To order, use the format: Alternative Clamping Ring (AR), add suffix AR to ordering information.
Example: 114/RAC C M32 AR or 114/RAC C 1 1⁄4"NPT AR.
Cable Gland Selection Table| Size Ref. | Male Entry Thread Size | Female Entry Thread Size | Cable Acceptance Details | Hexagon Dimensions |
|---|---|---|---|---|
| A | M20 ¾" or ½" | M20 | Min. 11.0 Max. 14.3 | Across Flats 30.0 Across Corners 32.5 |
| B | M25 1" or ¾" | M25 | Min. 13.0 Max. 20.2 | Across Flats 36.0 Across Corners 39.5 |
| C | M32 1¼" or 1" | M32 | Min. 19.0 Max. 26.5 | Across Flats 46.0 Across Corners 50.5 |
| C2 | M40 1½" or 1¼" | M40 | Min. 25.0 Max. 32.5 | Across Flats 55.0 Across Corners 60.6 |
| D | M50 2" or 1½" | M50 | Min. 31.5 Max. 44.4 | Across Flats 65.0 Across Corners 70.8 |
| E | M63 2½" or 2" | M63 | Min. 42.5 Max. 56.3 | Across Flats 80.0 Across Corners 88.0 |
| F | M75 3" or 2½" | M75 | Min. 54.5 Max. 68.2 | Across Flats 95.0 Across Corners 104.0 |
All dimensions are in millimetres, except where noted in inches. Metric entry threads have a 1.5mm pitch as standard.
Cable Glands 114 Industrial 120 15.0mm 'G' Approx (Fully Compressed Length) Female Entry Thread Ø 'B' Male Entry Thread Metric Entry Application • Outdoor or indoor use. • For use with non-armoured elastomer and plastic insulated cables installed in conduit. CABLE GLAND SELECTION TABLE Female Entry Thread Size Cable Acceptance Details Outer Sheath ‘B’ NPT * NPT # Standard Seal Alternative Seal (S) Standard or Metric Standard or Option Option Min. Max. Min. Max. Male Entry Thread Size Size Ref. Metric A B C C2 D E F M20 M25 M32 M40 M50 M63 M75 ¾" or ½" 1" or ¾" 1¼" or 1" 1½" or 1¼" 2" or 1½" 2½" or 2" 3" or 2½" M20 M25 M32 M40 M50 M63 M75 - 11.0 13.0 19.0 25.0 31.5 42.5 54.5 14.3 20.2 26.5 32.5 44.4 / 42.3¹ 56.3 / 54.3¹ 68.2 / 65.3¹ 8.5 9.5 15.5 22.0 27.5 39.0 48.5 13.4 15.4 21.2 28.0 34.8 46.5 58.3 Hexagon Dimensions 'G' Across Flats Across Corners 56.4 48.2 61.6 64.6 83.2 83.2 86.4 30.0 36.0 46.0 55.0 65.0 80.0 95.0 32.5 39.5 50.5 60.6 70.8 88.0 104.0 All dimensions in millimetres (except * where dimensions are in inches). Metric entry threads are 1.5mm pitch as standard. ¹ Smaller value is applicable when selecting reduced NPT male entry option. # NPT female thread sizes equivalent to those shown in the table for the male thread size are available. Hexagon dimensions as shown may alter. Technical Data • Construction and Test Standards: EN 50262. • Ingress Protection: IP66 to IEC/EN 60529 and NEMA 4X. • Operating Temperature Range: -60°C to +80°C. • Assembly Instruction Sheet: AI 394. Features • Provides a cable retention seal onto the cables outer sheath. • Provides female running coupler for cable gland or conduit entry. • Manufactured in Brass (standard), Nickel Plated Brass, 316 Stainless Steel or Aluminium. • Brass NPT entries are nickel plated as standard. Ordering Information Format for ordering is as follows: Alternative Clamping Ring (AR), add suffix AR to ordering information. Cable Gland Type 114/RAC Size C Thread M32 (OPTIONAL) AR Cable Gland Type 114/RAC Size C Thread 1 1⁄4"NPT (OPTIONAL) AR Connection Solutions www.ehawke.com HPG01 UPD 090610
Open the catalog to page 12 Pages
24 Pages
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
4 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
2 Pages
1 Page
1 Page
1 Page
2 Pages
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
1 Page
12 Pages
83 Pages
75 Pages
12 Pages
8 Pages