acoustics, designed for connecting analog and ICP sensors. They offer 12 or 24 channels with a maximum sampling rate of 204.8 kHz. Key features include USB 3.1 Gen. 1 and Gigabit LAN for data transfer, switchable coupling options, and high input impedance.
Key Features
  • Connects up to 12 or 24 analog and ICP sensors.
  • Data transfer via USB 3.1 Gen. 1 and Gigabit LAN.
  • Maximum sampling rate of 204.8 kHz.
  • Switchable coupling: DC, AC, ICP, ICP-DC.
  • High signal-to-noise ratio: 109 dB(A).
  • Control via ArtemiS SUITE Recorder.
  • Rugged, compact design.
Applications
  • Sound quality analysis.
  • Troubleshooting and sound engineering.
  • Quality control and DC/AC voltage measurements.
Details
The systems feature the enhanced HEADlink 2.0 protocol, offering twice the data rate of previous versions. They are designed for flexible and affordable multi-channel analysis, with a rugged housing and silent operation. Users can select sampling rates and channel numbers based on their needs.
Performance
  • Sampling rates up to 204.8 kHz with additional HEADlab input modules.
  • Data transfer via USB 3.1 Gen. 1 or Gbit LAN.
  • Compatible with first-generation input modules (limited sampling rate).
Expandability and Networking
The systems can be expanded with additional modules and synchronized over a network using Precision Time Protocol (PTP).
Technical Data
  • Operating temperature: -10 °C to +55 °C.
  • Storage temperature: -20 °C to +70 °C.
  • Dimensions: 148 x 78 x 174 mm.
  • Weight: 1285 g (labCOMPACT12 II), 1379 g (labCOMPACT24 II).
Accessories
Includes various breakout cables, power supplies, and software modules for enhanced functionality and connectivity.
Contact Information
HEAD acoustics GmbH, Ebertstrasse 30a, 52134 Herzogenrath, Germany. Phone: +49 (0) 2407 577-0, Email: [email protected], Website: www.head-acoustics.com
Specifications
The document provides various decibel (dB) measurements, indicating precision in measurement capabilities. Linearity is specified from 0 to 100 dB below full scale for labCOMPACT12 II and labCOMPACT24 II systems.
Calibration
All measurement ranges are factory-calibrated. Additional calibration for ranges from 100 mVP to 30 VP can be performed at HEAD acoustics GmbH, accredited according to DIN EN ISO 17025.
Dynamics
The document clarifies that there is no standardized definition of "dynamics." Instead, the Signal to Noise Ratio (SNR or S/N) is provided, calculated based on the level of a sinusoidal tone with maximum modulation relative to the noise floor level across the full relevant bandwidth. The term "dynamics" is sometimes used interchangeably with S/N, but it often refers to a narrow-band calculation of inherent noise, which can result in a higher "dynamic" value depending on the analysis bandwidth.
Trademarks
ICP is a registered trademark of PCB Piezotronics Inc., and LEMO is a registered trademark of LEMO SA.
See more

Catalog excerpts

labCOMPACT12 II-1

DATA SHEET HEAD lab Compact multi-channel data acquisition systems of the second HEADfab generation with 12 (fabCOMPACT12 II) or 24 (fabCOMPACT24 II) channels for connecting analog and ICP sensors. HEAD acoustics GmbH 1 Data Sheet D31020_31021e2_ subject to change, last update: 05/24

 Open the catalog to page 1
labCOMPACT12 II-2

fabCOMPACT12 II Code 31020fabCOMPACT24 IICode 31021 /abCOMPACT12 II and /abCOMPACT24 II are compact systems that combine important functions of a second-generation HEAD/ab controller and an input module /abV12 II respectively /abV24 II for analog and ICP sensors in one device. The compact systems can be quickly and easily extended with an additional input module, as well as other compact systems and controllers. /abCOMPACT12 II provides 12, /abCOMPACT24 II 24 analog/ ICP input channels that can be used with a sampling rate of up to 51.2 kHz. Both compact systems provide a maximum sampling rate...

 Open the catalog to page 2
labCOMPACT12 II-3

DETAILS labCOMPACT12 II and labCOMPACT24 II are compact systems of the second generation and provide numerous improvements and innovations. The enhanced transmission protocol HEADlink 2.0 provides twice the data rate compared to the previous protocol and 32 bits per sample. Sample rates of up to 204.8 kHz are also possible in conjunction with secondgeneration HEADlab input modules, which can be connected additionally. Compact design High performance Compact systems combine the basic functions of a secondgeneration HEADlab controller with 12- or 24-channel input channels in single and handy devices....

