Temperature Control Units
19Pages

{{requestButtons}}

Catalog excerpts

Temperature Control Units - 1

HBTHERM THERMO-5 Temperature Control Units Product Catalogue 2017-10

Open the catalog to page 1
Temperature Control Units - 2

Temperature Control Units Thermo-5 Regulated mould temperatures are essential for plastics injection moulding. Temperature control units regulate mould temperatures through a liquid heat carrier by controlled inducing or dissipating of heat. Thermo-5 units provide efficient and reliable operation and are used to control temperatures in injection moulding or similar processes. …safe, reliable and low on maintenance …precise, powerful and efficient Highly accurate calibrated temperature control • ± 0,1 kelvin with self-optimizing regulation • Quality inspection certificate Short heating and...

Open the catalog to page 2
Temperature Control Units - 3

Note: Modular units do not have a proper command

Open the catalog to page 3
Temperature Control Units - 4

Additional Equipment ZL Leak stopper ZB Connection for alarm and external control ZE Connection for external sensor ZU Pump status monitor ZK Keyboard-protection ZR Clean room package ZG Mould evacuation with compressed air With automatic depression optimisation (up to 70 °C, not possible with cooler B2) Alarm using potential-free contact (rating max. 250 VAC, 4 A) Unit ON/OFF, ramp programme ON/OFF and switching nominal value 1 or 2 using potential-free contact 1 socket Harting Han 7D (male) Thermocouple type J, K, T or Pt 100 in 3-wire system, with selectable production detector 1 socket...

Open the catalog to page 4
Temperature Control Units - 5

Single units Water, direct cooling Temperature control unit Heat transfer medium Cooling Type with maximum main line temperature in °C Housing size (gp 16-18, Fig. 5) Heating (gp 14, Fig. 2) kW Eco-pump , sealless, stainless; 1,1 kW; 60 L/min, 70 m sealless, stainless; 2,8 kW; 110 L/min, 70 m stainless; 3,5 kW; 160 L/min, 70 m sealless, stainless; 3,5 kW; 160 L/min, 70 m Cooling (gp, 15, Fig. 4) 38 kW @ 60 K 110 kW @ 60 K Additional equipment Connection for alarm and external control Connection for external sensor Interface DIGITAL Interface CAN Interface OPC...

Open the catalog to page 5
Temperature Control Units - 6

Single units Water, indirect cooling Temperature control unit Heat transfer medium Cooling Type with maximum main line temperature in °C Housing size (gp 16-18, Fig. 5) Heating (gp 14, Fig. 2) kW sealless, stainless; 2,8 kW; 110 L/min, 70 m stainless; 3,5 kW; 160 L/min, 70 m sealless, stainless; 3,5 kW; 160 L/min, 70 m Cooling (gp, 15, Fig. 4) 30 kW @ 60 K 50 kW @ 60 K 90 kW @ 60 K Additional equipment Leak stopper Connection for alarm and external control Connection for external sensor Interface DIGITAL Interface CAN Interface OPC UA Interface PROFIBUS-DP Pump status...

Open the catalog to page 6
Temperature Control Units - 7

Single units Water, indirect cooling Temperature control unit Heat transfer medium Cooling Type with maximum main line temperature in °C Housing size (gr 16—18, Fig. 5) Eco-pump ik , sealless, stainless; 1,1 kW; 60 L/min, 70 m sealless, stainless; 2,8 kW; 110 L/min, 70 m stainless; 3,5 kW; 160 L/min, 70 m sealless, stainless; 3,5 kW; 160 L/min, 70 m Additional equipment Leak stopper Connection for alarm and external control Connection for external sensor Interface DIGITAL Interface CAN Interface ORC UA Interface RROFIBUS-DR Rump status monitor Keyboard-protection Clean room...

