Ordering Information: The format for ordering includes specifying the cable gland or connector type, size, and thread. An example is '755 C 1" NPT'. A two-part sealing compound and assembly instructions are provided with the cable gland.
Features: The cable gland provides a barrier seal between insulated conductors to prevent explosion products from entering the cable. It ensures even distribution of the compound for a barrier seal at the enclosure entry point. It includes an outer deluge seal to prevent moisture ingress, indicated by a red color for hazardous locations. The gland offers cable retention and a low smoke, zero halogen seal on the outer jacket. It is available in brass, nickel-plated brass, 316 stainless steel, or aluminum, with nickel-plated brass NPT entries as standard.
Application: Suitable for outdoor or indoor use with armored jacketed cables as per NEC regulations. Installation rules and regulations are detailed in the technical section.
Technical Data: The product is UL listed (No: E84940) and suitable for use in various hazardous locations, including Class 1, Division 2, and Class 1, Zone 2, with specific gas group classifications. It meets several construction and test standards, including UL 2225 and IEC/EN 60079 series. It offers ingress protection ratings of IP66, IP67, and IP68, and deluge protection to DTS01. The operating temperature range is -50°C to +60°C (UL) and -60°C to +80°C (ATEX/IECEx). Alternative certifications include DNV Marine Approval and ABS Marine Approval.
Cable Gland Selection Table: The table provides detailed specifications for various sizes, including entry thread size, cable acceptance details, and dimensions. It covers sizes from Os to F, with both NPT and metric options available. Dimensions are provided in inches, with metric entry threads having a 1.5mm pitch as standard.
See more

Catalog excerpts

755-1

Cable Glands North American Cable Glands/Connectors Explosion Proof IECEx and ATEX Approved Flameproof Exd, Increased Safety Exe and Restricted Breathing ExnR (Note: Dual Marked UL & ATEX as standard). 'G' Approx (Fully Compressed Length) Nickel Plated Hub • Outdoor or indoor use. • For use with armoured jacketed cable, as permitted by the NEC. • See technical section for installation rules and regulations. CABLE GLAND SELECTION TABLE Entry Thread Size Size Ref. Hexagon Dimensions Cable Acceptance Details Inner Jacket / Cores Steel Wire Armour Across Across Flats Corners All dimensions in inches (except * where dimensions are in millimetres). Metric entry threads are 1.5mm pitch as standard, 15mm length of thread. ¹ Smaller value is applicable when selecting standard NPT entry option. ² Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner jacket diameter is 0.43 3 UL listing only applies to Steel Wire Armour. Technical Data • UL Listing No: E84940. • Suitable for use in: • Class 1, Division 2, Gas Groups A, B, C and D • Class 1, Zone 2, Gas Groups IIA, IIB and IIC • AExd IIC and AExe II Class 1, Zone 2. • Flameproof Exd, Increased Safety Exe II 2 GD and Restricted Breathing ExnR II 3G. • Certificate No’s: Sira 06ATEX1295X and IECEx SIR 06.0082X. • Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC. • Construction and Test Standards: UL 2225, IEC/EN 60079-0, • • • • • IEC/EN 60079-1, IEC/EN 60079-7, IEC/EN 60079-15, IEC/EN 61241-0 and IEC/EN 61241-1. Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X. Deluge Protection to DTS01. Operating Temperature Range: -50°C to +60°C (UL) and -60°C to +80°C (ATEX / IECEx). Assembly Instruction Sheet: AI 319 (UL) and AI 382 (ATEX / IECEx). Alternative certification options available: DNV Marine Approval GOST R-Exe IIU • Provides a barrier seal between the individual insulated conductors • • • • • within the cable and prevents entry of the products of an explosion into the cable. Assembly of the cable gland compresses and distributes the compound evenly to effect a barrier seal at the point of entry into the enclosure. Provides an outer deluge seal to prevent moisture ingress to the cable armour and enclosure. Deluge seal is coloured red to indicate Hazardous Location product. Provides a cable retention and low smoke and fume, zero halogen seal onto the cables outer jacket. Manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard. Ordering Information Format for ordering is as follows: Cable Gland / Connector Type 755 Two part sealing compound and assembly instructions are supplied with the cable gland. Connection Solutions www.ehawke.com