Overview: The document provides comprehensive details on the V30D variable displacement axial piston pump, suitable for open circuits in industrial hydraulics. It highlights features such as low-noise emissions, durability, and a wide range of controllers, making it ideal for applications like hydraulic presses, marine uses, industrial plants, power pack assembly, and mining machines.
Available Versions and Main Data: Various versions of the V30D pump are detailed, including basic models and different controllers. Specifications include a nominal pressure of 350 bar, peak pressure of 420 bar, and geometric displacement of 250 cm3/U. Tables provide information on rotation directions, shaft and flange versions, seals, housing types, swash plate angle indicators, controllers, solenoid voltage, and stroke limitations.
Parameters: This section covers general parameters, characteristics, electric parameters, and pivoting angle pick-up for the V30D pump.
Dimensions: Detailed dimensions for different V30D pump types are provided, including V30D-045, V30D-075, V30D-095/115, V30D-140/160, and V30D-250. Information on swash plate angle indicators and controller dimensions is also included.
Assembly, Operation, and Maintenance Recommendations: Guidelines for intended use, assembly, operation, and maintenance are provided, including details on connections, installation positions, and tank installation.
Controller Types and Functions: The document describes various controllers used in the pumps, such as LS, LSN, LSP, LSD, Q, Qb, V, VH, N, P, Pb, PD5, L, Lf, and Lf1 controllers, each designed to regulate flow rates and pressures for system efficiency and safety.
Pressure and Flow Rate Adjustments: Pressure settings are adjustable via screws or external pilot valves, with specific ranges and factory-set values. Flow rates are determined by orifice size and pressure differences, with detailed tables for reference.
Technical Specifications: The pumps operate on the swash plate principle, with various mounting options and compatibility with different hydraulic fluids. Operating conditions include permissible pressures, rotation speeds, and temperature ranges.
Safety and Maintenance: Warnings emphasize the risks of incorrect pressure settings and the importance of monitoring pressure gauges. Maintenance recommendations include ensuring sufficient lubrication and observing specific installation positions.
Specifications: The document outlines specifications for V30D pumps, designed for hydraulic applications with a frequency range of 0 - 150 Hz and a dither amplitude of 20% to 40%. The pivoting angle pick-up operates with a voltage range of 10 to 30 V DC.
Dimensions and Types: Detailed dimensions and configurations for different pump types are provided, specifying ports for pressure, suction, bleeding, flushing, measurement fitting, and control oil connection.
Assembly, Operation, and Maintenance Recommendations: Pumps must be assembled and operated by qualified personnel, with recommendations for cleanliness, hydraulic fluid filling, and adherence to technical parameters and safety measures.
Installation Instructions: Pumps can be installed in various positions, with specific instructions for horizontal and vertical installations, appropriate connections, and the importance of bleeding and flushing ports.
Operating Instructions: Restrictions during cold start and warm-up phases are outlined, specifying temperature and viscosity ranges, and operational parameters for different phases.
Documentation and Safety Instructions: Ensure documentation is read thoroughly and accessible to staff, with updates maintained. Monitor pressure gauges to avoid injury from incorrect settings.
Hydraulic Fluid Purity and Filtering: Emphasizes the importance of filtering fresh hydraulic fluid to meet purity standards and adhering to cleanliness levels.
Planning Information: Key parameters for planning include nominal sizes, delivery flow, drive torque, and drive power, with formulas provided for calculations.
Additional Documentation: General operating manuals and specific documentation for various hydraulic components and systems are available.
See more

Catalog excerpts

V30D-1

Variable displacement axial piston pump type V30D Product documentation Open circuit Nominal pressure pnom max: Peak pressure pmax: Geometric displacement Vmax:

 Open the catalog to page 1
V30D-2

© by HAWE Hydraulik SE. The reproduction and distribution of this document as well as the use and communication of its contents to others without explicit authorisation is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of patent or utility model applications. Brand names, product names and trademarks are not specifically indicated. In particular with regard to registered and protected names and trademarks, usage is subject to legal provisions. HAWE Hydraulik respects these legal provisions in all cases. Printing date / document generated...

 Open the catalog to page 2
V30D-4

Overview: variable displacement axial piston pump type V30D Variable displacement axial piston pumps adjust the geometric output volume from maximum to zero. As a result they vary the ow rate that is provided to the consumers. The axial piston pump type V30D is designed for open circuits in industrial hydraulics and operate according to the swash plate principle. They are available with the option of a thru-shaft for operating additional hydraulic pumps in series. The sturdy pump is particularly suitable for continuous operation in challenging applications. The range of pump controllers allows...

 Open the catalog to page 4
V30D-5

Available versions, main data Circuit symbol: Order coding example: V30D Torque setting (Nm) Stroke limitation Controller Release Table 8 Controllers; Table 9 Solenoid voltage and version Swash plate angle indicator Housing version Seal Rotation direction Nominal size Table 7 Swash plate angle indicator Table 6 Housing versions Flange version Shaft version Table 10 Stroke limitation Table 4 Flange versions (input side) Table 3 Shaft versions Table 2 Rotation directions Table 1 Nominal size Basic type Table 1 Nominal size Coding Nominal pressure pnom (bar) Peak pressure pmax (bar) Higher pressures...

