• Products
  • Catalogs
  • News & Trends
  • Exhibitions

501/453/RAC

501/453/RAC

Product catalog summary
Overview: This document provides technical specifications and guidelines for Group II Cable Glands, which are designed for flameproof, increased safety, and dust protection applications. These cable glands are certified under ATEX, IECEx, and c CSA us standards, suitable for use in various hazardous zones and divisions.

Application:
  • Suitable for outdoor or indoor use.
  • Compatible with single wire armour, wire braid, steel tape armour, and elastomer/plastic insulated cables.
  • Refer to the technical section for installation rules and regulations.

Features:
  • Universal armour clamping for all armour/braid types.
  • Seals on the cable's inner sheath and provides retention and low smoke, zero halogen seal on the outer sheath.
  • Available in Brass, Nickel Plated Brass, 316 Stainless Steel, or Aluminium.

Technical Data:
  • ATEX/IECEx certifications for flameproof and increased safety applications in Zones 1, 2, 21, and 22.
  • Ingress Protection ratings of IP66, IP67, and IP68 (30 meters for 7 days).
  • Operating temperature range from -60°C to +100°C.

Selection and Ordering:
  • Various sizes and thread options available, detailed in the selection table.
  • Ordering format includes type, size, thread, and material, with options for alternative clamping rings and seals.

Certifications:
  • ATEX/IECEx: Flameproof Exd IIC Gb, Increased Safety Exe IIC Gb, Dust Extb IIIC Db.
  • c CSA us: Flameproof AExd IIC Gb, Increased Safety AExe IIC Gb, Dust AExtD Zone 21.

Standards:
  • Construction and test standards include IEC/EN 60079 series and UL/CSA standards.
See more

Catalog excerpts

501/453/RAC-1

F Flameproof, Increased Safety, Dust Protection Class - Zones - Divisions Certified ATEX / IECEx / c CSA us Group II Cable Glands A Application Outdoor or indoor use. For use with single wire armour ‘W’, wire braid ‘X’, steel tape armour ‘Z’, elastomer and plastic insulated cables. See technical section for installation rules and regulations. CABLE GLAND SELECTION TABLE Entry Thread Size 'F' Size Ref. Hexagon Dimensions Cable Acceptance Details Inner Sheath ‘A’ Standard Seal Min. Armour / Braid 'C' Orientation 1 Across Flats Across Corners Technical Data Alternative certification options available: ATEX/IECEx Flameproof Exd IIC Gb, Increased Safety Exe IIC Gb and Dust Extb IIIC Db II 2 GD. Certificate No’s: Baseefa06ATEX0056X and IECEx BAS 06.0013X.Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC. Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7 and IEC/EN 60079-31. Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X. Deluge Protection to DTS01. (Deluge Seal Optional) Operating Temperature Range: -60°C to +100°C. Assembly Instruction Sheet: AI 302. Alternative Reversible Armour Clamping Rings (RAC) SELECTION TABLE Size Ref. B C C2 D E F c CSA us Flameproof AExd IIC Gb, Increased Safety AExe IIC Gb and Dust AExtD Zone 21. Explosion-proof Class 1 Division 2 Groups ABCD, Class II Division 2 Groups EFG, Class III. Certificate No’s: CSA1015065 for Marine Shipboard Cable. Construction and Test Standards: UL 60079-0, UL 60079-1, UL 60079-7, ISA 60079-31, CSA 22.2 No: 60079-0, CSA 22.2 No: 60079-1, CSA 22.2 No: 60079-7, Ordering Information CSA 22.2 No: 60079-31, UL 2225 Format for ordering is as follows: Alternative Clamping Ring (AR), add suffix AR to Features ordering information. Alternative Seal (S), add suffix S Provides armour clamping using one clamping arrangement for all to ordering information. armour / braid types. Cable Gland Provides a seal on the cables inner sheath. Size Thread Material (Optional) Type Provides a cable retention and low smoke and fume, zero halogen seal 501/453/RAC C M32 Brass AR onto the cables outer sheath. 501/453/RAC C 1 ¼" NPT Brass AR Manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel 501/453/RAC C M32 Brass S or Aluminium. 501/453/RAC C 1 ¼" NPT Brass S Brass NPT entries are nickel plated as standard.

 Open the catalog to page 1

All Hawke International U.K catalogs and technical brochures

  1. 501/RCG

    2  Pages

  2. PL630

    1  Page

  3. PL626

    1  Page

  4. PL620

    1  Page

  5. PL615

    1  Page

  6. PL612

    1  Page

  7. 321/R

    1  Page

  8. 321

    1  Page

  9. 114

    1  Page

  10. 151/RAC

    1  Page

  11. 150/RAC

    1  Page

  12. 153/RAC

    1  Page

  13. 123

    1  Page

  14. 121

    1  Page

  15. 701

    1  Page

  16. 153/X

    1  Page

  17. 755

    1  Page

  18. 753

    1  Page

  19. 711

    1  Page

  20. 710

    1  Page

  21. 653/T

    1  Page

  22. 623

    1  Page

  23. 453/T

    1  Page

  24. 453/RAC

    1  Page

  25. PSG 553/RAC

    1  Page

  26. 501/453/UNIV

    1  Page

  27. HB Type

    1  Page

  28. SK-Series

    4  Pages

  29. EJB Series

    1  Page

Archived catalogs

  1. Cable Glands

    83  Pages

  2. Ex Connectors

    8  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.