Catalog excerpts
Variable displacement axial piston pump type V30D Product documentation Open circuit Nominal pressure pnom max: Peak pressure pmax: Geometric displacement Vmax:
Open the catalog to page 1© by HAWE Hydraulik SE. The reproduction and distribution of this document as well as the use and communication of its contents to others without explicit authorisation is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of patent or utility model applications. Brand names, product names and trademarks are not specifically indicated. In particular with regard to registered and protected names and trademarks, usage is subject to legal provisions. HAWE Hydraulik respects these legal provisions in all cases. Printing date / document...
Open the catalog to page 2Overview: variable displacement axial piston pump type V30D Variable displacement axial piston pumps adjust the geometric output volume from maximum to zero. As a result they vary the ow rate that is provided to the consumers. The axial piston pump type V30D is designed for open circuits in industrial hydraulics and operate according to the swash plate principle. They are available with the option of a thru-shaft for operating additional hydraulic pumps in series. The sturdy pump is particularly suitable for continuous operation in challenging applications. The range of pump controllers...
Open the catalog to page 4Available versions, main data Circuit symbol: Order coding example: V30D Torque setting (Nm) Stroke limitation Controller Release Table 8 Controllers; Table 9 Solenoid voltage and version Swash plate angle indicator Housing version Seal Rotation direction Nominal size Table 7 Swash plate angle indicator Table 6 Housing versions Flange version Shaft version Table 10 Stroke limitation Table 4 Flange versions (input side) Table 3 Shaft versions Table 2 Rotation directions Table 1 Nominal size Basic type Table 1 Nominal size Coding Nominal pressure pnom (bar) Peak pressure pmax (bar) Higher...
Open the catalog to page 5Table 2 Rotation directions Coding When looking at the shaft journal. Table 3 Shaft versions Coding Table 4 Flange versions (input side) Coding
Open the catalog to page 6Table 5 Seals Coding NBR, suitable for HFC, for restrictions, see "Assembly, operation and maintenance recommendations" Table 6 Housing version Coding Without thru-shaft, suction port 45° With thru-shaft, suction port 45° Without thru-shaft, suction port 90° (only V30D-140, V30D-160) With thru-shaft, suction port 90° (only V30D-140, V30D-160) Table 7 Swash plate angle indicator Coding Without display With display With pivoting angle pick-up (Hall sensor)
Open the catalog to page 7Table 8 Controllers Coding Load sensing controller Load sensing controller with integrated pressure limitation Load sensing controller with remote-control port for external pressure limitation Load sensing controller without integrated pressure limitation for parallel operation of multiple pumps Flow controller for setting a constant ow rate independently of the speed. Flow controller for setting a constant ow rate independently of the speed, for applications with high demands on accuracy Electric proportional delivery ow controller with increasing characteristic curve Hydraulic delivery...
Open the catalog to page 8Table 10 Stroke limitation Coding Prepared for power controller With adjustable stroke limitation (not possible in combination with pump controller type V, VH) Stroke limitation xed with specification of the set geometric displacement Vg (cm3/rev.) Order coding example V30D-075 RDGN-2-0-02/LSN-350 - C 426 Table 11 Flange version (output side) Coding V30D 1) ANSI B 92.1, FLAT ROOT SIDE FIT spline width deviating from the standard, s = 2.357-0.03 NOTE Pay attention to the maximum permissible drive torque, as the ange or shaft may be damaged otherwise. NOTE An additional support is to be...
Open the catalog to page 9Basic pump Controller type N, P, Pb, LS, Q, Qb Controller type LSN, LSP Cover for version without N, P, Pb, LS, LSN, LSP, Q, Qb Controller type V Controller type VH Cover for version without V or VH, without stroke limitation Cover for version without V or VH, with stroke limitation Controller type L, Lf1 Controller type LSD Controller type PD5 Cover for version without L, Lf1, LSD, PD5
Open the catalog to page 10Basic pump Controller type N, P, Pb, LS, Q, Qb Controller type LSN, LSP Cover for version without N, P, Pb, LS, LSN, LSP, Q, Qb Controller type V Controller type VH Cover for version without V or VH, without stroke limitation Cover for version without V or VH, with stroke limitation Controller type L, Lf1 Controller type LSD Controller type PD5 Cover for version without L, Lf1, LSD, PD5
Open the catalog to page 11Basic pump Control head without L, Lf1, LSD, PD5 (series) Control head for L, Lf1, LSD, PD5 Controller type N, P, Pb, LS, Q, Qb Controller type LSN, LSP Cover for version without N, P, Pb, LS, LSN, LSP, Q, Qb Controller type V Controller type VH Cover for version without V or VH, without stroke limitation Cover for version without V or VH, with stroke limitation Controller type L, Lf1 Controller type LSD Controller type PD5 Cover for version without L, Lf1, LSD, PD5
Open the catalog to page 122.2.1 Controller LS, LSN, LSP, LSD The LS(N,P,D) controller is a delivery ow controller that generates a variable ow rate independently of the speed. It adapts the geometric displacement of the pump to the required ow rate of the consumer and regulates a constant difference between load pressure and pump pressure. ■ ■ ■ ■ LS: Without pressure limitation LSN: With integrated pressure limitation LSP: With remote-control port for external pressure limitation LSD: Without pressure limitation for parallel operation of several pumps The LSD controller is used if several pumps supply the same...
Open the catalog to page 13pB operating pressure (bar); Q delivery ow (%) 1 pB operating pressure (bar); Q delivery ow (%) 1 Differential pressure Δp (stand-by pressure) Bypass throttle Differential pressure Δp (stand-by pressure) Maximum pressure pmax (pressure limitation) Bypass throttle LS Bypass throttle N For coding LSN with tapped plug closed
Open the catalog to page 14Pressure adjustment Pressure range (bar) Factory-set pressure setting (bar) Maximum pressure pmax (N250)1) Maximum pressure pmax (N400) Pressure adjustment 1) Depending on the pressure setting, either a weak spring (N250) or a strong spring (N400) is installed. CAUTION Risk of injury on overloading components due to incorrect pressure settings! Risk of minor injury. ■ Always monitor the pressure gauge when setting and changing the pressure. NOTE Loosen the lock nut sufficiently before setting so that the sealing ring is not damaged.
Open the catalog to page 15All HAWE Hydraulik SE catalogs and technical brochures
-
VR
15 Pages
-
BVE
54 Pages
-
SLC
17 Pages
-
BNG
25 Pages
-
BA
45 Pages
-
Valve banks type BWN and BWH
23 Pages
-
VB
88 Pages
-
VP
35 Pages
-
VH
6 Pages
-
SL1
15 Pages
-
NBVP 16
68 Pages
-
EM
41 Pages
-
CR
4 Pages
-
BVG 1
13 Pages
-
SMD
15 Pages
-
EDL
34 Pages
-
PSLF
60 Pages
-
PS
20 Pages
-
HSF
4 Pages
-
SWS
12 Pages
-
NSWP 2
8 Pages
-
SG
42 Pages
-
K61N
17 Pages
-
K60N
19 Pages
-
V80M
30 Pages
-
V30E
51 Pages
-
RZ
12 Pages
-
Radial piston pump type R, RG
23 Pages
-
C40V
47 Pages
-
Mini hydraulic power pack type A
23 Pages
-
HR 080
17 Pages
-
HICON
14 Pages
-
INKA
35 Pages
-
FXU
35 Pages
-
ROLV
23 Pages
-
V60N
71 Pages
-
Product catalogue
299 Pages