Mini hydraulic power pack type A Product documentation operating pressure pmax: effective volume (tank):
Open the catalog to page 1© by HAWE Hydraulik SE. The reproduction and distribution of this document as well as the use and communication of its contents to others without explicit authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of patent or utility model applications. Brand names, product names and trademarks are not specifically indicated. In particular with regard to registered and protected names and trademarks, usage is subject to legal provisions. HAWE Hydraulik respects these legal provisions in all cases. HAWE Hydraulik cannot provide individual...
Open the catalog to page 2Overview of mini hydraulic power pack type A Compact hydraulic power packs are a type of hydraulic power pack. They are characterised by a highly compact design, since the motor shaft of the electric drive also acts as the pump shaft. Compact hydraulic power packs are designed to supply hydraulic circuits with hydraulic uid. The mini hydraulic power pack type A is characterised by its modular design. An external gear pump is ange-mounted onto the equipment rack in the hydraulic power pack. The oil tank is a round, plastic tank with an M14x1.5 lling screw. Version A 100 comes with a choice...
Open the catalog to page 4Available versions Circuit symbol Lifting version (H) Throttle * Lowering valve * 1: Lowering valve 2/2-poppet bypass valve 24 V (DC) = SP32 CMD 2: Lowering valve 2/2-poppet bypass valve 12 V (DC) = SP32 CME * Throttle valve and lowering valve required for version H; not available for version Q 2.5 "Motor" 2.4 "Pump" 2.3 "Tank size" 2.2 "design" 2.1 "Basic type and size"
Open the catalog to page 52.1 Basic type and size Type exclusively with DC motor Lifting version, with direct current One ow direction, with direct current One ow direction, with direct current or alternating current 2.3 Tank size Coding Usable volume (l) horizontal Usable volume (l) vertical 2.4 Pump Miniature external gear pump Coding
Open the catalog to page 6Nominal voltage For A4D and B2D: Combination with tank size 1 not possible.
Open the catalog to page 73.1 General data Installation position Horizontal or vertical (tank on top) Firmly screwed, 2 x M6 on the equipment rack preferably elastic suspension Pump design External gear pump Noise level (distance 1 m, decoupled attachment) Hydraulic uid Hydraulic uid, according to DIN 51 524 Parts 1 to 3; ISO VG 10 to 68 according to DIN ISO 3448 Viscosity range: 10 - 500 mm2/s Other media on request Cleanliness level Environment: approx. -15 to +80 °C, hydraulic uid: +10 to +40 °C Environment: approx. -30 to +80 °C, hydraulic uid: -15 to +80 °C Pay attention to the viscosity range Service life 10...
Open the catalog to page 83.3 Pressure and volumetric ow max. Operating pressure Filter retention rate 3.4 Electrical data Motor C2D Voltage Nominal power Duty cycle Electrical connection Protection class Terminal assignment Temperature measurement Rotation direction of the motor shaft: left (looking at the shaft) Characteristic line Sp operating pressure (bar); Q delivery ow (lpm); I current consumption (A)
Open the catalog to page 9rated otput duty cycle* up to 40 % (depends on je nach delivery ow, pressure, environmental condition) electrical connection protection class Terminal assignment Rotation direction of the motor shaft: left (looking at the shaft) Characteristic line pump A, C, E Sp operating pressure (bar); Q delivery ow (lpm); I current consumption (A) HAWE Hydra
Open the catalog to page 10Nominal power duty cycle* up to 40 % (depends on je nach delivery ow, pressure, environmental condition) electrical connection protection class Terminal assignment Rotation direction of the motor shaft: left (looking at the shaft) 1 2 Characteristic line pump A, B, C Sp operating pressure (bar); Q delivery ow (lpm); I current consumption (A)
Open the catalog to page 11Nominal power duty cycle* up to 40 % (depends on je nach delivery ow, pressure, environmental condition) electrical connection protection class Terminal assignment Rotation direction of the motor shaft: left (looking at the shaft) 1 2 Characteristic line pump A, B, C, D Sp operating pressure (bar); Q delivery ow (lpm); I current consumption (A)
Open the catalog to page 12Nominal power duty cycle* up to 40 % (depends on je nach delivery ow, pressure, environmental condition) electrical connection cables with ferrules protection class Terminal assignment Rotation direction of the motor shaft: left (looking at the shaft) 1 2 3 4 brown black blue yellow/green Characteristic line pump A, B Sp operating pressure (bar); Q delivery ow (lpm)
Open the catalog to page 13rated output duty cycle* up to 40 % (depends on je nach delivery ow, pressure, environmental condition) electrical connection 1 x M6 and 1 x M8 for eyelet, 1 x 6.3 x 0.8 for at push-in receptacle protection class Terminal assignment Rotation direction of the motor shaft: left (looking at the shaft) 1 2 Characteristic line pump X, D, E Sp operating pressure (bar); Q delivery ow (lpm); I current consumption (A)
Open the catalog to page 14All dimensions in mm, subject to change. A 065 - Q ... C2D Coding Tank size
Open the catalog to page 15hydraulic connections P and T: 2x M10x1 or ange port Coding Tank size
Open the catalog to page 16Coding Tank size
Open the catalog to page 17hydraulic connections P and T: 2x M10x1 or ange port Coding Tank size
Open the catalog to page 18hydraulic connections P and T: 2x M10x1 or ange port Coding Tank size Coding Motor
Open the catalog to page 19hydraulic connections P and T: 2x M10x1 or ange port Coding Tank size
Open the catalog to page 20Coding Tank size
Open the catalog to page 21Installation, operation and maintenance information DAMAGE Reference to other document Assembly instructions for mini hydraulic power pack type A: B 6025 Available for this product: assembly instructions with notes on ■ ■ ■ intended use, operating and maintenance, Assembly information HAWE Hydraulik
Open the catalog to page 22HAWE Micro Fluid GmbH Borsigstraße 11 | 93092 Barbing | Germany Phone +49 89 379100-6000 | [email protected] | www.hawe.com hawe.com/contact
Open the catalog to page 2321 Pages
15 Pages
54 Pages
17 Pages
25 Pages
45 Pages
23 Pages
88 Pages
35 Pages
6 Pages
15 Pages
23 Pages
68 Pages
41 Pages
4 Pages
13 Pages
15 Pages
34 Pages
60 Pages
20 Pages
4 Pages
12 Pages
8 Pages
42 Pages
17 Pages
19 Pages
60 Pages
30 Pages
51 Pages
12 Pages
23 Pages
47 Pages
17 Pages
14 Pages
35 Pages
35 Pages
71 Pages
299 Pages