
Flameproof, Increased Safety, Dust Protection Class - Zones - Divisions Certified ATEX / IECEx Application Outdoor or indoor use. For use with single wire armour ‘W’, wire braid ‘X’, steel tape armour ‘Z’, elastomer and plastic insulated cables. For particular use with:- Cables that are not effectively filled, compact and/or circular, have tape bedding or have hygroscopic fillers. - Cables that exhibit ‘Cold Flow’ characteristics. See technical section for installation rules and regulations Group II Cable Glands CABLE GLAND SELECTION TABLE Entry Thread Size 'F' Size Ref. A Cable Acceptance Details Outer Sheath 'B' Hexagon Dimensions Across Flats Across Corners 'T' — Metric entry threads are 1.5mm pitch as standard, 15mm length of thread. All dimensions in millimetres (except * where dimensions are in inches). Features Provides a barrier seal to the individual insulated cores within the cable and prevents entry of the products of an explosion into the cable. The required number of holes for the cores are punched in the seal by means of a special tool to suit the core size. Provides armour clamping using one clamping arrangement for all armour / braid types. Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer sheath. Deluge protection option available, contact Hawke Technical Sales for details. Manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard. CABLE GLAND SIZE FOR CORE SIZE AND NUMBER Max. No. Cores Cross Sectional Area mm² of Cores 1.5 2.5 4.0 6.0 10.0 7 A&B A&B B&C C C 4 B 3 B PUNCH TOOL SIZE DETAILS Punch Ref. No. 1 No. 2 Cores C.S.A.mm² 1.5 - 2.5 4.0 - 6.0 Deluge protection option available. Ordering Information To select the correct size punch tool, please see table. Format for ordering is as follows: Cable Gland Type Punch Tool Required Brass Brass Punch Tool No. 1 Punch Tool No. 1 Alternative certification options available: Technical Data Flameproof Exd IIC Gb, Increased Safety Exe IIC Gb and Dust Extb IIIC Db II 2 GD. Certificate No’s: Baseefa06ATEX0056X and IECEx BAS 06.0013X. Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC. Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31. Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X. Deluge Protection to DTS01 (Deluge Seal Optional). Operating Temperature Range: -60°C to +80°C. Assembly Instruction Sheet: AI 312.
Open the catalog to page 12 Pages
24 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
4 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
2 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
12 Pages
83 Pages
75 Pages
12 Pages
8 Pages