Cartridge Filter

Cartridge Filter

Cartridge Filter

Product catalog summary
Introduction: This document provides detailed instructions for the installation, operation, and maintenance of Hayward cartridge filters. It emphasizes the importance of following guidelines to prevent injury and equipment damage.
Guarantee and Responsibility: Hayward guarantees its products against defects in material and workmanship but does not assume responsibility for damages due to improper installation or chemical incompatibility. Users should verify compatibility and adhere to operating pressure and temperature limits.
Installation Instructions:
  • Inspection: Inspect the filter vessel upon receipt for any transit damage.
  • Location and Support: Install the filter vessel at least 24 inches downstream of a Hayward strainer and bolt it to the floor.
  • Piping Installation: Use plastic piping upstream and downstream of the filter vessel. Connect a 2-inch line from the strainer to the filter inlet and from the filter outlet to the system pump suction. Install a vent fitting with an O-ring and secure it with a hose clamp.
  • Threaded and Flanged Connections: Follow specific guidelines for wrapping threads with Teflon tape and tightening flange bolts to ensure leak-proof joints.
Operation: The filter vessel is part of the Hayward filtration system, concentrating solids in disposable cartridges. Follow the startup procedure to ensure proper operation and monitor pressure differential to determine when cartridge replacement is necessary.
Cartridge Replacement: Steps include closing valves, draining the filter, removing the cover, and replacing the cartridge. Ensure the system is depressurized before disassembly.
Specifications:
  • Maximum Working Pressure: 150 PSIG at 70°F
  • Inlet/Outlet/Drain: 2-inch NPT
  • Maximum Flow: 100 GPM without cartridge
  • Vent: 3/8-inch male tube fitting
  • Seals: VITON; EPDM optional
Installation of CFXKITV: Instructions for installing the cartridge vessel conversion kit, including O-ring placement and flow diffuser installation.
See more

Catalog excerpts

Cartridge Filter-1

1. Hayward guarantees its products against defective material and workmanship only. Hayward assumes no responsibility for damage or injuries resulting from improper installation, misapplication, or abuse of any product. 2. Hayward assumes no responsibility for damage or injury resulting from chemical incompatibility between its products and the process fluids to which they are subjected. Compatibility charts provided in Hayward literature are based on ambient temperatures of 70F and are for reference only. Customer should always test to determine application suitability. 3. Consult Hayward literature to determine operating pressure and temperature limitations before installing any Hayward product. Note that the maximum recommended fluid velocity through any Hayward product is eight feet per second. Higher flow rates can result in possible damage due to the water hammer effect. Also note that maximum operating pressure is dependent upon material selection as well as operating temperature. 4. Hayward products are designed primarily for use with non-compressible liquids. They should NEVER be used or tested with compressible fluids such as compressed air or nitrogen. 5. Systems should always be depressurized and drained prior to installing or maintaining Hayward products. 6. Temperature effect on piping systems should always be considered when the systems are initially designed. Piping systems must be designed and supported to prevent excess mechanical loading on Hayward equipment due to system misalignment, weight, shock, vibration, and the effects of thermal expansion and contraction. 7. Because PVC and CPVC plastic products become brittle below 40F, Hayward recommends caution in their installation and use below this temperature. 8. Published operating torque requirements are based upon testing of new valves using clean water at 70F. Valve torque is affected by many factors including fluid chemistry, viscosity, flow rate, and temperature. These should be considered when sizing electric or pneumatic actuators. 9. Due to differential thermal expansion rates between metal and plastic, transmittal of pipe vibration, and pipe loading forces DIRECT INSTALLATION OF METAL PIPE INTO PLASTIC CONNECTIONS IS NOT RECOMMENDED. Wherever installation of plastic valves into metal piping systems is necessary, it is recommended that at least 10 pipe diameter in length of plastic pipe be installed upstream and downstream of the plastic valve to compensate for the factors mentioned above. > Upon receipt of the filter vessel, inspect it for damage that might have occurred during transit. Report any damage to the carrier immediately. > The Hayward filter vessel should be installed not less than 24 down stream of a Hayward strainer. The filter vessel must be bolted to the floor to insure proper piping installation. A integral flange on the base of the g filter vessel will accept 3/4Ԕ studs. > DO NOT FORGET THE O-RING. For installation in metal piping systems it is recommended that the Hayward flanged version CFLT4202F or CFLT4201F be installed. Plastic piping is still required. From the Hayward strainer, a 2 line is required to the inlet of the filter vessel. Connect 2Ԕ line to a valve and then to the upper 2 NPTF (inlet) of the filter vessel. A 2Ԕ line must be piped from the filter vessel 2 NPTF bottom port (outlet) to a determined suction source (system pump suction). A 2Ԕ valve such as a Hayward Diaphragm or Butterfly valve is required on this outlet line. It is recommended that a 2 drain valve be installed on the unused bottom 2Ԕ NPT port The vent fitting must be installed on the top of the unit. A 3/8 ID tube should be attached over the barb and secured with a hose clamp on the vent fitting. This hose will be used to direct the flow from the vent fitting. The top of the vent fitting is normally plugged. This plug can be removed and replaced with a pressure gauge that measures inlet pressure to the bag filter. It is recommended that a gauge guard be installed between the filter vent and the gauge. > Threaded end connections are manufactured to ASTM specifications D2464-88. F437-88 and ANSI B2.1. Wrap threads of pipe with Teflon tape of 3 to 3-1/2 mil thickness. The tape should be wrapped in a clockwise direction starting at the first or second full thread. Overlap each wrap by, 1/2 the width of the tape. The wrap should be applied with sufficient tension to allow the threads of a single wrapped area to show through without cutting the tape. The wrap should continue for the full effective length of the thread. Pipe sizes 2Ԕ and greater will not benefit with more than a second wrap, due to the greater thread depth. To provide a leak proof joint, the pipe should be threaded into the end connection hand tightӔ. Using a strap wrench only . (Never use a stillson type wrench) tighten the joint an additional 1/2 to 1-1/2 turns past hand tight. Tightening beyond this point may induce excessive stress that could cause failure. > RECOMMENDED FLANGE BOLT TORQUE Flange bolts should be tight enough to slightly compress the gasket and make a good seal, without distorting or putting excessive stress on the flanges. Suitable washers should be used between the bolt head and flange and the nut and flange. Bolts should be tightened in alternating sequence. > FLANGE SIZE BOLT DIAMETER. TORQUE FT. LBS. 2 5/8 15-25 >

 Open the catalog to page 1
Cartridge Filter-2

The Hayward polypropylene filter vessel is designed as an integral part of the Hayward filtration system. Installed down stream of the Hayward strainer, the Hayward filter concentrates the solids, and provides convenient, economical removal of the solids from the process with very low liquid loss. Large solids are separated from the liquid with the Hayward strainer while smaller solids are accumulated in the cartridge filter. The cartridge filter concentrates the solids in disposable cartridges, while clean liquid is piped back to the process. > Follow the procedure below for replacing the cartridge...

 Open the catalog to page 2