Pressure switch type DG 2025-1

Piston-type pressure switch Operating pressure pmax: 700 bar

 Open the catalog to page 1
Pressure switch type DG 2025-2

© by HAWE Hydraulik SE. The reproduction and distribution of this document, as well as the use and communication of its contents to others without explicit authorization, is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of patent or utility model applications. Brand names, product names and trademarks are not specifically indicated. In particular with regard to registered and protected names and trademarks, usage is subject to legal provisions. HAWE Hydraulik respects these legal provisions in all cases. HAWE Hydraulik cannot provide individual...

 Open the catalog to page 2
Pressure switch type DG 2025-4

Pressure switches open and close an electrical contact at a previously defined pressure. As soon as the pressure is reached, a further work step is started or stopped by an electrical signal. ■ Option of integration with the HAWE modular system ■ General hydraulic systems

 Open the catalog to page 4
Pressure switch type DG 2025-5

Available versions Circuit symbol Ordering example Pressure setting (factory-set, optional), bar ■ Series: setting with increasing pressure ■ Coding F: setting with decreasing pressure Low-temperature seal configurable only with DG 35 -X. and DG 364 -X. Their micro switches are installed with gold contacts. Type Description Pressure setting (bar) Operating pressure (bar) pS-min - pS-max pmax DG 1 R Pipe connection, scale DG 1 RF Pipe connection, scale, front ring for control panel installa DG 1 RU Pipe connection, scale mounted with 180° rotation (for 20 - 600 "suspended" installation) DG 1 RUF...

 Open the catalog to page 5
Pressure switch type DG 2025-6

Coding Electrical connection Protection class DG 1 R (IEC 60529) DG 1 RF (without line connector) M12x1 (in compliance with DESINA) IP 2.3 Adjustment devices Coding

 Open the catalog to page 6
Pressure switch type DG 2025-7

Coding Connection type without coding Directly using a type-B pipe screw connection in accordance with DIN 3852-2 Connection thread G 1/4 or G 1/2 A (ISO 228-1) With a DIN 16283 union nut (pressure gauge screw fitting, e.g. DIN 16270) without coding Manifold mounting - YS 6 Tapered cone 06 and 08 for a cutting ring and union nut - Y6 Pipe bracket 06 and 08 for a pipe screw connection

 Open the catalog to page 7
Pressure switch type DG 2025-8

3.1 General data Designation Tightening torque Installation position Hydraulic fluid Cleanliness level Hydraulic data Type DG 35 -X..-KB Type DG 364 -X..-KB temperature range Speed of pressure change Pressure setting pS-min - pS-max Operating pressure Pressure switch Spring-loaded piston-type pressure switch Pipe connection, manifold mounting ■ DG 1: Galvanised steel housing ■ DG 3: Zinc die casting housing ■ DG 1 R.. = Vertical, sideways scale, hydraulic part at the bottom Hydraulic fluid, according to DIN 51 524 Parts 1 to 3; ISO VG 10 to 68 according to DIN ISO 3448 Optimal operating range:...

 Open the catalog to page 8
Pressure switch type DG 2025-10

Switching operations Electrical connection Reference values approx. 2000/h max. (roughly equally distributed). Note the number of possible switching cycles; see below. Switching accuracy * 2 to 3 % (repeat accuracy for increasing pressure!) product assembly instructions

 Open the catalog to page 10
Pressure switch type DG 2025-11

Maximum supply voltage < 50 V AC or 75 V DC Umax Switching current Imin To ensure a safe contact, the current must not fall below certain minimum values: When deactivating pumps directly, be aware of a potential afterrun caused by mass action. Also available for delivery with preset pressure. ■ DG 33-600 (setting for increasing pressure) ■ DG 33-600 F (setting for decreasing pressure) Pressure increases Pressure drops The tables only contain approximate reference values. Use a pressure gauge to establish a more accurate switching point! ■ DG 1 R..: Using a setting knob on the pressure selection...

