Catalog excerpts
A QUALITY COMPANY ALWAYS DEMANDS THE BEST > For those who demand quality, reliability and above all, safety, Hawke products are the obvious choice. Smarter Products > Hawke International is a member of the worldwide Hubbell Group of Companies and is a well established leading manufacturer of electrical equipment for Hazardous (Classified) locations and hostile environments, with an innovative range of cable connection, termination and barrier products.Sustained safety and reliability under extreme conditions are Hawke'sprimary goals. The company also promise ease of installation and low...
Open the catalog to page 34 - 7 9 - 23 Page No. Cable Gland Features 10501/421 Technical Data 11501/423 Technical Data 12501/453/Universal Technical Data 13501/453/RAC Technical Data 14501/453/RAC/L Technical Data PSG 553/RAC Technical Data ICG 623 Technical Data 17ICG 653/Universal Technical Data 18ICG 653/Universal/L Technical Data 19501/414 Technical Data 20SB 474 Technical Data 21CSB 656 Technical Data 22Oversize Cable Glands 23Cable Gland Features 26121 Technical Data 27 123 Technical Data 28150/RAC Technical Data 151/RAC Technical Data 30153/RAC Technical Data 31153/RAC/L Technical Data 32114 Technical Data >...
Open the catalog to page 435 - 42 Page No. Cable Gland /Connectors Features 36710 Technical Data 37711 and 713 Technical Data 38753 Technical Data 755 Technical Data 40153 > /X Technical Data 41701 Technical Data 42Nylon, Red Fibre and Serrated Washers 44Earth Tags and Locknuts 45 Shrouds and Insulated Adaptors 46Stopping Plugs 47Adaptors and Reducers 48 43 - 48 > Hawke Cable Glands Contents 49 - 79 1.0 Potentially Explosive Atmospheres2.0 Area Classification (Classification of Locations) 3.0 CENELEC and IEC 4.0 ATEX 94/9/EC Directive505050 - 545.0 Wiring Systems and Extract from EN 60079-14 : 1997/IEC 60079-14 :...
Open the catalog to page 5Hawke Cable Glands
Open the catalog to page 10Hazardous Area Cable Glands
Open the catalog to page 11Hazardous Area Cable Glands This arrangement offers IP66, IP67, IP68 (30 metres for 7 days), NEMA 4X and Deluge (DTS01) Ingress Protection. The seal is manufactured from a silicone material, has LSFZH properties, is ozone and oil resistant and is suitable for use at both high and low temperatures. The Rear Sealing System covers the entire range of cable diameters without the need for special seals and the cable acceptance range is stamped on the backnut for ease of inspection. The backnut can be hand tightened, with only one further spanner turn required to ensure IP66, IP67, IP68 and NEMA...
Open the catalog to page 12'B' Assembly instruction data sheet No. A.I. 307. For sizes O s to J. Baseefa Certificate No. BAS 01 ATEX 2266X. Assembly instruction data sheet No. A.I. 308. For sizes Os to F. No. A.I. 335. For sizes G to J. Baseefa Certificate No. BAS 01 ATEX 2268X. Assembly instruction data sheet No. A.I. 302. For sizes Os to F. No. A.I. 329. For sizes G to J. Baseefa Certificate No. BAS 01 ATEX 2267X. > Entry Thread For application, features, technical data, general information, materials/finishes and cable gland ordering examples, please refer to :- Page 11 (501/421). For application, features,...
Open the catalog to page 26Industrial Cable Glands
Open the catalog to page 27Cable Glands Industrial > Industrial Industrial Cable Glands Features > Unique Rear Sealing System Inspectable Deluge Seal The Original Reversible Armour Clamp This arrangement offers IP66, IP67, IP68 (30 metres for 7 days), NEMA 4X and Deluge (DTS01) Ingress Protection. The seal is manufactured from a silicone material, has LSFZH properties, is ozone and oil resistant and is suitable for use at both high and low temperatures. The Rear Sealing System covers the entire range of cable diameters without the need for special seals and the cable acceptance range is stamped on the backnut for...
Open the catalog to page 28Hawke Cable Glands
Open the catalog to page 36North American Series Cable Glands/Connectors
Open the catalog to page 37North American SeriesCable Glands/Connectors This arrangement offers IP66, IP67, IP68 (30 metres for 7 days), NEMA 4X and Deluge (DTS01) Ingress Protection. The seal is manufactured from a silicone material, has LSFZH properties, is ozone and oil resistant and is suitable for use at both high and low temperatures. The Rear Sealing System covers the entire range of cable diameters without the need for special seals and the cable acceptance range is stamped on the backnut for ease of inspection. The backnut can be hand tightened, with only one further spanner turn required to ensure IP66,...