 Open the catalog to page 5
V30D-6

Table 2 Rotation directions Coding When looking at the shaft journal. Table 3 Shaft versions Coding Table 4 Flange versions (input side) Coding

 Open the catalog to page 6
V30D-7

Table 5 Seals Coding NBR, suitable for HFC, for restrictions, see "Assembly, operation and maintenance recommendations" Table 6 Housing version Coding Without thru-shaft, suction port 45° With thru-shaft, suction port 45° Without thru-shaft, suction port 90° (only V30D-140, V30D-160) With thru-shaft, suction port 90° (only V30D-140, V30D-160) Table 7 Swash plate angle indicator Coding Without display With display With pivoting angle pick-up (Hall sensor)

 Open the catalog to page 7
V30D-8

Table 8 Controllers Coding Load sensing controller Load sensing controller with integrated pressure limitation Load sensing controller with remote-control port for external pressure limitation Load sensing controller without integrated pressure limitation for parallel operation of multiple pumps Flow controller for setting a constant ow rate independently of the speed. Flow controller for setting a constant ow rate independently of the speed, for applications with high demands on accuracy Electric proportional delivery ow controller with increasing characteristic curve Hydraulic delivery ow...

 Open the catalog to page 8
V30D-9

Table 10 Stroke limitation Coding Prepared for power controller With adjustable stroke limitation (not possible in combination with pump controller type V, VH) Stroke limitation xed with specification of the set geometric displacement Vg (cm3/rev.) Order coding example V30D-075 RDGN-2-0-02/LSN-350 - C 426 Table 11 Flange version (output side) Coding V30D 1) ANSI B 92.1, FLAT ROOT SIDE FIT spline width deviating from the standard, s = 2.357-0.03 NOTE Pay attention to the maximum permissible drive torque, as the ange or shaft may be damaged otherwise. NOTE An additional support is to be provided...

 Open the catalog to page 9
V30D-10

Basic pump Controller type N, P, Pb, LS, Q, Qb Controller type LSN, LSP Cover for version without N, P, Pb, LS, LSN, LSP, Q, Qb Controller type V Controller type VH Cover for version without V or VH, without stroke limitation Cover for version without V or VH, with stroke limitation Controller type L, Lf1 Controller type LSD Controller type PD5 Cover for version without L, Lf1, LSD, PD5

 Open the catalog to page 10
V30D-11

Basic pump Controller type N, P, Pb, LS, Q, Qb Controller type LSN, LSP Cover for version without N, P, Pb, LS, LSN, LSP, Q, Qb Controller type V Controller type VH Cover for version without V or VH, without stroke limitation Cover for version without V or VH, with stroke limitation Controller type L, Lf1 Controller type LSD Controller type PD5 Cover for version without L, Lf1, LSD, PD5

 Open the catalog to page 11
V30D-12

Basic pump Control head without L, Lf1, LSD, PD5 (series) Control head for L, Lf1, LSD, PD5 Controller type N, P, Pb, LS, Q, Qb Controller type LSN, LSP Cover for version without N, P, Pb, LS, LSN, LSP, Q, Qb Controller type V Controller type VH Cover for version without V or VH, without stroke limitation Cover for version without V or VH, with stroke limitation Controller type L, Lf1 Controller type LSD Controller type PD5 Cover for version without L, Lf1, LSD, PD5

 Open the catalog to page 12
V30D-13

2.2.1 Controller LS, LSN, LSP, LSD The LS(N,P,D) controller is a delivery ow controller that generates a variable ow rate independently of the speed. It adapts the geometric displacement of the pump to the required ow rate of the consumer and regulates a constant difference between load pressure and pump pressure. ■ ■ ■ ■ LS: Without pressure limitation LSN: With integrated pressure limitation LSP: With remote-control port for external pressure limitation LSD: Without pressure limitation for parallel operation of several pumps The LSD controller is used if several pumps supply the same consumer....

 Open the catalog to page 13
V30D-14

pB operating pressure (bar); Q delivery ow (%) 1 pB operating pressure (bar); Q delivery ow (%) 1 Differential pressure Δp (stand-by pressure) Bypass throttle Differential pressure Δp (stand-by pressure) Maximum pressure pmax (pressure limitation) Bypass throttle LS Bypass throttle N For coding LSN with tapped plug closed

 Open the catalog to page 14

All HAWE Hydraulik SE catalogs and technical brochures

  1. VR

    15  Pages

  2. BVE

    54  Pages

  3. SLC

    17  Pages

  4. BNG

    25  Pages

  5. BA

    45  Pages

  6. VB

    88  Pages

  7. VP

    35  Pages

  8. VH

    6  Pages

  9. SL1

    15  Pages

  10. ROLV

    23  Pages

  11. EM

    41  Pages

  12. PS

    20  Pages

  13. K60N

    19  Pages

  14. V80M

    30  Pages

  15. V30E

    51  Pages

  16. RZ

    12  Pages

  17. C40V

    47  Pages

  18. HR 080

    17  Pages

  19. HICON

    14  Pages

  20. INKA

    35  Pages

  21. FXU

    35  Pages

  22. V60N

    71  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.