321
1Pages

{{requestButtons}}

Catalog excerpts

321 - 1

Cable Glands Hazardous Area (Fully Compressed Length) G' Approx 15.0mm Increased Safety Exe Class - Zones - Divisions Certified ATEX / IECEx / c CSA us Application The 321 cable gland provides a seal on the outer cable sheath and is intended for use on non-armoured elastomer and plastic insulated cables. The cable gland certified Exe and is suitable for installation in Zone 1 (21) and Zone 2 (22) hazardous areas. Entry Thread Metric Entry CABLE GLAND SELECTION TABLE Entry Thread Size Size Ref. Cable Acceptance Details Hexagon Dimensions Across Flats Across Corners All dimensions in millimetres (except * where dimensions are in inches). 2K - F size metric entry threads are 1.5mm pitch as standard, 15mm length of thread. For G size glands and above, a 2mm pitch is supplied as standard, 20mm length of thread (1.5mm pitch with 15mm length of thread can be supplied) please specify when ordering. ¹ Smaller value is applicable when selecting reduced NPT entry option. ² Sizes Os and O are available with an M16 thread size. For O size with M16 thread, the maximum cable outer sheath diameter is 10.9mm Technical Data ATEX/IECEx Increased Safety Exe IIC Gb and Dust Extb IIIC Db II 2 GD. Certificate No’s: Baseefa06ATEX0059X and IECEx BAS 06.0016X. Suitable for use in Zone 1, Zone 2, Zone 21, Zone 22. Construction and Test Standards: IEC/EN 60079-0, IEC/EN 60079-7 and IEC/EN 60079-31. Ingress Protection: IP66, IP67 and IP 68 (30 metres for 7 days) to IEC/EN 60529 and NEMA 4X. Deluge Protection to DTS01. Operating Temperature Range: -60°C to +100°C. Assembly Instruction Sheet: AI 451. cCSAus Increased Safety AExe IIC and Dust AExtD Zone 21. Explosion-proof Class 1 Division 2, Class II Division 2 Groups EFG, Class III. Certificate No’s: CSA1205533 for Marine Shipboard Cable. Construction and Test Standards: UL 60079-0, UL 60079-7, ISA 60079-31. CSA 22.2 No: 60079-0, CSA 22.2 No: 60079-7, CSA 22.2 No: 60079-31, UL 2225 • When used in Increased Safety applications, this cable gland may be used with braided cable where the braid and the outer sheath pass into the enclosure. The braid must then be suitably terminated inside the enclosure. Note: Braided cable is classed as unarmoured cable in the EN/IEC 60079 series standards for Exe applications. • Manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. • Brass NPT entries are nickel plated as standard. Ordering Information Format for ordering is as follows: Certification required i.e. ATEX / IECEx Material & Finish i.e. Brass Nickel Plated Alternative Seal (S), add suffix S to ordering information. Cable Gland Type 321 321 Connection Solutions www.ehawke.com UPD 050215

Open the catalog to page 1

All Hawke International U.K catalogs and technical brochures

  1. 501/RCG

    2 Pages

  2. PL630

    1 Pages

  3. PL626

    1 Pages

  4. PL620

    1 Pages

  5. PL615

    1 Pages

  6. PL612

    1 Pages

  7. 321/R

    1 Pages

  8. 114

    1 Pages

  9. 151/RAC

    1 Pages

  10. 150/RAC

    1 Pages

  11. 153/RAC

    1 Pages

  12. 123

    1 Pages

  13. 121

    1 Pages

  14. 701

    1 Pages

  15. 153/X

    1 Pages

  16. 755

    1 Pages

  17. 753

    1 Pages

  18. 711

    1 Pages

  19. 710

    1 Pages

  20. 653/T

    1 Pages

  21. 623

    1 Pages

  22. 453/T

    1 Pages

  23. 453/RAC

    1 Pages

  24. PSG 553/RAC

    1 Pages

  25. 501/453/UNIV

    1 Pages

  26. 501/453/RAC

    1 Pages

  27. HB Type

    1 Pages

  28. SK-Series

    4 Pages

  29. EJB Series

    1 Pages

Archived catalogs

  1. Cable Glands

    83 Pages