Introduction
The Hose Clamp Electro-Pneumatic Control Unit is designed for use with Herbie Clip and Ezyclik pneumatic tools, enhancing air pressure control. Key features include HMI touch screen control, digital air pressure and clamping time control, dry cycle detection, and batch/unit count control. It offers low maintenance and supports 1 or 2-preset program options.
Warning & Safety Instructions
Electrical: Disconnect electrical supplies before adjustments or maintenance. Observe maximum allowable electrical supply.
Compressed Air: Maximum operating pressure is 9.9 Bar with recommended airflow >50L/min. Use a 50-micron filter or better. Ensure all connections are secure before use.
Training: Only trained personnel should operate the control unit.
Weight & Noise: The unit weighs 6.7Kg, with sound pressure levels below 70dB and vibration levels below 2.5 ms-2.
Operation
Start-Up: Connect the control box to electrical and compressed air supplies, then switch on the power. Select the desired language and log in as an administrator or user.
Administrator Functions: Create new users, change passwords, and delete users through the admin screen.
User Functions: Log in, change user, and change password as needed.
Set Up
Users can set clamp time, tool pressure, and counters. The unit allows setting of time and date, and logs can be reset.
Run
Select the program number to run. Advisory fields include clamp count, batch count, dry cycles, clamp time, supply pressure, and tool pressure. Warnings such as 'Supply Pressure Too Low' are displayed if issues arise.
Reference
Includes control unit schematic, wiring diagram, and pneumatic diagram. The HMI unit orientation is adjustable for optimal positioning.
CE Marking
The control unit complies with the Machinery Directive 2006/42/EC, with applied harmonized standards including BS EN 12100:2010 and BS EN ISO 4414:2010.
Declaration of Conformity
The document is an EC Declaration of Conformity, indicating compliance with specified standards and directives, including BS EN ISO/IEC 17050-1:2010, BS EN ISO 4414:2010, BS EN 60204-1:2018, and BS EN 50565-1:2014.
Compliance and Standards
The equipment is designed to meet relevant sections of these standards and directives. The declaration is signed by David Coles, Managing Director, with technical documentation available at the specified address in Radstock, Bath, UK.
Contact Information
For any difficulties, customers are advised to contact their sales representative with samples and the serial code. Contact details for HCL in the UK, Rest of the World, and North America are provided, including phone numbers, fax numbers, and email addresses.
Additional Information
The document includes a reference to the CE Marking and the EC Declaration of Conformity in accordance with EN ISO 17050-1-2004. It also mentions the availability of a complete range of products on the HCL Fasteners website.
See more

Catalog excerpts

Hose Clamp Electro- Pneumatic Control Unit-1

Hose Clamp ElectroPneumatic Control Unit Operation, Parts & Safety Manual Original Instructions Images shown may not exactly represent the actual control box

 Open the catalog to page 1
Hose Clamp Electro- Pneumatic Control Unit-3

Index Tooling The control unit is designed to be used with the following pneumatic tools: Piston Tool Calliper Tool Calliper Tool Dry Cycle Ezyclik Calliper Tool Ezyclik Caliper Tool Dry Cycle Warning & Safety Instructions Pneumatic Tool Conrol Unit Control Unit Schematic Control Unit Wiring Diagram Control Unit Pneumatic Diagram Images shown may not exactly represent the actual control box

 Open the catalog to page 3
Hose Clamp Electro- Pneumatic Control Unit-4

Operation - Warning & Safety Instructions Read these instructions carefully: ELECTRICAL An Electrical supply represents a source of considerable potential energy. Precautions should be taken to prevent accidents. – Electrical supplies must be disconnected before any adjustments, maintenance or dismantling. – The Maximum allowable electrical supply should be observed. COMPRESSED AIR A compressed air supply represents a source of considerable potential energy. Precautions should be taken to prevent accidents. – Maximum operating pressure – 9.9 Bar – Recommended air flow into unit – >50L/min. Note....

