Group: e.holding
Catalog excerpts
TANK HEATERS TANK HEATERS CONTENT VR immersion heaters with magnetic clamp 59
Open the catalog to page 2PRODUCT DESCRIPTION • Pre-heating of the medium by direct heating • Stable welded version • Easy installation • No lateral tank machining • Low minimum oil level in horizontal position • Pick up of iron particles with integrated magnetic clamps • Protection class IP 68 • Integrated thermostat with switch-off temperature +40°C (other temperatures on request) • Intergrated temperature limiter, wired for direct switching • 3 pole, 4 mtr. long cable with screwed cable gland M16 • Temperature resistant up to -20°C • Medium touched pieces made of stainless steel 1.4571 (protection tubes), brass...
Open the catalog to page 3SCREWED-IN HEATERS TANK HEATERS PRODUCT DESCRIPTION • eater for pre-heating of hydraulic oil H on mineral oil base • For horizontal mounting under oil level • Surface charge approx. 1.5 W/cm² for hydraulic oils • Bright galvanised steel cap • Material: steel (further materials on request) • Wiring schemes for various supply voltages SERIES PTHK 90 • xchangeable ceramic heating insert (mounting / E dismounting possible without oil drain) • Protection class IP 65 SERIES PTHK 92 • xchangeable ceramic heating insert (mounting / E dismounting possible without oil drain) • emperature control for...
Open the catalog to page 4SERIES WHK G 1 1/2" • Mounting via tank lid • Protection class IP 65 • Optional with temperature control TANK HEATERS *available at extra charge: 3 phases > 400 V REQUIRED DETAILS FOR QUOTATION In order to provide you a specific quotation, we need the following information: • Power • Max. immersion length • Voltage • Surface load For the calculation of the tank heater, you will find a questionnaire and selection programme in the download section of our website www.hbe-hy
Open the catalog to page 5TANK HEATERS
Open the catalog to page 6TANK HEATERS
Open the catalog to page 7TANK HEATERS
Open the catalog to page 8TUBE SCREWED-IN HEATERSDIMENSIONS STANDARD VERSION VERSION WITHTEMPERATURE CONTROL (THI) TANK HEATERS
Open the catalog to page 9TANK HEATERS OPTION • Surface charge: 1 W/cm2 • Water and water mixtures • Temperature regulation (without EDH-500) OIL PRE-HEATER EDH PRODUCT DESCRIPTION • For the pre-heating of hydraulic oil, heating oil or other hard-inflammatory agents • The fluid to be heated is lead through a heating element bundle with the aid of baffles • With pre-determined minimum flow rate a sufficient flow velocity is reached • Thus, the carbonisation temperature is avoided PRODUCT FEATURES • The mounting position is either vertically or horizontally. Vertically: Provide electrical connection on top. • Heating...
Open the catalog to page 10PERFORMANCE DATA* TANK HEATERS Flow rate [l/min] Flow rate [l/min] Flow rate [l/min] * he performance data are based on a medium intake temperature of 5°C T and are theoretically determined with the VDI heat atlas
Open the catalog to page 11OIL PRE-HEATER EDH PERFORMANCE DATA* Flow rate [l/min] Flow rate [l/min] TANK HEATERS Flow rate [l/min] * he performance data are based on a medium intake temperature of 5°C T and are theoretically determined with the VDI heat atlas
Open the catalog to page 12Flow rate [l/min] *The performance data are based on a medium intake temperature of 5°C and are theoretically determined with the VDI heat atlas.
Open the catalog to page 13TANK HEATERS "The performance data are based on a medium intake temperature of 5° C and are theoretically determined with the VDI heat atlas.
Open the catalog to page 14TANK HEATERS
Open the catalog to page 15TANK HEATERS OIL PRE-HEATER EDH HEATING TIME OF A DEFINED OIL QUANTITY The specified values are only for rough orientation. Depending on the flow rate of the pump and the installation of the system small tolerances are possible. Desired temperature increase (AT) = 20K
Open the catalog to page 16TANK HEATERS Desired temperature increase (AT) = 40K
Open the catalog to page 17HEATING POWER (kW) IN RELATION OF FLOW RATE AND DESIRED TEMPERATURE INCREASE Depending on the type of oil, small tolerances are possible. (Please consider the minimum flow rates of the selected device.) TANK HEATERS
Open the catalog to page 18TANK HEATERS
Open the catalog to page 19Online catalogue HBE GmbH Hönnestraße 47 58809 Neuenrade / Germany TÜV NORD CERT GmbH Phone +49 (0) 23 94 / 616-0 info@hbe-hydraulics.com www.hbe-hydraulics.com
Open the catalog to page 20All HBE GmbH catalogs and technical brochures
-
HBE general catalogue
198 Pages
-
air oil cooler ACI
12 Pages
-
partial flow cooler ACIP
4 Pages
-
oil tanks welded steel
14 Pages
-
oil tanks weldless steel
8 Pages
-
oil tanks casted aluminium
14 Pages
-
tank accessories
16 Pages
-
bellhousings and accessories
32 Pages
-
oil coolers
44 Pages
-
SOFTEX® couplings
20 Pages
-
STAREX® couplings
8 Pages
-
selection software
4 Pages