Overview: The Vario-5 Switching Unit is engineered for variothermal control in injection moulding, enhancing part quality and reducing cycle times by alternating between high and low temperatures during injection and cooling phases.
Specifications: The system integrates with two Thermo-5 units, utilizing a fluid-fluid technique for temperature switching. It is compatible with existing moulds that have appropriate temperature control channels and can be operated centrally via Thermo-5 or Panel-5.
Features: The Vario-5 is cost-effective, supports multiple uses, and integrates seamlessly with existing systems. It includes intelligent wizards for temperature and time settings, USB data recording, and Excel analysis. Its compact, clean, and quiet design is ideal for clean room environments.
Performance: The unit improves part quality by eliminating weld lines, enhancing contour accuracy, and reducing sink marks. It offers precise process management with monitored switching and an integrated energy buffer, minimizing heating and cooling power requirements.
Safety and Maintenance: The Vario-5 features automated process monitoring, durable non-corroding materials, and a closed system to prevent steam and corrosion. It operates without pressure shocks and requires minimal maintenance.
Technical Specifications: Compatible with various power supplies and communication interfaces like CAN and OPC UA, the unit works with Thermo-5 units for both hot and cold circuits, with specific safety valve and manometer recommendations.
Recommendations: For optimal performance, temperature control channels should be near the cavity surface, and variothermal areas should be isolated. High thermal conductivity materials, such as copper alloys, are recommended for critical areas.
Company Background: HB-Therm AG, a Swiss-based leader in temperature control units since 1967, emphasizes Swiss-made quality and is ISO 9001/14001 certified. The company has a global presence with subsidiaries and agencies worldwide.
Customer Service: HB-Therm provides expert advice on temperature control processes, product specifications, connections, data interfaces, heat transfer mediums, and equipment servicing. Support is available for specialist requirements, equipment operation, and staff training.
Specifications: Specifications may change without notice, reflecting a dynamic approach to product development.
Contact Information: HB-Therm AG is headquartered in St. Gallen, Switzerland, with subsidiaries in Germany and France. Contact details include phone numbers and email addresses.
Global Presence: HB-Therm has distributors in numerous countries, including Australia, Austria, Belgium, Brazil, China, and many others, ensuring a wide-reaching global network.
See more

Catalog excerpts

Switching Unit Vario-5-1

Switching Unit for Variothermal Control Product Catalogue 2019-10

 Open the catalog to page 1
Switching Unit Vario-5-2

Switching Unit Vario-5 Special challenges in injection moulding cannot be overcome with classical mould temperature control. The solution is a variothermal control: High temperature during injection, cold temperature in the cooling phase. Together with two temperature control units Thermo-5, the Vario-5 forms a variothermal system according to the fluid-fluid technique. Alternatingly, it links either the hot or the cold unit to the same circuit. It is quite possible to use existing moulds if the temperature control channels are suitably arranged. Vario-5 provides easy and quiet operation. It...

 Open the catalog to page 2
Switching Unit Vario-5-3

Standard Equipment Hydraulics Closed hydraulic system without oxygen contact Energy buffer 9 Maintenance-free, pressure shock-free Hydraulic circuit made of non-corroding materials Functions Wizards determine setpoint temperatures, reaction times and switching times Monitoring / Safety Monitoring of the switching procedures Automatic limit value settings for temperatures and flow Electrically operated valves (no compressed air) Lockable and abrasion resistant castors (PUR) Fibre-free insulation Command / Display Large choice of display windows and values Storage of specific variothermal parameters...

 Open the catalog to page 3
Switching Unit Vario-5-4

Technical Specifications • Standard specification o Optional 1) Recommended for mould circuits of 0,9 L and larger 2) For detailed information and other lenghts g Accessories program (D8064-EN) Recommendation for Unit Type Thermo-5 Hot water circuit Thermo-5, HB-160 or HB-180, pump 4M, heating and cooling power depends on application Cold water circuit Thermo-5, HB-140, pump 4M, heating and cooling power depends on application If the unit for the hot water circuit runs over 160 °C, the unit for the cold water circuit must be equipped with a 17 bar safety valve and a manometer 25 bar (not possible...

