501/414 Cable Gland
1Pages

{{requestButtons}}

Catalog excerpts

501/414 Cable Gland - 1

Cable Glands 501/414 Hazardous Area 90 Flameproof Exd & Increased Safety Exe Dual Certified ATEX / IECEx Application 15.0mm 'G' Approx (Fully Compressed Length) Female Entry Thread Ø 'B' Male Entry Thread Metric Entry • Outdoor or indoor use. • For use with non-armoured elastomer and plastic insulated cables installed in conduit. • See technical section for installation rules and regulations. CABLE GLAND SELECTION TABLE Female Entry Thread Size Cable Acceptance Details Outer Sheath 'B' NPT * NPT # Standard Seal Alternative Seal (S) Standard or Metric Standard or Option Option Min. Max. Min. Max. Male Entry Thread Size Size Ref. Metric Os O A B C C2 D E F M20² M20² M20 M25 M32 M40 M50 M63 M75 ½" ½" ¾" or ½" 1" or ¾" 1¼" or 1" 11⁄2" or 11⁄4" 2" or 11⁄2" 21⁄2" or 2" 3" or 21⁄2" M20 M20 M20 M25 M32 M40 M50 M63 M75 - 3.0 7.5 11.0 13.0 19.0 25.0 31.5 42.5 54.5 8.0 11.9 14.3 20.2 26.5 32.5 4.4/42.31 56.3/54.31 68.2/65.31 8.5 9.5 15.5 22.0 27.5 39.0 48.5 13.4 15.4 21.2 28.0 34.8 46.5 58.3 Hexagon Dimensions 'G' Across Flats Across Corners 54.5 54.5 56.4 48.2 61.6 64.6 83.2 83.2 86.4 24.0 24.0 30.0 36.0 46.0 55.0 65.0 80.0 95.0 26.5 26.5 32.5 39.5 50.5 60.6 70.8 88.0 104.0 All dimensions in millimetres (except * where dimensions are in inches). Metric entry threads are 1.5mm pitch as standard. ¹ Smaller value is applicable when selecting reduced NPT male entry option. ² Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable inner sheath diameter is 10.9mm # NPT female thread sizes equivalent to those shown in the table for the male thread size are available. Hexagon dimensions as shown may alter. Technical Data • Flameproof Exd and Increased Safety Exe II 2 GD ExtD A21. • Certificate No’s: Baseefa06ATEX0056X and IECEx BAS 06.0013X. • Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC. • Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-1, IEC/EN 60079-7, IEC/EN 61241-0 and IEC/EN 61241-1. • Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X. • Deluge Protection to DTS01. • Operating Temperature Range: -60°C to +100°C. • Assembly Instruction Sheet: AI 310. • Alternative certification options available: Exe II Features • Provides a cable retention seal onto the cables outer sheath. • When used in Increased Safety applications, this cable gland may • • • be used with braided cable where the braid and the cables outer sheath pass into the enclosure. The braid must be suitably terminated into the enclosure. Provides female running coupler for cable gland or conduit entry. Manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. Brass NPT entries are nickel plated as standard. Exd IIC / Exe II GOST R-Exe IIU GOST K- Approved for use in Kazakhstan Ordering Information Format for ordering is as follows: Alternative Seal (S), add suffix S to ordering information. Cable Gland Type 501/414 Size C Thread M32 (OPTIONAL) S Cable Gland Type 501/414 Size C Thread 1 1⁄4"NPT (OPTIONAL) S Connection Solutions www.ehawke.com HPG01 UPD 090610

Open the catalog to page 1

All Hawke International U.K catalogs and technical brochures

  1. 501/RCG

    2 Pages

  2. PL630

    1 Pages

  3. PL626

    1 Pages

  4. PL620

    1 Pages

  5. PL615

    1 Pages

  6. PL612

    1 Pages

  7. 321/R

    1 Pages

  8. 321

    1 Pages

  9. 114

    1 Pages

  10. 151/RAC

    1 Pages

  11. 150/RAC

    1 Pages

  12. 153/RAC

    1 Pages

  13. 123

    1 Pages

  14. 121

    1 Pages

  15. 701

    1 Pages

  16. 153/X

    1 Pages

  17. 755

    1 Pages

  18. 753

    1 Pages

  19. 711

    1 Pages

  20. 710

    1 Pages

  21. 653/T

    1 Pages

  22. 623

    1 Pages

  23. 453/T

    1 Pages

  24. 453/RAC

    1 Pages

  25. PSG 553/RAC

    1 Pages

  26. 501/453/UNIV

    1 Pages

  27. 501/453/RAC

    1 Pages

  28. HB Type

    1 Pages

  29. SK-Series

    4 Pages

  30. EJB Series

    1 Pages

Archived catalogs

  1. Cable Glands

    83 Pages