Technical Specifications:
- The cable glands are certified for Flameproof Exd and Increased Safety Exe, suitable for hazardous areas (Zone 1, Zone 2, Zone 21, Zone 22) and gas groups IIA, IIB, and IIC.
- Certification numbers include Baseefa06ATEX0058X and IECEx BAS 06.0015X.
- Compliant with standards IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7, IEC/EN 61241-0, and IEC/EN 61241-1.
- Ingress protection ratings are IP66, IP67, and IP68 (30 meters for 7 days) according to IEC/EN 60529 and NEMA 4X.
- Deluge protection is provided according to DTS01.
- Operating temperature range is from -60°C to +80°C.
- Alternative certifications include Exe II, BR-Exd IIC / Exe II, GOST R-Exe IIU, and approvals for Kazakhstan and marine use.

Features:
- Provides a barrier seal to prevent explosion products from entering the cable.
- Ensures even distribution of the compound for a secure barrier seal.
- Allows for inspection and repair of external voids if necessary.
- Offers armour clamping for various types and a deluge seal to prevent moisture ingress.
- Manufactured in materials such as Brass, Nickel Plated Brass, 316 Stainless Steel, or Aluminium.

Applications:
- Suitable for outdoor or indoor use with various cable types including single wire armour, wire braid, and steel tape armour.
- Ideal for cables that are not compact or circular, have tape bedding, or hygroscopic fillers.
- Suitable for enclosures with ignition sources in gas group IIC or Zone 1 areas.

Ordering Information:
- The ordering format includes the alternative clamping ring (AR) option.
- A selection table provides details on size references, entry thread sizes, and cable acceptance details.
- Dimensions are provided in millimeters, with metric entry threads having a 1.5mm pitch as standard.
See more