 Open the catalog to page 4
Switching Unit Vario-5-5

□ Command 1) Command deactivated

 Open the catalog to page 5
Switching Unit Vario-5-6

General Technical Data Power supply Mains voltage Mains cable to unit Temperature Environment Humidity Cover Colour Access cover Protection class Standards Certification/Approval Resolution Temperature measurement Tolerance 100–240 V, 50/60 Hz LNPE, 4 m (plug on request) 5–40 °C 35–85 % RH (non-condensing) RAL 7035 (glossy light grey), RAL 5012 (glossy light blue) RAL 7021 (glossy black grey) IP 44 EN 50581, EN 61000-6-2, EN 61000-6-4, EN 60204-1, EN ISO 13732-1, EN ISO 12100 CE (compliance with relevant CE directives) 0,1 °C ±3 K Input hot water circuit Output hot water circuit OUT C Output...

 Open the catalog to page 6
Switching Unit Vario-5-7

In injection moulding some typical problems cannot be solved by traditional temperature control: • visible weld lines in optically critical areas. • incomplete moulding of the finest structures and lacking contour accuracy (e.g. for optical lenses, micro- or nanostructures, piano lacquer) • insufficient surface quality of foamed and fibre-reinforced parts • excessively high injection pressures for extremely small cross-sections • sink marks at extreme wall thickness ratios Reasons: In injection moulding the hot plastic melt meets a relatively cool mould surface in the injection phase. The latter...

 Open the catalog to page 7
Switching Unit Vario-5-8

The Process The fluid-fluid technique sends alternatingly hot and cold temperature control medium through the temperature control channel immediately below the cavity surface, controlled by the machine cycle. The temperatures are set on the two temperature control units. If there is a temperature sensor available at a suitable position in the mould, the switch-over or the start of injection can also be made depending on the mould temperature to increase process reliability. Thermo-5 Cold water circuit Operating mode: Heating Thermo-5 Cold water circuit Operating mode: Cooling Control Cyclic heating...

 Open the catalog to page 8
Switching Unit Vario-5-9

Frame Conditions In variothermal control the temperature at the surface of the cavity will be actively changed within the injection cycle. The area around the cavity is thus cyclically heated and cooled. Depending on the configuration of the temperature control channels the temperature at the surface of the cavity reacts stronger or weaker and the area is larger or smaller. To efficiently achieve the largest temperature gradients possible the following is recommended: Distance of the temperature control channel from the surface of the cavity Variothermal mass Isolation Connections Temperature...

 Open the catalog to page 9
Switching Unit Vario-5-10

HB-Therm worldwide. HB-Therm is one of the leading manufacturers of temperature control units worldwide. Since 1967 HB-Therm AG has been developing and producing innovative temperature control technology to the highest quality standards. With its comprehensive know-how and motivated workforce, the company has succeeded in becoming the technology leader in its sector. This Swiss family enterprise employs around 150 staff and has established itself as a systems supplier offering seamless customer support from machine design through to a complete after-sales service. Production is exclusively in...

 Open the catalog to page 10
Switching Unit Vario-5-11

HB-THERM AG Spinnereistrasse 10 (WU 3) Postfach 9006 St. Gallen Switzerland Phone +41 71 243 6-530 [email protected], www.hb-therm.ch Subsidiaries HB-THERM GmbH DammstraUe 78 53721 Siegburg Germany Phone +49 2241 5946-0 [email protected], www.hb-therm.de HB-THERM S.A.S. 5378 Route du Pou du Ciel ZI de Reyrieux 01600 Reyrieux France Phone +33 4 74 00 43 30 [email protected], www.hb-therm.fr Distributors Australia (AU) Comtec Australia Pty Ltd, Keysborough VIC 3173 Austria (AT) Luger Gesellschaft mbH, 3011 Purkersdorf Belgium (BE) AJ Solutions BVBA, 2240 Zandhoven Brazil (BR) HDB Comercio e...

 Open the catalog to page 11
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.