Bottle filler model 1920W
7Pages

{{requestButtons}}

Catalog excerpts

Bottle filler model 1920W - 1

Bottle filler PUSH BUTTON With its patented stainless steel, push-button activated valve assembly which allows for front access stream adjustment as well as cartridge and strainer access, this bottle filler offers 100% lead free waterways. The valve works at an operating pressure range of 30 to 90 psi (2.1 to 6.2 bar). LAMINAR FLOW Adjustable, splash-free, 1 gpm (3.78 L) laminar water flow. EFFICIENT & FLEXIBLE INSTALLATION Unit is designed for retrofit or new construction applications. No drain required for mounting over existing drinking fountain. DURABLE BUILD Good for indoor or outdoor applications (in non-freezing areas). Made with 100% Stainless Steel for vandal resistance. MOUNTING OPTIONS Select from mounting plate and back panel models to complete installation. Unit can mount on various wall types. CONSTRUCTION Unit is made of 14 gauge Type 304 stainless steel with a white painted finish that resists stains and corrosion, and has soft rounded corners. Unit features vandal-resistant bottom plate and dispensing nozzle. Model 1920W wall mounted bottle filler shall include 100% lead-free waterways, gloss white finish, stainless steel construction, 1 gpm (3.78 L) laminar flow, push-button operated stainless steel valve with front-accessible cartridge and flow adjustment. It can be used as a stand-alone station, or mounted above the Haws® 1311 and 1501 drinking fountain models. APPLICATIONS □ Mounting Plate: Model 6700 universal mounting plate for most wall mounted fountains. Priced Separately. □ Mounting Plate: Model 6700.4 "Hi-Lo" universal mounting plate for most dual bubbler fountains. Priced Separately □ Mounting Plate: Model 6700.4L mounting plate for positioning model 1920 over low side of dual drinking fountains. For more information, visit www.hawsco.com or call (888) 640-4297. This type of wall mounted bottle filler may be placed in settings such as schools and other locations in and around office buildings, or with existing fountain installations where the temperature remains above freezing. Haws® manufactures drinking fountains and electric water coolers to be lead-free by all known definitions including NSF/ANSI 61, Section 9, NSF/ANSI 372, California Proposition 65, and the Federal Safe Drinking Water Act. Product is compliant to California Health and Safety Code 116875 (AB 1953-2006). 1455 Kleppe Lane :: Sparks, NV 89431 :: p. 775.359.4712 :: f. 775.359.7424 :: e. info@hawsco.com :: www.hawsco.com :: 02 January, 2019 DISCLAIMER: Continued product improvements make specifications subject to change without notice. Check www.hawsco.com for the latest product information and updates.

Open the catalog to page 1
Bottle filler model 1920W - 2

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. 1 . SEE SEPARATE INSTALLATION DRAWINGS FOR MOUNTING PLATES AND BACKPANELS 2. WHEN INSTALLING THIS UNIT, LOCAL, STATE OR FEDERAL CODES SHOULD BE ADHERED TO FOR INSTALLATION LOCATIONS, WASTE & SUPPLY REQUIREMENTS OTHER THAN SHOWN. 1455 KLEPPE LANE SPARKS, NEVADA 89431 (775) 359-4712 FAX (775) 359-7424 E-MAIL: HAWS@HAWSCO.COM WEBSITE: WWW.HAWSCO.COM MODEL 1920/1920HPS/1920W PART NUMBER SCALE: N/A | DRAWING TYPE: ©2017 Haws...