Catalog excerpts

ICG 653/UNIVERSAL Cable glands-1

Cable Glands ICG 653/UNIVERSAL Hazardous Area 88 Flameproof Exd & Increased Safety Exe & Restricted Dual Certified ATEX / IECEx 15.0mm Inspectable Compound Deluge Boot • Outdoor or indoor use. • For use with single wire armour ‘W’, wire braid ‘X’, steel tape armour ‘Z’, elastomer and plastic insulated cables. • For particular use with:- Armour/Braid 'C' - Cables that are not effectively filled, compact and/or circular, Ø 'B' Ø 'E' Ø 'D' Entry Thread Metric Entry Application 'G' Approx (Fully Compressed Length) have tape bedding or have hygroscopic fillers. - Cables that exhibit ‘Cold Flow’ characteristics. - Enclosures containing an ignition source in gas group IIC areas or containing an ignition source in a Zone 1 area. • See technical section for installation rules and regulations. CABLE GLAND SELECTION TABLE Entry Thread Size Size Metric Ref. Os O A B C C2 D E F M20 M20 M20 M25 M32 M40 M50 M63 M75 NPT * Standard or Option ½" ½" ¾" or ½" 1" or ¾" 1¼" or 1" 1½" or 1¼" 2" or 1½" 2½" or 2" 3" or 2½" Hexagon Dimensions Cable Acceptance Details Inner Sheath / Cores Armour / Braid ‘C’ Max. Over Max Inner Max. No. of Outer Sheath ‘B’ Cores ‘D’ Sheath ‘E’ Cores Min Max Orientation 1 Orientation 2 8.9 10.0 6 5.5 12.0 0.8 / 1.25 0.0 / 0.8 8.9 10.0 6 9.5 16.0 0.8 / 1.25 0.0 / 0.8 11.0 12.5 10 12.5 20.5 0.8 / 1.25 0.0 / 0.8 16.2 18.4 21 16.9 26.0 1.25 / 1.6 0.0 / 0.7 21.9 24.7 42 22.0 33.0 1.6 / 2.0 0.0 / 0.7 26.3 29.7 60 28.0 41.0 1.6 / 2.0 0.0 / 0.7 37.1 41.7 80 36.0 52.6 1.8 / 2.5 0.0 / 1.0 47.8 53.5 100 46.0 65.3 1.8 / 2.5 0.0 / 1.0 59.0 66.2 / 65.3¹ 120 57.0 78.0 1.8 / /2.5 0.0 / 1.0 'G' Across Flats Across Corners 24.0 24.0 30.0 36.0 46.0 55.0 65.0 80.0 95.0 26.5 26.5 32.5 39.5 50.5 60.6 70.8 88.0 104.0 67.0 67.0 67.0 73.6 78.0 82.4 88.7 92.7 99.4 All dimensions in millimetres (except * where dimensions are in inches). Metric entry threads are 1.5mm pitch as standard, 15mm length of thread. ¹ Smaller value is applicable when selecting reduced NPT entry option. Note: Larger sizes are available. Technical Data • Flameproof Exd and Increased Safety Exe II 2 GD ExtD A21. • Certificate No’s: Baseefa06ATEX0058X and IECEx BAS 06.0015X. • Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC. • Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7, IEC/EN 61241-0 and IEC/EN 61241-1. • Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X. • Deluge Protection to DTS01. • Operating Temperature Range: -60°C to +80°C. • Assembly Instruction Sheet: AI 301. • Alternative certification options available: Exe II BR-Exd IIC / Exe II Exd IIC / Exe II GOST R-Exe IIU GOST K- Approved for use in Kazakhstan DNV Marine Approval ABS Marine Approval Features • Provides a barrier seal to the individual insulated cores within the cable and prevents entry of the products of an explosion into the cable. • Assembly of the cable gland compresses and distributes the compound evenly to create a barrier seal at the point of entry into the enclosure. • The compound chamber may be separated from the cured compound • • • • • to ensure that the chamber has been effectively filled. If required, external voids can be repaired. Provides armour clamping, using one clamping arrangement for all armour / braid types. Provides an outer deluge seal to prevent moisture ingress to the cable armour / braid. Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer sheath. Manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard. Alternative Reversible Armour Clamping Rings (RAC) Size Ref. B C C2 D E F SELECTION TABLE Steel Wire Armour / Braid / Tape Orientation 1 Orientation 2 0.9 - 1.25 0.5 - 0.9 1.2 - 1.6 0.6 - 1.2 1.2 - 1.6 0.6 - 1.2 1.45 - 1.8 1.0 - 1.45 1.45 - 1.8 1.0 - 1.45 1.45 - 1.8 1.0 - 1.45 Ordering Information Format for ordering is as follows: Alternative Clamping Ring (AR), add suffix AR to ordering information. Cable Gland Type ICG 653/UNIV Size C Thread M32 (OPTIONAL) AR Cable Gland Type ICG 653/UNIV Size C Thread 1 1⁄4"NPT (OPTIONAL) AR Two part sealing compound and assembly instructions are supplied with the cable gland. Connection Solutions www.ehawke.com HPG01 UPD 090610

 Open the catalog to page 1

All Hawke International U.K catalogs and technical brochures

  1. 501/RCG

    2  Pages

  2. PL630

    1  Page

  3. PL626

    1  Page

  4. PL620

    1  Page

  5. PL615

    1  Page

  6. PL612

    1  Page

  7. 321/R

    1  Page

  8. 321

    1  Page

  9. 114

    1  Page

  10. 151/RAC

    1  Page

  11. 150/RAC

    1  Page

  12. 153/RAC

    1  Page

  13. 123

    1  Page

  14. 121

    1  Page

  15. 701

    1  Page

  16. 153/X

    1  Page

  17. 755

    1  Page

  18. 753

    1  Page

  19. 711

    1  Page

  20. 710

    1  Page

  21. 653/T

    1  Page

  22. 623

    1  Page

  23. 453/T

    1  Page

  24. 453/RAC

    1  Page

  25. PSG 553/RAC

    1  Page

  26. 501/453/UNIV

    1  Page

  27. 501/453/RAC

    1  Page

  28. HB Type

    1  Page

  29. SK-Series

    4  Pages

  30. EJB Series

    1  Page

Archived catalogs

  1. Cable Glands

    83  Pages

  2. Ex Connectors

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.