 Open the catalog to page 3
labCOMPACT12 II-4

ARTIFICIAL HEADS Controllers of the second and first generation are compatible. Analog and ICP sensors can directly be connected with compact systems using breakout cables. An additional HEADlab input module for analog and ICP sensors can be connected via Single Link: HEAD acoustics GmbH 4 Data Sheet D31020_31021e2_ subject to change, last update: 05/24

 Open the catalog to page 4
labCOMPACT12 II-5

ArtemiS SUITE > Required for using ArtemiS SUITE > Configuration and control of compact systems as well as controllers, input modules, ... > HEAD Recorder is not supported ASP 801 - Basic Decoder (Code 51801) > Decoding signals: CAN FD, CAN, OBD-2, FlexRay, navigation satellite systems, RPM, resolver Additional ArtemiS SUITE software modules (APR, ASP) > Processing and analyzing measurements, ... CONNECTION OF ANALOG SENSORS / > D-Sub 25 pin ^ 12 x BNC, female, 1 m (channels 1 to 6 and 13 to 18) > D-Sub 25 pin ^ 12 x BNC, female, 1 m (channels 7 to 12 and 19 to 24) > D-Sub 25 pin ^ 12 x BNC,...

 Open the catalog to page 5
labCOMPACT12 II-6

POWER SUPPLIES FOR POWER BOXES > For labPWR I.1, labPWR I.2, labPWR I.3 Carrying case > For systems with more than 40 W and up to a maximum of 150 W HEADlab compact system for 12 analog and ICP sensors Breakout cable D-Sub 25 pin ^ Cable USB typ A ^ type C, side screw locking, 2 m Carrying case HEADlab compact system for 24 analog and ICP sensors Breakout cable D-Sub 25 pin ^ Breakout cable D-Sub 25 pin ^ Cable USB typ A ^ type C, side screw locking, 2 m Carrying case HEAD acoustics GmbH 6 Data Sheet D31020_31021e2_ subject to change, last update: 05/24

 Open the catalog to page 6
labCOMPACT12 II-7

HEAD acoustics GmbH 7 Data Sheet D31020_31021e2_ subject to change, last update: 05/24

 Open the catalog to page 7
labCOMPACT12 II-8

Number of interfaces USB specification Data rate (gross) Output voltage Output current Total output power Galvanic isolation Connector 1 x USB type C with lateral screw lock Data rate (gross) 5000 Mbit/s Number of interfaces Standard Data rate (gross) Galvanic isolation Power over Ethernet Output voltage 18 Vdc to 28 Vdc (identical to the input voltage) Maximum output power 15 W HEAD/ink version HEAD/ink 1.0, HEAD/ink 2.0 Maximum cable length 60 m Output voltage 18 Vdc to 28 Vdc (identical to the input voltage) Maximum output power 15 W Standard HEAD/ink 1.0, HEAD/ink 2.0, AES (via cable CLX...

 Open the catalog to page 8
labCOMPACT12 II-9

1 Valid for: ambient temperature 23 °C/73 °F (±3 °C/37 °F), operating duration >1 h. Vibration excitation of the device can cause deviations. HEAD acoustics GmbH 9 Data Sheet D31020_31021e2_ subject to change, last update: 05/24

 Open the catalog to page 9
labCOMPACT12 II-10

All measurement ranges receive a calibration by the factory. The measurement ranges 100 mVp to 30 Vp can additionally be calibrated in the calibration laboratory of HEAD acoustics GmbH accredited according to DIN EN ISO 17025. There is no standardized definition of „dynamics". Therefore, the Signal to Noise Ratio (SNR or S/N) value is given for the compact systems. This is calculated based on the level of a sinusoidal tone with maximum modulation in relation to the full relevant bandwidth noise floor level of the system, measured in the entire relevant frequency range. Sometimes in the literature,...

 Open the catalog to page 10

All HEAD acoustics GmbH catalogs and technical brochures

  1. HRT I

    8  Pages

  2. HRR I

    3  Pages

  3. labSAR I

    6  Pages

  4. labM6 II

    7  Pages

  5. labV8x3-Iso II

    11  Pages

  6. labV24 II

    7  Pages

  7. labV12 II

    7  Pages

  8. labVF6-Iso II

    9  Pages

  9. labVF6 II

    7  Pages

  10. BHS II

    4  Pages

  11. RC X.1

    3  Pages

  12. SQuadriga III

    26  Pages

  13. MCP I.24

    1  Page

  14. DO-160

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.