Open the catalog to page 2
Bottle filler model 1920W - 3

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. 6700 MOUNTING PLATE (BEHIND FINISH WALL) - OR 6700R RETROFIT PLATE (ON TOP OF FINISH WALL) 6700.4L MOUNTING PLATE (BEHIND FINISH WALL) - OR 6700R RETROFIT PLATE (ON TOP OF FINISH WALL) (IF FOUNTAIN HIGH/LOW SIDES ARE REVERSED USE BP32R) INSTALLATION ABOVE HAWS 1001, 1001HPS, 1001HPSMS, 1001MS, H1001.8, H1001.8HPS 3/8" PUSH IN TEE (CONNECT TO FOUNTAIN SUPPLY) * IF YOUR FOUNTAIN IS THIS STYLE USE THESE DIMENSIONS 1. SEE SEPARATE...

Open the catalog to page 3
Bottle filler model 1920W - 4

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. 6700.4L MOUNTING PLATE (BEHIND FINISH WALL) - OR 6700R RETROFIT PLATE (ON TOP OF FINISH WALL) (IF FOUNTAIN HIGH/LOW SIDES ARE REVERSED USE BP32R) INSTALLATION ABOVE HAWS 1119, 1119.14, H1119.8 6700 MOUNTING PLATE (BEHIND FINISH WALL) - OR 6700R RETROFIT PLATE (ON TOP OF FINISH WALL) INSTALLATION ABOVE HAWS 1109, 1109.14, H1109.8 3/8" PUSH IN TEE (CONNECT TO FOUNTAIN SUPPLY) * IF YOUR FOUNTAIN IS THIS STYLE USE THESE DIMENSIONS 1. SEE...

Open the catalog to page 4
Bottle filler model 1920W - 5

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. 6700 MOUNTING PLATE (BEHIND FINISH WALL) - OR 6700R RETROFIT PLATE (ON TOP OF FINISH WALL) 6700.4L MOUNTING PLATE (BEHIND FINISH WALL) - OR 6700R RETROFIT PLATE (ON TOP OF FINISH WALL) (IF FOUNTAIN HIGH/LOW SIDES ARE REVERSED USE BP32R) INSTALLATION ABOVE HAWS 1117L, H1117.8 INSTALLATION ABOVE HAWS 1107L, H1107.8 3/8" PUSH IN TEE (CONNECT TO FOUNTAIN SUPPLY) * IF YOUR FOUNTAIN IS THIS STYLE USE THESE DIMENSIONS 1. SEE SEPARATE...

Open the catalog to page 5
Bottle filler model 1920W - 6

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. 6700 MOUNTING PLATE (BEHIND FINISH WALL) - OR BOLT 1920 ON TO EXISTING WALL 6700.4L MOUNTING PLATE (BEHIND FINISH WALL) - OR 6700R RETROFIT PLATE (ON TOP OF FINISH WALL) (IF FOUNTAIN HIGH/LOW SIDES ARE REVERSED USE BP32RW) INSTALLATION ABOVE HAWS 1501 INSTALLATION ABOVE HAWS 1311 3/8" PUSH IN TEE (CONNECT TO FOUNTAIN SUPPLY) * IF YOUR FOUNTAIN IS THIS STYLE USE THESE DIMENSIONS 1. SEE SEPERATE INSTALLATION DRAWINGS FOR MOUNTING...

Open the catalog to page 6
Bottle filler model 1920W - 7

THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE. 6700 MOUNTING PLATE (BEHIND FINISH WALL) - OR BOLT 1920 ON TO EXISTING WALL INSTALLATION ABOVE HAWS 1047 * IF YOUR FOUNTAIN IS THIS STYLE USE THESE DIMENSIONS 3/8" PUSH IN TEE (CONNECT TO FOUNTAIN SUPPLY) 1. SEE SEPERATE INSTALLATION DRAWINGS FOR MOUNTING PLATES AND BACKPANELS 2. WHEN INSTALLING THIS UNIT, LOCAL, STATE OR FEDERAL CODES SHOULD BE ADHERED TO FOR INSTALLATION LOCATIONS, WASTE & SUPPLY REQUIREMENTS OTHER THAN SHOWN. C...

Open the catalog to page 7

All Haws Corporation catalogs and technical brochures