Catalog excerpts

Compact hydraulic power pack type HICON Product documentation Operating pressure pmax: Geometric displacement volume: Usable volume (tank) Vuse max:
Open the catalog to page 1
© by HAWE Hydraulik SE. The reproduction and distribution of this document as well as the use and communication of its contents to others without explicit authorization is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of patent or utility model applications. Brand names, product names and trademarks are not specifically indicated. In particular with regard to registered and protected names and trademarks, usage is subject to legal provisions. HAWE Hydraulik respects these legal provisions in all cases. HAWE Hydraulik cannot provide...
Open the catalog to page 2
Overview of compact hydraulic power pack type HICON Compact hydraulic power packs are a type of hydraulic power pack. They are characterised by a highly compact design, since the motor shaft of the electric drive also acts as the pump shaft. Compact hydraulic power packs are designed to supply hydraulic circuits with hydraulic uid. The compact hydraulic power pack type HICON’s encapsulated design offers protection against temporary immersion in water according to protection class IP 67. The pump module integrates a gear pump and a brushless motor. The motor's rotation can be reversed, thus...
Open the catalog to page 4
Available versions Ordering example HICON 1E Pressure setting (A/B side), ex-works setting only Volume ow rate limit (A/B side) without surface coating IP 67 Electrical connection: free cable end (ferrules) with 1 m cable ■ ■ 2.2 "Pump" 2.1.3 "Installation position" 2.1.2 "Tank size" 2.1.1 "Basic type and size" 1 = size, E = brushless DC motor 2.1 Motor and container 2.1.1 Basic type and size Type Motor version 2.1.3 Installation position Coding
Open the catalog to page 5
2.2 Pump Miniature external gear pump Coding Permissible pressure pmax (bar)
Open the catalog to page 6
3.1 General data Installation position horizontal (mounting ange on side, hydraulic port on top) vertical (tank on top, mounting ange on side, hydraulic port on side) Operating pressure Tank pressure Bursting pressure Pressure limitation via valves separately for A and B side from 20 to 170 bar in increments of 10 bar (tolerance +10 bar) Pump design Gear pump Hydraulic uid Hydraulic uid, Titan CHF 11S or Titan CHF 202 Viscosity range: 10 - 500 mm2/s Cleanliness level Environment: approx. -25 to +77°C, hydraulic uid: -40 to +70°C, ensure correct viscosity range Service life Vibrations,...
Open the catalog to page 7
at: supply voltage 12 V DC, room temperature, viscosity 46 mm²/s, tolerance ± 10% at: supply voltage 24 V DC, room temperature, viscosity 46 mm²/s, tolerance ± 10%
Open the catalog to page 8
3.4 Electrical data Rated voltage Current consumption Overload protection Duty cycle Continuous operation: Intermittent operation: Intermittent operation: Intermittent operation: Protection class Software control CAN bus: Flow rate limit A and B side 0.5 to 3.0 lpm, separately to 0 to 100% open ow through A or B, when running Hardware control two signal lines for 12 V or 24 V for ow through A or B WH - signal 12 V/24 V GN - signal 0 V GY - signal GND WH - signal 12 V/24 V port A ow, port B GN - signal 12 V/24 V port B ow, port A GY - signal GND WH - signal 0 V GN - signal 12 V/24 V GY -...
Open the catalog to page 9
All dimensions in mm, subject to change. Coding Tank size Filler screw Oil level gauge CAN bus line Analogue signal GND (0 V) Analogue signal CLOCKWISE (12 V/24 V) Analogue signal ANTI-CLOCKWISE (12 V/24 V) Power supply - (GND) Power supply + (PLUS) 3x G 1/8" with plastic sealing screw
Open the catalog to page 10
Filler screw with oil dipstick CAN bus line Analogue signal GND (0 V) Analogue signal CLOCKWISE (12 V/24 V) Analogue signal ANTI-CLOCKWISE (12 V/24 V) Power supply - (GND) Power supply + (PLUS) 3x G 1/8" with plastic sealing screw Coding Tank size
Open the catalog to page 11
Installation, operation and maintenance information DAMAGE Reference to other document Assembly instructions for compact hydraulic power pack type HICON: B 8543 Available for this product: assembly instructions with notes on ■ ■ ■ intended use, operating and maintenance, Assembly information HAWE Hydraulik
Open the catalog to page 12
Other information
Open the catalog to page 13
HAWE Hydraulik SE Einsteinring 17 | 85609 Aschheim/Munich | P.O. Box 11 55 | 85605 Aschheim | Germany Phone +49 89 379100-1000 | info@hawe.de | www.hawe.com hawe.com/contact
Open the catalog to page 14All HAWE Hydraulik SE catalogs and technical brochures
-
VR
15 Pages
-
BVE
54 Pages
-
SLC
17 Pages
-
BNG
25 Pages
-
BA
45 Pages
-
Valve banks type BWN and BWH
23 Pages
-
VB
88 Pages
-
VP
35 Pages
-
VH
6 Pages
-
SL1
15 Pages
-
NBVP 16
68 Pages
-
EM
41 Pages
-
CR
4 Pages
-
BVG 1
13 Pages
-
SMD
15 Pages
-
EDL
34 Pages
-
PSLF
60 Pages
-
PS
20 Pages
-
HSF
4 Pages
-
SWS
12 Pages
-
NSWP 2
8 Pages
-
SG
42 Pages
-
K61N
17 Pages
-
K60N
19 Pages
-
V30D
60 Pages
-
V80M
30 Pages
-
V30E
51 Pages
-
RZ
12 Pages
-
Radial piston pump type R, RG
23 Pages
-
C40V
47 Pages
-
Mini hydraulic power pack type A
23 Pages
-
HR 080
17 Pages
-
INKA
35 Pages
-
FXU
35 Pages
-
ROLV
23 Pages
-
V60N
71 Pages
-
Product catalogue
299 Pages