V30D
1 /60Pages

V30D

V30D
1 /60Pages

Catalog excerpts

V30D-1

Variable displacement axial piston pump type V30D Product documentation Open circuit Nominal pressure pnom max: Peak pressure pmax: Geometric displacement Vmax:

 Open the catalog to page 1
V30D-2

© by HAWE Hydraulik SE. The reproduction and distribution of this document as well as the use and communication of its contents to others without explicit authorisation is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of patent or utility model applications. Brand names, product names and trademarks are not specifically indicated. In particular with regard to registered and protected names and trademarks, usage is subject to legal provisions. HAWE Hydraulik respects these legal provisions in all cases. Printing date / document generated...

 Open the catalog to page 2
V30D-4

Overview: variable displacement axial piston pump type V30D Variable displacement axial piston pumps adjust the geometric output volume from maximum to zero. As a result they vary the ow rate that is provided to the consumers. The axial piston pump type V30D is designed for open circuits in industrial hydraulics and operate according to the swash plate principle. They are available with the option of a thru-shaft for operating additional hydraulic pumps in series. The sturdy pump is particularly suitable for continuous operation in challenging applications. The range of pump controllers allows...

 Open the catalog to page 4
V30D-5

Available versions, main data Circuit symbol: Order coding example: V30D Torque setting (Nm) Stroke limitation Controller Release Table 8 Controllers; Table 9 Solenoid voltage and version Swash plate angle indicator Housing version Seal Rotation direction Nominal size Table 7 Swash plate angle indicator Table 6 Housing versions Flange version Shaft version Table 10 Stroke limitation Table 4 Flange versions (input side) Table 3 Shaft versions Table 2 Rotation directions Table 1 Nominal size Basic type Table 1 Nominal size Coding Nominal pressure pnom (bar) Peak pressure pmax (bar) Higher pressures...

 Open the catalog to page 5
V30D-6

Table 2 Rotation directions Coding When looking at the shaft journal. Table 3 Shaft versions Coding Table 4 Flange versions (input side) Coding

 Open the catalog to page 6
V30D-7

Table 5 Seals Coding NBR, suitable for HFC, for restrictions, see "Assembly, operation and maintenance recommendations" Table 6 Housing version Coding Without thru-shaft, suction port 45° With thru-shaft, suction port 45° Without thru-shaft, suction port 90° (only V30D-140, V30D-160) With thru-shaft, suction port 90° (only V30D-140, V30D-160) Table 7 Swash plate angle indicator Coding Without display With display With pivoting angle pick-up (Hall sensor)

 Open the catalog to page 7
V30D-8

Table 8 Controllers Coding Load sensing controller Load sensing controller with integrated pressure limitation Load sensing controller with remote-control port for external pressure limitation Load sensing controller without integrated pressure limitation for parallel operation of multiple pumps Flow controller for setting a constant ow rate independently of the speed. Flow controller for setting a constant ow rate independently of the speed, for applications with high demands on accuracy Electric proportional delivery ow controller with increasing characteristic curve Hydraulic delivery ow...

 Open the catalog to page 8
V30D-9

Table 10 Stroke limitation Coding Prepared for power controller With adjustable stroke limitation (not possible in combination with pump controller type V, VH) Stroke limitation xed with specification of the set geometric displacement Vg (cm3/rev.) Order coding example V30D-075 RDGN-2-0-02/LSN-350 - C 426 Table 11 Flange version (output side) Coding V30D 1) ANSI B 92.1, FLAT ROOT SIDE FIT spline width deviating from the standard, s = 2.357-0.03 NOTE Pay attention to the maximum permissible drive torque, as the ange or shaft may be damaged otherwise. NOTE An additional support is to be provided...

 Open the catalog to page 9
V30D-10

Basic pump Controller type N, P, Pb, LS, Q, Qb Controller type LSN, LSP Cover for version without N, P, Pb, LS, LSN, LSP, Q, Qb Controller type V Controller type VH Cover for version without V or VH, without stroke limitation Cover for version without V or VH, with stroke limitation Controller type L, Lf1 Controller type LSD Controller type PD5 Cover for version without L, Lf1, LSD, PD5

 Open the catalog to page 10
V30D-11

Basic pump Controller type N, P, Pb, LS, Q, Qb Controller type LSN, LSP Cover for version without N, P, Pb, LS, LSN, LSP, Q, Qb Controller type V Controller type VH Cover for version without V or VH, without stroke limitation Cover for version without V or VH, with stroke limitation Controller type L, Lf1 Controller type LSD Controller type PD5 Cover for version without L, Lf1, LSD, PD5

 Open the catalog to page 11
V30D-12

Basic pump Control head without L, Lf1, LSD, PD5 (series) Control head for L, Lf1, LSD, PD5 Controller type N, P, Pb, LS, Q, Qb Controller type LSN, LSP Cover for version without N, P, Pb, LS, LSN, LSP, Q, Qb Controller type V Controller type VH Cover for version without V or VH, without stroke limitation Cover for version without V or VH, with stroke limitation Controller type L, Lf1 Controller type LSD Controller type PD5 Cover for version without L, Lf1, LSD, PD5

 Open the catalog to page 12
V30D-13

2.2.1 Controller LS, LSN, LSP, LSD The LS(N,P,D) controller is a delivery ow controller that generates a variable ow rate independently of the speed. It adapts the geometric displacement of the pump to the required ow rate of the consumer and regulates a constant difference between load pressure and pump pressure. ■ ■ ■ ■ LS: Without pressure limitation LSN: With integrated pressure limitation LSP: With remote-control port for external pressure limitation LSD: Without pressure limitation for parallel operation of several pumps The LSD controller is used if several pumps supply the same consumer....

 Open the catalog to page 13
V30D-14

pB operating pressure (bar); Q delivery ow (%) 1 pB operating pressure (bar); Q delivery ow (%) 1 Differential pressure Δp (stand-by pressure) Bypass throttle Differential pressure Δp (stand-by pressure) Maximum pressure pmax (pressure limitation) Bypass throttle LS Bypass throttle N For coding LSN with tapped plug closed

 Open the catalog to page 14

All HAWE Hydraulik SE catalogs and technical brochures

  1. VR

    15  Pages

  2. BVE

    54  Pages

  3. SLC

    17  Pages

  4. BNG

    25  Pages

  5. BA

    45  Pages

  6. VB

    88  Pages

  7. VP

    35  Pages

  8. VH

    6  Pages

  9. SL1

    15  Pages

  10. ROLV

    23  Pages

  11. NBVP 16

    68  Pages

  12. EM

    41  Pages

  13. CR

    4  Pages

  14. BVG 1

    13  Pages

  15. SMD

    15  Pages

  16. EDL

    34  Pages

  17. PSLF

    60  Pages

  18. PS

    20  Pages

  19. HSF

    4  Pages

  20. SWS

    12  Pages

  21. NSWP 2

    8  Pages

  22. SG

    42  Pages

  23. K61N

    17  Pages

  24. K60N

    19  Pages

  25. V80M

    30  Pages

  26. V30E

    51  Pages

  27. RZ

    12  Pages

  28. C40V

    47  Pages

  29. HR 080

    17  Pages

  30. HICON

    14  Pages

  31. INKA

    35  Pages

  32. FXU

    35  Pages

  33. V60N

    71  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.