 Open the catalog to page 11
Pressure switch type DG 2025-12

DG 3..R: by hand with a wing bolt after loosening the wing nut DG 3..V: with turning knob DG 3..H: with turning knob after releasing (spanner) Switching pressures Switching differential between the upper switching point po as the pressure increases and the lower switching point as the pressure drops. The calculated pressure value pu = k · po can only be considered an approximate reference value. po/pÒ set response pressure; k factor 1 2 3 po/pÒ set response pressure; k factor = Upper switching point at which the device jumps from its idle position to its switching position during a pressure increase...

 Open the catalog to page 12
Pressure switch type DG 2025-13

Dimensions AH dimensions in mm, subject to change. 5 Setting knob for main switch O NOTICE For types DG 1.., the scale housing © must not be twisted relative to the hex (width across Hats 27) ® for functional-technical reasons!

 Open the catalog to page 13
Pressure switch type DG 2025-14

5 Setting knob for main switch 6 Fixing holes are rotated by 180° in version "U".

 Open the catalog to page 14
Pressure switch type DG 2025-15

Line connector can be mounted offset by 4x90° Hydraulic connection G 1/4 thread for pipe screw connection G 1/2 thread e.g. pressure gauge screw tting G 1/2 thread Fitting type X1 (example) from D 7065 DG.. can be tted in any direction

 Open the catalog to page 15
Pressure switch type DG 2025-16

Base plate hole pattern

 Open the catalog to page 16
Pressure switch type DG 2025-17

Wing bolt Wing nut Turn knob Turn knob Tapped journal with sealing edge Pipe connection with EO progressive ring and Pipe connection pieces union nut DG 3.. can be rotated in any direction around the pipe axis after loosening the clamping plate (by loosening M4).

 Open the catalog to page 17
Pressure switch type DG 2025-18

Observe the document B 5488 "General operating instructions for assembly, commissioning, and maintenance." This product is intended exclusively for hydraulic applications (fluid technology). The user must observe the safety measures and warnings in this document. Essential requirements for the product to function correctly and safely: ► All information in this documentation must be observed. This applies in particular to all safety measures and warnings. ► The product must only be assembled and put into operation by specialist personnel. ► The product must only be operated within the specified...

 Open the catalog to page 18
Pressure switch type DG 2025-19

Overloading components due to incorrect pressure settings. Risk of minor injury. ■ Pay attention to the maximum operating pressure of the pump, valves and fittings. ■ Always monitor the pressure gauge when setting and changing the pressure. Fine contamination can significantly impair the function of the product. Contamination can cause irreparable damage. Examples of fine contamination include: ■ Rubber particles from hoses and seals ■ Dirt due to assembly and maintenance ■ Chemical ageing of the hydraulic fluid New hydraulic fluid from the manufacturer may not have the required purity. Damage...

 Open the catalog to page 19

All HAWE Hydraulik SE catalogs and technical brochures

  1. VR

    15  Pages

  2. BVE

    54  Pages

  3. SLC

    17  Pages

  4. BNG

    25  Pages

  5. BA

    45  Pages

  6. VB

    88  Pages

  7. VP

    35  Pages

  8. VH

    6  Pages

  9. SL1

    15  Pages

  10. ROLV

    23  Pages

  11. NBVP 16

    68  Pages

  12. EM

    41  Pages

  13. CR

    4  Pages

  14. BVG 1

    13  Pages

  15. SMD

    15  Pages

  16. EDL

    34  Pages

  17. PSLF

    60  Pages

  18. PS

    20  Pages

  19. HSF

    4  Pages

  20. SWS

    12  Pages

  21. NSWP 2

    8  Pages

  22. SG

    42  Pages

  23. K61N

    17  Pages

  24. K60N

    19  Pages

  25. V30D

    60  Pages

  26. V80M

    30  Pages

  27. V30E

    51  Pages

  28. RZ

    12  Pages

  29. C40V

    47  Pages

  30. HR 080

    17  Pages

  31. HICON

    14  Pages

  32. INKA

    35  Pages

  33. FXU

    35  Pages

  34. V60N

    71  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.