Open the catalog to page 38Technical Data
Open the catalog to page 51The intent of this section of the catalogue is to identify important features that may be useful in the selection and installation of explosion protected electrical equipment. Of flammable substances in the form of gases, vapours, mists, dusts or fibresIn which, after ignition has occurred, combustion spreads to the entire unburned mixtureUnder atmospheric conditionsWith airAn explosive atmosphere is defined as a mixture: - There are numerous different regulations, codes, guidelines and standards for the design, installation and maintenance of electrical and non-electrical systems for use...
Open the catalog to page 52An area in which combustible dust, as a cloud, is present continuously or frequently, during normal operation, in sufficient quantity to be capable of producing an explosive concentration of combustible dust in a mixture with airAn area, in which combustible dust, as a cloud, is occasionally present during normal operation, in a sufficient quantity to be capable of producing an explosive concentration of combustible dust in a mixture with air.An area, in which combustible dust, as a cloud, may occur infrequently and persist for only a short period, or in which accumulations of layers of...
Open the catalog to page 53The grouping of gases and vapours are classified into Group I and Group II categories.Group I is relevant to atmospheres containing firedamp (a mixture of gases, composed mostly of methane, found underground in mines).Group II is intended for use in all other places with potentially explosive atmospheres. Group II electrical apparatus with types of protection 'd' and 'i' are further sub-divided into apparatus group IIA, IIB or IIC. Electrical apparatus with type of protection 'n' may also be sub-divided if it contains certain devices or components. There are numerous different regulations,...
Open the catalog to page 55All Hawke International U.K catalogs and technical brochures
-
501/RCG
2 Pages
-
Hazcon Control Stations Overview
24 Pages
-
Terminal Block Type HTB6
2 Pages
-
EJB Series Enclosures
1 Pages
-
495 (M to M) 90° Fixed Elbow
1 Pages
-
491 In-Line Swivel Union
1 Pages
-
481 (M to F) Union
1 Pages
-
489 Breather Drain
1 Pages
-
321/R Cable Gland
1 Pages
-
453/T Cable Gland
1 Pages
-
PL630
1 Pages
-
PL626
1 Pages
-
PL620
1 Pages
-
PL615
1 Pages
-
PL612
1 Pages
-
321/R
1 Pages
-
321
1 Pages
-
114
1 Pages
-
151/RAC
1 Pages
-
150/RAC
1 Pages
-
153/RAC
1 Pages
-
153/UNIVERSAL
1 Pages
-
123
1 Pages
-
121
1 Pages
-
701
1 Pages
-
153/X
1 Pages
-
755
1 Pages
-
753
1 Pages
-
711
1 Pages
-
710
1 Pages
-
653/T
1 Pages
-
653/UNIVERSAL
1 Pages
-
623
1 Pages
-
453/T
1 Pages
-
453/UNIVERSAL
1 Pages
-
453/RAC
1 Pages
-
ICG 653/UNIV/L
1 Pages
-
PSG 553/RAC
1 Pages
-
501/453/UNIV
1 Pages
-
501/453/RAC/L
1 Pages
-
501/453/RAC
1 Pages
-
HB Type
1 Pages
-
SK-Series
4 Pages
-
EJB Series
1 Pages
-
SB 474 Cable glands
1 Pages
-
S Series Enclosures
1 Pages
-
Power Ex Features
2 Pages
-
PL Series GRP Enclosures
1 Pages
-
Instrum Ex Features
2 Pages
-
ICG 623 Cable glands
1 Pages
-
EZE Series Enclosures
1 Pages
-
CSB 656 N Cable glands
1 Pages
-
Control Ex Features
2 Pages
-
753 Cable glands
1 Pages
-
711 Cable glands
1 Pages
-
501/423 Cable glands
1 Pages
-
321 Cable glands
1 Pages
-
153 Cable glands
1 Pages
-
151 RAC Cable glands
1 Pages
-
123 Cable glands
1 Pages
-
114 Cable glands
1 Pages
-
501/421 Cable Gland
1 Pages
-
501/414 Cable Gland
1 Pages
Archived catalogs
-
Cable Gland Shortform
12 Pages
-
EExe and EExd Enclosures
75 Pages
-
Connection Products
12 Pages
-
Ex Connectors
8 Pages