Open the catalog to page 7
Temperature Control Units - 8

Single units Water, indirect cooling Temperature control unit Heat transfer medium Cooling Type with maximum main line temperature in °C Housing size (gr 16—18, Fig. 5) Heating (gp. 14, Fig. 2) kW Pump sealless, stainless; 0,5 kW; 30 L/min, 52 m (gp 14, Fig. 3) sealless, stainless; 1,0 kW; 50 L/min, 70 m Eco-pump ik , sealless, stainless; 1,1 kW; 60 L/min, 70 m sealless, stainless; 2,8 kW; 110 L/min, 70 m sealless, stainless; 3,5 kW; 160 L/min, 70 m Cooling (gr 15, Fig. 4) 30 kW @ 60 K 50 kW @ 60 K 90 kW @ 60 K Additional equipment Leak stopper Connection for alarm and...

Open the catalog to page 8
Temperature Control Units - 9

Single units Water, indirect cooling Temperature control unit Heat transfer medium Cooling with maximum main line temperature in °C Type Housing size (gP. 17/18, Fig. 5) kW Heating (gP. 14, Fig. 2) sealless, stainless; 0,5 kW; 30 L/min, 52 m sealless, stainless; 1,0 kW; 50 L/min, 70 m (gP. 14, Fig. 3) Eco-pump , sealless, stainless; 1,1 kW; 60 L/min, 70 m sealless, stainless; 2,8 kW; 110 L/min, 70 m sealless, stainless; 3,5 kW; 160 L/min, 70 m 30 kW @ 60 K Cooling (gP. 15, Fig. 4) 50 kW @ 60 K 90 kW @ 60 K Additional equipment Connection for alarm and external control Connection for...

Open the catalog to page 9
Temperature Control Units - 10

Single units Water, indirect cooling Temperature control unit Heat transfer medium Cooling with maximum main line temperature in °C Type Housing size (gP. 18, Fig. 5) kW Heating (gP. 14, Fig. 2) sealless, stainless; 0,5 kW; 30 L/min, 52 m Pump sealless, stainless; 1,0 kW; 50 L/min, 70 m (gP. 14, Fig. 3) Eco-pump , sealless, stainless; 1,1 kW; 60 L/min, 70 m 30 kW @ 60 K Cooling (gP. 15, Fig. 4) 50 kW @ 60 K Additional equipment Connection for alarm and external control Connection for external sensor Interface DIGITAL Interface CAN Interface OPC UA Interface PROFIBUS-DP Pump status monitor...

Open the catalog to page 10
Temperature Control Units - 11

Single units Oil, indirect cooling Temperature control unit Heat transfer medium Cooling Type with maximum main line temperature in °C Housing size (gr 17/18, Fig. 5) Heating (gp. 14, Fig. 2) kW Pump sealless, stainless; 0,5 kW; 30 L/min, 52 m (gp 14, Fig. 3) sealless, stainless; 1,0 kW; 50 L/min, 70 m Connection for alarm and external control Connection for external sensor Interface DIGITAL Interface CAN Interface ORC UA Interface RROFIBUS-DR Rump status monitor Keyboard-protection Ordering example: HB-250T3-8-2M-A3-ZE-ZD-ZU, 405, Eng lish • Standard specification O...

Open the catalog to page 11
Temperature Control Units - 12

Communication (Fig. 1) Basic circuit diagram □ Command 1) Command deactivated

Open the catalog to page 12
Temperature Control Units - 13

Heating Capacity, Electricity Supply (Fig. 2) The heating capacity applies at rated voltage (400 V, 460 V or 210 V) and varies max. ±10 % within the range indicated. Maximum fusing; Cross-section through unit mains cable (with mains voltage) Heating 400 V or 460 V 8 kW 3x20 A; 2,5 mm2 16 kW 3x32 A; 6 mm2 32 kW 3x63 A; 16 mm2 Pump Capacity Curve (Fig. 3) Fixed speed pumps Pump head H m Flow rate L/min Flow rate L/min Attainable practical values Attainable practical values with housing size 3 Variable speed Eco-pump Pump head H m 70 In Eco-mode the unit will control the speed depending on...

Open the catalog to page 13