V80M
30Pages

{{requestButtons}}

Catalog excerpts

V80M - 1

Variable displacement axial piston pump type V80M Product documentation Open circuit Nominal pressure pnom max: Peak pressure pmax: Displacement volume Vmax:

Open the catalog to page 1
V80M - 2

© by HAWE Hydraulik SE. The reproduction and distribution of this document as well as the use and communication of its contents to others without explicit authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of patent or utility model applications. Brand names, product names and trademarks are not specifically indicated. In particular with regard to registered and protected names and trademarks, usage is subject to legal provisions. HAWE Hydraulik respects these legal provisions in all cases. HAWE Hydraulik cannot provide...

Open the catalog to page 2
V80M - 4

Overview: variable displacement axial piston pump type V80M Variable displacement axial piston pumps adjust the geometric output volume from maximum to zero. As a result they vary the ow rate that is provided to the consumers. The variable displacement axial piston pump type V80M is designed for open circuits in mobile hydraulics and operates according to the swash plate principle. It is available with the option of a thru-shaft for operating with additional hydraulic pumps in series. The sturdy pump is particularly suitable for continuous operation in challenging applications. The range...

Open the catalog to page 4
V80M - 5

Available versions Circuit symbol -Z Combination with gear pump 2.10 "Flange version (output side)" Pressure setting (nominal pressure) (bar) 2.9 "Controller" 2.8 "Stroke limitation" Manufacturing series 2.7 "Swivel angle indicator" 2.6 "Thru-shaft" 2.5 "Seals" 2.4 "Flange version (input side)" 2.3 "Shaft journal" 2.2 "Rotation direction" 2.1 "Basic type and nominal size" 2.1 Basic type and nominal size Type Nominal pressure pnom (bar) Peak pressure pmax (bar) with charging pump 2.2 Rotation direction Coding

Open the catalog to page 5
V80M - 6

2.3 Shaft journal Coding Designation / standard Spline shaft Spline shaft Spline shaft 2.4 Flange version (input side) Coding with thru-shaft 2.7 Swivel angle indicator Coding without display with display with swivel angle pick-up (Hall sensor)

Open the catalog to page 6
V80M - 7

2.8 Stroke limitation Coding Stroke limitation adjustable (Factory setting: 202 cm3/rev) Stroke limitation xed with specification of the set displacement volume Vg (cm3/rev) 2.9 Controller Load-sensing controller Coding Load-sensing controller with integrated pressure limitation Pressure controller Coding Pressure controller with remote-control port for external pilot valve Additional, directly mounted electro proportional pressure-limiting valve Additional, directly mounted 2/2-way directional seated valve for one pump direction switching circuit Power controller Coding Power controller...

Open the catalog to page 7
V80M - 8

Default setting Bypass orice Electro proportional valve pressure limitation standby pressure Electrical connection Power controller Torque adjusting screw Adjustable to 20% to 100% of desired 166 Nm/revolution max. torque Torque increase Torque reduction Electro proportional valve Torque increase Electro proportional valve Torque reduction HAWE Hydraulik

Open the catalog to page 8
V80M - 9

2.9.1 Pressure controller P P-controllers are pressure controllers with xed pressure setting. As soon as the pump pressure exceeds the set value, the pressure controller reduces the swivel angle of the pump and adjusts the pressure level to a constant value. Depending on the controller type, the pressure is set either using an adjusting screw directly on the controller or using an external pilot valve on port X. Coding P System pressure is tapped within the controller (internal). 2.9.2 Load-sensing controller LSP The LSP controllers are ow controllers that generate a variable,...

Open the catalog to page 9
V80M - 10

2.9.3 Power controller L, Lf, Lf1, Lfe, Lfe1 L, Lf, Lf1, Lfe and Lfe1 controllers are power controllers whose characteristic curve is a perfect hyperbola. When the product of displacement volume times pressure exceeds the set value, the controller reduces the pump’s swivel angle. This protects the drive shaft, motor or gearbox from overloading (pB x Vg = constant). The power controllers are only available in combination with a pressure- or load-sensing controller. Coding LLSP Coding LfLSP

Open the catalog to page 10
V80M - 11

Coding LfeLSP 2.9.4 Flow controller V, EM.CH V controller The V controller is an electro-proportional ow controller that generates a variable ow rate depending on the speed. The controller adjusts the pump’s displacement volume based on an electrical input signal. The resulting ow rate depends on the displacement volume and speed. The required pilot pressure for adjusting the swivel angle is tapped internally. An external auxiliary pump or a pre-load valve is required to ensure reliable switching. Coding VLSP

Open the catalog to page 11
V80M - 12

EM.CH controller The electro-hydraulic delivery ow controller EM.CH adjusts the displacement volume of the pump between "zero" and "maximum" in proportion to an electrical input signal, (target 0 - 10 V or 0 - 20 mA). The power for the adjustment is taken from the high-pressure line. System pressures under 50 bar will require an auxiliary pump in addition (thru-shaft). The control system consists of the pump adjustment system, an NG 6 prop. directional valve and a swivel angle pick-up (coding 2) for actual value determination. Control electronics (coding CH, type DAC-4) compare the...

Open the catalog to page 12
V80M - 13

2.10 Flange version (output side) Coding V80M- e.g. mounting of HAWE pump with coding Prepared for thru-shaft (cover) ANSI B 92.1, FLAT ROOT SIDE FIT spline width deviating from the standard, s = 2.357-0.03 DAMAGE Pay attention to the maximum permissible drive torque, as the ange or shaft may be damaged otherwise. An additional support is to be provided for pump combinations. Additional versions on request.

Open the catalog to page 13
V80M - 14

3.1 General data Designation Variable displacement axial piston pump Axial piston pump according to the swash plate principle Flange mounting or foot bracket temporarily protected Drive/output torque max. permissible drive/output torque (Nm) Nominal size 200 Spline shaft D Installation position any Installation information see Chapter 5, "Installation, operation and maintenance information" Rotation direction Suction port Pressure connection Drain port Ventilation connection Hydraulic uid Hydraulic uid, according to DIN 51 524 Parts 1 to 3; ISO VG 10 to 68 according to DIN ISO 3448...

Open the catalog to page 14

All HAWE Hydraulik SE catalogs and technical brochures

  1. VR

    15 Pages

  2. BVE

    54 Pages

  3. SLC

    17 Pages

  4. BNG

    25 Pages

  5. BA

    45 Pages

  6. VB

    88 Pages

  7. VP

    35 Pages

  8. VH

    6 Pages

  9. SL1

    15 Pages

  10. NBVP 16

    68 Pages

  11. EM

    41 Pages

  12. CR

    4 Pages

  13. BVG 1

    13 Pages

  14. SMD

    15 Pages

  15. EDL

    34 Pages

  16. PSLF

    60 Pages

  17. PS

    20 Pages

  18. HSF

    4 Pages

  19. SWS

    12 Pages

  20. NSWP 2

    8 Pages

  21. SG

    42 Pages

  22. K61N

    17 Pages

  23. K60N

    19 Pages

  24. V30D

    60 Pages

  25. V30E

    51 Pages

  26. RZ

    12 Pages

  27. C40V

    47 Pages

  28. HR 080

    17 Pages

  29. HICON

    14 Pages

  30. INKA

    35 Pages

  31. FXU

    35 Pages

  32. ROLV

    23 Pages

  33. V60N

    71 Pages