SPRINKLER FLEXIBLE DROP
4Pages

{{requestButtons}}

Catalog excerpts

SPRINKLER FLEXIBLE DROP - 1

SPRINKLER FLEXIBLE DROP TECHNICAL DATA TYPE Braided & Unbraided MAXIMUM RATED PRESSURE HYDRO TEST PRESSURE BURST PRESSURE MAXIMUM AMBIENT *Mentioned on Pages 2 of 4 TEMPERATURE END CONNECTION Inlet: 1” BSPT (M) Outlet: 1/2” or 3/4” BSPT (F) LARGEST SPRINKLER HD-UB: 5.6 K-FACTOR FOR HD-28B: 5.6 1/2” OUTLET LARGEST HD-UB: 8.0, 11.2 SPRINKLER HD-28B: 8.0, 11.2 K-FACTOR FOR 3/4” OUTLET FLEXIBILITY Limited APPROVALS ORDERING INFORMATION Size, Type of Bracket, Length of Square Bar *175 psi is only for FM Approved Flexible Drops APPLICATION Sprinkler Flexible Drop system is a ready to use assembly to fit sprinkler heads in desired location in a suspended ceiling. It easily positions the sprinkler in center of the ceiling tile at a correct height. Installation can be done in 10 to 15 minutes and does not require any special preparation. The flexible drop system is a complete unit in itself which includes a corrugated stainless steel flexible drop with nipple, reducer, square bar and brackets, which are fitted to the ceiling tile support rails to locate and secure the sprinkler in correct position. Not only does this reduce installation time but also makes the installation process a ‘mess-free’ activity by eliminating cutting and threading activities on site. The structure of threaded connection of the fitting is a limited thread (which cannot be over-tightened), and the packing seat at the Reducer and Nipple is tapered to 45°. This prevents leakage caused by damaged packing due to over tightening by an unskilled installer. Min.Bend Radius as per Technical Details These flexible drops are used in wet & dry systems for direct connection to fire sprinkler. It can be used with intermediate and heavy duty ceiling. APRIL, 2022

Open the catalog to page 1
SPRINKLER FLEXIBLE DROP - 2

TECHNICAL DETAILS FOR BRAIDED FLEXIBLE DROP : Rated Pressure psig Equivalent Length of 1 in. Schedule, 40 Steel Pipe, ft Nominal Inlet X Outlet Size, In. TECHNICAL DETAILS FOR UNBRAIDED FLEXIBLE DROP : Rated Pressure psig Nominal Inlet X Outlet Size, in. Equivalent Length of 1 in. Schedule, 40 Steel Pipe (C=120), ft

Open the catalog to page 2
SPRINKLER FLEXIBLE DROP - 3

INSTALLATION INSTRUCTIONS The HD-FLEX Sprinkler Drop is an innovative product designed to save time and cost. It can be installed fast with ease by an unskilled worker and its flexibility also allows the sprinkler drop to be installed in a limited space. The advanced technology and high quality control of HD FIRE PROTECT PVT LTD meets customer’s high standards. HD-FLEX Sprinkler Drop is designed in accordance with NFPA 13, 13D, and 13R for limited flexible application. All of anchoring components to building components for this sprinkler hose fitting are intended for use with drop ceilings,...

Open the catalog to page 3
SPRINKLER FLEXIBLE DROP - 4

HD FIRE PROTECT PVT. LTD. D. Installing Reducer to the Middle Bracket CENTRE BRACKET B-CC-B SIDE BRACKET B-ES-H (Figure 6) Open the middle bracket cover and position the Reducer inside the middle bracket properly. Close the middle bracket cover and fasten the wing bolt firmly. Recommended torque for this work is 25~30 kgf.cm (Figure 6). Every Flexible Drop is accompanied by inlet nipple, outlet reducing nipple, 700mm square bar and brackets suitable to ceiling type. Contact HD Sales for more information on type of brackets and accessories to be used. LIMITED WARRANTY HD FIRE PROTECT PVT....

Open the catalog to page 4