VB
1 /88Pages

VB

VB
1 /88Pages

Catalog excerpts

VB-1

Valve bank (directional seated valve) type VB Product documentation Operating pressure pmax: Flow rate Qmax:

 Open the catalog to page 1
VB-2

© by HAWE Hydraulik SE. The reproduction and distribution of this document, as well as the use and communication of its contents to others without explicit authorization, is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of patent or utility model applications. Brand names, product names and trademarks are not specifically indicated. In particular with regard to registered and protected names and trademarks, usage is subject to legal provisions. HAWE Hydraulik respects these legal provisions in all cases. HAWE Hydraulik cannot provide individual...

 Open the catalog to page 2
VB-5

Overview valve bank (directional seated valve) type VB The valve bank type VB combines valves in accordance with D 7300 and D 7300-12 to control independent consumers. The valve bank comprises multiple directional seated valves of the types G, WG etc., which are connected in parallel. The directional seated valves are ball valves, and have zero leakage when closed. They are ange-mounted on sub-plates. These subplates are clamped between the connection block (P and R port) and the end plate via tension rods. Pressure switches and pressure-limiting valves can be integrated into the pump lines...

 Open the catalog to page 5
VB-6

1.1 Ordering examples Example 1 VB 11 AM - 2/350 - F G45 S/11 - 2 - GM 24 For allocation of coding and main data, see Chapter 2.1, "ordering example" Directional valve bank for pipe connection (identical actuation for all directional valves) = Pressure connection (pump) = Reux port (to tank) = Consumer ports Connection block Directional valves End plate with extension Pressure switch

 Open the catalog to page 6
VB-7

- VB 11 FM - R5H5 - 1 - GM 24 Directional valve bank for mounting on a compact hydraulic power pack Pump order coding, e.g. KA 24 S/H 1.51 – A2/420 (in accordance with D 8010) For allocation of directional valve bank coding and main data, see Chapter 2.1, "ordering example" = Pressure connection (pump) = Return port = Pressure connection, e.g. for pressure gauge or measurement tting = Consumer port

 Open the catalog to page 7
VB-8

Available versions -GM 24 -WG 230 2.3 "Actuation and actuating solenoid" 2.4 "Valve sections" 2.5 "Intermediate plates" 2.4 "Valve sections" Pressure-limiting valve with pressure setting (bar), 2.2.1 "Connection block for pipe connection" 2.3 "Actuation and actuating solenoid" 2.2 "Connection block or adapter plate" 2.1 "Basic type and size" INFORMATION The forward slash indicates which valves (coding) belong to which actuation type (sequence). In this example: valves FR with actuation type M; valve N with actuation type H. 2.1 Basic type, size and connecting thread Basic type and size Type Flow...

 Open the catalog to page 8
VB-9

2.2 Connection block or adapter plate 2.2.1 Connection block for pipe connection Coding Pressure-limiting valve, xed, die-cast zinc housing Pressure-limiting valve, adjustable, die-cast zinc housing Pressure-limiting valve, xed, steel housing, for pressure surges in the return line (> 20 bar). Pressure-limiting valve, adjustable, steel housing, for pressure surges in the return line (> 20 bar). Without pressure-limiting valve

 Open the catalog to page 9
VB-10

2.2.2 Adapter plates for compact hydraulic power packs Coding Circuit symbol Without pressure-limiting valve Pressure-limiting valve in connection block on the hydraulic power pack Combination with connection blocks A...AB in accordance with D 6905 AB with compact hydraulic power packs o Without pressure-limiting valve Pressure-limiting valve in connection block on the hydraulic power pack Combination with two-stage valve NE21 in accordance with VB 21: Direct mounting D 7161 with compact hydraulic power packs 2.2.3 Adapter plates for mounting on tank Coding Circuit symbol Without pressure-limiting...

 Open the catalog to page 10
VB-11

2.3 Actuation and actuating solenoid Actuation Coding Actuation type see "Actuating solenoid - version with interchangeable solenoid" see "Actuating solenoid - version with compact solenoid" Circuit symbol Mechanical (sensing roller) Manual (sensing lever) o Manual (rotary knob)

 Open the catalog to page 11
VB-12

Actuating solenoid - version with interchangeable solenoid Coding Electrical connection Version with DIN plug EN 175 301-803 A ■ ■ X: without line connector G: with line connector L: with LED connector WG with a rectifier circuit in the line connector 5K, 10K: with cast-on cable 5 m, 10 m long Explosion-proof solenoid with terminal box not available for coding J, G INFORMATION An application-specic cable can be used by the customer. For cable tting, see D 7300-12 “Electrical data”. Relative duty cycle in accordance with the chapter “Parameters” must be observed! INFORMATION The protection class...

 Open the catalog to page 12
VB-13

Actuating solenoid - version with compact solenoid Coding Electrical connection Version with central plug connector MSD 2 for 12 V DC size 0, MSD 1 for size 1 24 V DC as per D 7163 48 V DC Nominal voltage X: without line connector G: with line connector Version with DIN plug EN 175 301-803 A Version with adapter for DIN plug in accordance with EN 175 301-803 A ■ ■ 24 V DC A: without line connector 48 V DC N: with line connector in accordance with 98 V DC DIN 7163 Version with adapter for DIN plug in accordance with EN 175 301-803 A Size 0: MSD 2 - MSD 3 and MSD 4-209 P10 Size 1: MSD 1 - MSD 3...

 Open the catalog to page 13
VB-14

2.4 Valve sections 2.4.1 Valve sections without pressure switch Ordering example VB 01 VB 11 2.1 "Connecting thread" Valve section Coding Circuit symbol Simplied circuit symbol Idle circulation valve Normally open contact P d R with consumer port A in P Idle circulation valve N/C contact P d R - Idle circulation valve Normally open contact P d R HAWE Hydrauli

 Open the catalog to page 14
VB-15

Circuit symbol Simplied circuit symbol 2/2-way valve Normally open contact P d A - 2/2-way valve Normally open contact P d A with check valve in P 2/2-way valve Normally open contact P d A with check valve in P 2/2-way valve Normally open contact AdR

 Open the catalog to page 15

All HAWE Hydraulik SE catalogs and technical brochures

  1. VR

    15  Pages

  2. BVE

    54  Pages

  3. SLC

    17  Pages

  4. BNG

    25  Pages

  5. BA

    45  Pages

  6. VP

    35  Pages

  7. VH

    6  Pages

  8. SL1

    15  Pages

  9. ROLV

    23  Pages

  10. NBVP 16

    68  Pages

  11. EM

    41  Pages

  12. CR

    4  Pages

  13. BVG 1

    13  Pages

  14. SMD

    15  Pages

  15. EDL

    34  Pages

  16. PSLF

    60  Pages

  17. PS

    20  Pages

  18. HSF

    4  Pages

  19. SWS

    12  Pages

  20. NSWP 2

    8  Pages

  21. SG

    42  Pages

  22. K61N

    17  Pages

  23. K60N

    19  Pages

  24. V30D

    60  Pages

  25. V80M

    30  Pages

  26. V30E

    51  Pages

  27. RZ

    12  Pages

  28. C40V

    47  Pages

  29. HR 080

    17  Pages

  30. HICON

    14  Pages

  31. INKA

    35  Pages

  32. FXU

    35  Pages

  33. V60N

    71  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.