 Open the catalog to page 4
Hose Clamp Electro- Pneumatic Control Unit-5

Operation - Pneumatic Tool Control Unit External Signal Output A 24v output signal can be supplied to the production line once the prescribed number of clamps has been tightened. Introduction Developed exclusively for the range of Herbie Clip and Ezyclik pneumatic tools, the Pneumatic Control system gives a greater level of air pressure control. Low Maintenance The Control Unit has no specific maintenance schedule and HCL Fasteners provide full backup and servicing support. Features In the drive to eliminate error from production lines the control system has a number of features including: 1...

 Open the catalog to page 5
Hose Clamp Electro- Pneumatic Control Unit-6

Touch Screen - Administrator Administrator Login Connect the Control Box to electrical and compressed air supplies. Connect the tool to the Control box. In both cases refer to the images shown in the ‘Pneumatic Tool Control unit’ section of this manual In the Start screen select ‘Login’ Switch on the power to the control box The ‘Start Up’ screen is displayed This will switch to the Main screen automatically after a short time but can be switched manually by touching the screen during this period The ‘User Login’ Screen is displayed The control box is supplied with a default Administrator level...

 Open the catalog to page 6
Hose Clamp Electro- Pneumatic Control Unit-7

Touch Screen - Administrator Administrator Login (cont) Start screen opens with the addition of an ‘Admin’ button Login as an Administrator via the front screen. See Administrator Login section When logged in as an Administrator the front screen has the option of the ‘ADMIN’ button. Select ‘Admin’ In the ‘Admin’ screen select ‘Create New User’ – OR – ‘Back’ To return to the previous screen In the ‘Admin – New User’ screen enter the name of the new user in the ‘Name’ field Enter the new users password in the ‘Password’ field Decide if the new user is a ‘User’ or if they also have ‘Admin’ authority...

 Open the catalog to page 7
Hose Clamp Electro- Pneumatic Control Unit-8

Touch Screen - Administrator ➜ In the ‘Admin’ screen select ‘Delete User’ To return to the previous page select the ‘Back’ button Change User Password ➜ In the ‘Admin – Delete User’ screen select the name of the user to be deleted in the ‘Name’ drop down menu Select ‘Delete’ – OR – ‘Back’ To return to the previous screen In the ‘Admin – Delete User’ screen a confirmation message is displayed Select ‘OK or Cancel’ – OR – ‘Back’ To return to the previous screen In the ‘Admin’ screen the ‘Command Successful’ message is displayed Select ‘Back’ To return to the previous screen In the ‘Admin’ screen...

 Open the catalog to page 8
Hose Clamp Electro- Pneumatic Control Unit-9

Touch Screen - User User Login – Equipment Switch On Change User Password (cont) Change Password box is displayed Select ‘Change Password’ – OR – Back’ To return to the previous screen In the ‘Admin – Change Password’ screen a confirmation message is displayed ‘Please Confirm Operation’ Select ‘OK or Cancel’ In the ‘Admin – Change Password’ screen the ‘Command Successful’ message is displayed Select ‘Back’ To return to the previous screen In the ‘Start’ screen Select ‘Login’ The ‘User Login’ screen is displayed Select the user form the ‘User’ drop down menu Enter the associated password Select...

 Open the catalog to page 9
Hose Clamp Electro- Pneumatic Control Unit-10

Touch Screen - User User Login – Equipment Switch On (cont) Change User ‘Command Successful’ advice message displayed on screen If incorrect login details entered ‘Command Unsuccessful’ message displayed on screen In Start screen Select ‘Change User’ The ‘User Login’ screen is displayed Select Logout Select the user from the ‘User’ drop down menu Enter the associated password Select ‘Login’ The start screen is displayed after a short t

 Open the catalog to page 10
Hose Clamp Electro- Pneumatic Control Unit-11

Touch Screen - User / Set Up ➜ Change Password (cont) ➜ The ‘Current User – Password Change’ screen is displayed Enter ‘Current Password’ Enter ‘New Password’ Enter ‘Confirm Password’ The ‘Change Password’ field is displayed Note. If the ‘Change Password’ field is not displayed there is an error with the information entered in the password fields Select ‘Change Password’ – OR – Select ‘Back’ to return to the previous screen The ‘Please confirm the operation’ message is displayed Select ‘OK’ or ‘Cancel’ In the ‘User Login’ screen the ‘Command Successful’ message is displayed Select ‘Close’ The...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.